Extractos del catálogo

PUMPS, SPRAY NOZZLES, AND, ACCESSORIES PRODUCT CATALOG
Abrir la página 1 del catálogo
Selecting the Right Pump Centrifugal Pumps Life Guard Silicon Carbide Pump Seals Centrifugal Pump Accessories Transfer Pumps Roller Pumps Roller Pump Kits & Accessories Other Pump Accessories Diaphragm Pumps Diaphragm Pump Accessories, Kits and Control Units Shurflo Pumps Shurflo Diaphragm Pumps Shurflo Diaphragm Pump Accessories and Fittings Shurflo Mini-Bulk Chemical Transfer Systems and Accessories Piston / Plunger Pumps and Hydraulically-Driven Pressure Washers Specialty Pumps (Versa-Twin, Noryl, Hydraulic-Driven Gear Pump and Aqua-Tiger) PowerPro Gasoline Engines Spray Nozzles...
Abrir la página 2 del catálogo
Versa-Twin: transferring liquids in carpet cleaning, pest control, and turf spraying Noryl: bulk transfer of fertilizer and agricultural chemicals Aqua-Tiger: general pumping applications where a flooded intake is provided
Abrir la página 3 del catálogo
SELECTING THE RIGHT PUMP Because the pump is the “heart of the liquid system” on equipment, careful consideration must be made in selecting the right pump. Seldom is there only one pump that will do the job. To make a wise choice, you will need to know about pump types, how the pump is driven, and the flow and pressure requirements for your specific spraying system and application. PUMP TYPES To ensure you can closely match the pump to your needs, Pentair manufactures six different types of pumps under the Hypro and Shuflo brands: centrifugal, transfer, roller, diaphragm, piston and plunger...
Abrir la página 4 del catálogo
Diaphragm Pumps (positive displacement) Diaphragm pumps are designed to isolate abrasive and corrosive solutions being pumped from its mechanical drive components through the use of synthetic diaphragms. Diaphragm pumps are compact, self-priming and produce low-to-high pressures 0 to 725 psi (0-50 bar) with flow rates of 3.8 to 65.7 gpm (14.5 -260 lpm). Driven by 540 rpm PTO, gas engine, or hydraulic motor, diaphragm pumps are used for a variety of agricultural, horticultural and pest control spraying applications. Shurflo pumps are efficient, 12 VDC electric motor driven low pressure...
Abrir la página 5 del catálogo
SELECTING THE RIGHT PUMP PUMP DRIVES How a pump is to be driven is often a primary consideration in selecting the proper type of pump. If the power source has already been determined, the following chart may be of further help in selecting the type of pump that is best suited to your needs. HOW DO YOU PLAN TO DRIVE THE PUMP? If your power source is: direct coupled: through gear drive: through belt/pulley: Hydraulic Motor through belt/pulley: Electric Motor through gear reduction: direct coupled: through belt/pulley: direct coupled: Gas Engine through belt/pulley: through gear drive:
Abrir la página 6 del catálogo
FLOW AND PRESSURE REQUIREMENTS Pump pressure required is often dependent on the application. Whether it be low pressure band spraying or high pressure tree spraying, it is the application that dictates what pressure is needed to get the right performance at the spray nozzle. Once you know what pressure is desired choose a pump with extra pressure capacity due to losses in pressure as it goes through the system components (strainer, valves, elbows, hose, etc.) out to the nozzle. HOW MUCH PRESSURE DO YOU NEED? Pressure Shurflo Diaphragm HYPRO Diaphragm Pump flow required is dependent on...
Abrir la página 7 del catálogo
SELECTING THE RIGHT PUMP Determining Pump Flow and Pressure Requirements Every pumping task has an optimum volume and pressure requirement. Determining that optimum (and selecting the pump that delivers it) is key to an efficient and economical spraying system operation. Pressure requirements for agricultural pumps are dependent on both the material to be applied and application targets. Soilapplied herbicides generally require a relatively low pressure pump rating of 30-60 psi with foliar-applied herbicides at the top end of that range and slightly higher. Insecticides and fungicides can...
Abrir la página 8 del catálogo
Factor in an “Excess Flow” Requirement It is wise to have some excess flow capacity so you will not end up with an undersized pump because actual operation conditions may cause changes in spray system performance (such as normal pump wear, operating at less than rated speeds, etc.). Hypro recommends you add an additional 20% to your calculated total pump flow requirement to compensate for these variables. Plumbing systems have a number of restrictions that will result in a pressure drop from the pump to the actual spray point. These must be taken into account and minimized. Calculating Pump...
Abrir la página 9 del catálogo
SELECTING THE RIGHT PUMP Calculating Pump Flow for Hand Gun Spraying For low-level spraying with a hand gun, such as for lawn and turf care, professional applicators typically “walk” the lawn at about 1,000 sq. ft. per minute or 100 sq. m per minute. That means the “gpm” or “lpm” rate of the hand gun will generally be the same as “gallons per 1,000 sq. ft.” or “litres per 100 sq. m.” To Determine Your Total Pump Flow Requirement: Litres Flow required for gun/nozzle: per 1,000ft2 (same as gpm) Flow required for agitation: + gpm Litres Flow required for gun/nozzle: per 1,000ft2 (same as gpm)...
Abrir la página 10 del catálogo
SELECTING THE RIGHT SPRAY PUMP SYSTEM HOOK-UPS Centrifugal Pumps ProClean Tank Rinse Nozzle Vent Line Agitation Line Rinse Valve Bypass Control Valve Section Control Valves UF Clamps & Gaskets Line Strainer Electro Magnetic Flow Meter Cleanload Chemical Induction ProFlo Nozzle Bodies & Spray Nozzles SYSTEM HOOK-UPS Roller, Diaphragm Pumps ProCap Tank Lid ProClean Tank Rinse Nozzle Rate Controller Console Jet Agitator Suction Strainer Section Control Valves Ball Valve Pump Bypass Control Valve Tank Rinse Line Strainer Express End Cap Proportional ControlValve Pressure Relief Valve...
Abrir la página 11 del catálogo
SYSTEM HOOK-UPS Diaphragm Pumps, High Pressure Applications ProCap Tank Lid Line from Relief Valve Vented to Top of Tank to Atmospheric Pressure (Bypass Port) Line Strainer Shut-off Ball Valve Outlet to Hose Reel and Spray Gun (High Pressure Port) Outlet to Jet Agitator (High Pressure Port) SYSTEM HOOK-UPS Small Twin® Piston Pumps Spray Gun Filled Pressure Gauge Compound Gauge Pulsation Dampener Pump Line Strainer Pressure Regulator attaches here Unloader Valve Bypass back to inlet Hypro carries all parts labeled above. Please contact your local Hypro dealer by using the "Where to Buy"...
Abrir la página 12 del catálogoTodos los catálogos y folletos técnicos Pentair (Hypro & Shurflo)
-
HYPRO ® SPRAY NOZZLE SELECTION GUIDE
1 Páginas
-
GuardianAIR* TWIN
4 Páginas
-
2015 HYPRO SPRAYING GUIDE
4 Páginas
-
CROP SPRAYING POCKET GUIDE 2016
56 Páginas