video corpo

GENIUN PC ASP MD
1 / 2Páginas

{{requestButtons}}

Extractos del catálogo

GENIUN PC ASP MD - 1

Anti-Roots ARS Experience against the root intrusion. 5 Anti-clogging DS TECHNOLOGY The patented security. A Uniformity SILITEC Pharmaceutical technology on the dripper’s heart, the membrane. A Protection H.E.X. Exclusive triple 3D filtration system. D6Technology Anti-dogging eflidency Eficada arrtiobturante www.azud.com What it is Advantages AZUD GENIUN is the dripline, that complies with ISO 9261 specifications, that guarantees the uniform crop growth under any type of terrain, using fewer resource and totally respectful with the environment. Its self-compensating and anti-suction technology presents itself as the best solution for subsurface drip irrigation, since it prevents the particles intrusion into the dripper. Application • Subsurface drip irrigation • Irrigation of ecologic production crops. • Irrigation of extensive crops. • Irrigation of horticultural crops. • Drippers always protected: Self-cleaning H.E.X. filtration system, for surface and in-depth solid particles retention. • Uniform discharge rate guaranteed along the crop lifecycle: The inyected membrane is dynamic, which guarantees a precision, reliable and durable pressure-compensated operation and an efficient self-cleaning of the labyrinth. • Maximum strength against clogging, certified: The self-cleaning labyrinth DS Technology is made up by elliptical cavities that prevent solid particles deposits. • Higher protection against root intrusion: The ARS system consists of a balance between two arches with different opening angles and a conical design at the water emission point that make root intrusion difficult.

Abrir la página 1 del catálogo
GENIUN PC ASP MD - 2

www.azud.com AZUD GENIUN PC ASP Model AZUD GENIUN PC ASP Model AZUD GENIUN PC ASP Dripline length* Spacing between emitters* Nominal Inlet M0del thickness pressure SISTEMA AZUD, S.A reserves thengHHKhange tnSharacteristics of these products without prior notice. *Slope: 0% *Minimum pressure in the last dripper of the lateral: 0.4 bar / 6 psi. It is recommended to design the installation with lateral lengths shorter than 800 For other lateral lengths please, check AZIS, our software of hydraulic calculation meters / 2.625 feet. in www.azud.com. STRAIGHT VALVE STRAIGHT COUPLING BARBED...

Abrir la página 2 del catálogo

Todos los catálogos y folletos técnicos AZUD

  1. HTV VALVES

    2 Páginas

  2. MODEL HRV-W

    2 Páginas

  3. AZUD DLOG

    2 Páginas

  4. AZUD SYRA

    2 Páginas

  5. CNL

    2 Páginas

  6. AZUD AGL

    2 Páginas

  7. AZUD MODULAR 300

    2 Páginas

  8. AZUD SPIRAL CLEAN

    2 Páginas

  9. AZUD HELIX SYSTEM

    2 Páginas

  10. AZUD LUXON LXE

    2 Páginas

  11. AZUD LUXON LDB

    2 Páginas

  12. AZUD LUXON MFE

    2 Páginas

  13. AZUD LUXON LCA

    2 Páginas

  14. AZUD LUXON MFH

    2 Páginas

  15. FBC

    1 Páginas

  16. FT200 AA DLP

    6 Páginas

  17. AZUD modular 100

    2 Páginas

  18. AZUD GREENTEC

    2 Páginas

  19. AZUD TUB

    2 Páginas

  20. GENIUN PC ASP MD

    2 Páginas

  21. AZUD GENIUN PC MD

    2 Páginas

  22. AZUD LINE

    2 Páginas

  23. MBTECH

    2 Páginas

  24. Azud drip

    2 Páginas

  25. AZUD PC-SYSTEM

    2 Páginas

  26. AZUD PREMIER PC

    2 Páginas

  27. PREMIER PC AS

    2 Páginas

  28. AZUD PRO

    2 Páginas

  29. AZUD SPRINT

    2 Páginas

  30. NAVIA

    2 Páginas

  31. AZUD FIT

    2 Páginas

  32. FIT PLUS

    2 Páginas

  33. QGROW BS

    1 Páginas

  34. QGROW V

    1 Páginas

  35. AZUD QGROW AT500

    1 Páginas

  36. AZUD SEDAN

    2 Páginas

Catálogos archivados

  1. AZUD PREMIER HCNL

    2 Páginas