Estratti del catalogo

PREG-ALERT PRO® INSTRUCTIONS (Rev. 3)
Aprire il catalogo a pagina 1
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 For clarity and uniformity, we have given all metric measurement in millimeters (mm), even though in some cases the common practice may be to use centimeters (cm). To convert to cm, divide millimeters by 10. For the same reasons we have omitted inch conversions in many cases. To convert mm to inches, divide mm by 25.4 or multiply by .04. Note that In all cases and for all readings, measurements can be indicated in either mm or inches. QUICK START CONTROLS AND FUNCTIONS ON/HOLD OFF: Press to turn instrument on. To turn on with backlight, hold key for...
Aprire il catalogo a pagina 2
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 must be displayed. The selected measurement system will be used for all measurements. LOIN: Use OPTION key to select the low range, 50-140mm or the high range 90 to 180mm. For both FAT and LOIN measurements, indications to right of the vertical marker are suppressed, thus mitigating extraneous information. PREGNANCY: Use OPTION key to select, COW, PIG, SHEEP or OTHER. Note: The ruler scale division markers on the several pregnancy screens represent different intervals and are just for reference. To see the actual distance from the skin to particular...
Aprire il catalogo a pagina 3
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 The probe must make good contact with the skin—air bubbles will block ultrasound. A coupling fluid such as cooking oil, must be used to enable good contact. Apply the coupling fluid liberally to the skin, probe or both. Press the probe to the skin, using a rotating-rocking motion, such that all air bubbles are removed. The number one problem in using ultrasound instruments is lack of good skin contact. We repeat, Ultrasound will not pass through air bubbles! USING THE PREG-ALERT PRO In order to use the instrument efficiently and with the best...
Aprire il catalogo a pagina 4
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 Table 1: Approximate distances to near and far points of the uterus for various animals at the gestation times shown. Pigs & Goats Cattle Alpacas Sheep Horses Llamas Miniature Horses Miniature Cattle The above table is only a guide the purpose of which is to give the user some feel for the distances involved. In use, the important thing to look for is a strong high spike or group of spikes in the area of interest as displayed on the screen. Pregnancy can be determined either by sensing the fetus or the interface between the amniotic fluid and the far...
Aprire il catalogo a pagina 5
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 DISPLAYS (Note: The fine ruler divisions are not shown in the displays below. The SENS setting is for illustration only.) PREG OTHER BAT PREGNANCY: SCREEN FOR OTHER SMALL-MEDIUM MAMMALS Above are several screen shots illustrating the typical displays for various functions. In the Pregnancy: OTHER screen, the dotted vertical line is the vertical marker, which the user can set to indicate the distance of any spike from the skin surface. The heavy solid vertical line is representative of the actual reading. This might in fact be multiple closely spaced...
Aprire il catalogo a pagina 6
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 display, will switch to a second LOIN (low range) screen, which providing a range of 50140mm. (Pressing the OPTION key again switches to the 90-180mm display.) (Measurements would appear in inches if the OPTION key had been used to select inches, when the FAT screen was displayed.) TESTING AND TEST SITES As an instrument manufacturer, we are primarily instrument people and not animal people. While we have done some development, much of the site information provided below is taken from the literature. The Preg-Alert Pro can be used with so many...
Aprire il catalogo a pagina 7
PREG-ALERTPRO® INSTRUCTION MANUAL Rev.3 11/28/2009 Fat and Loin Measurement sites for Swine SCAN THIS AREA Pregnancy Test Site for Swine Begin Testing swine on right side and if not pregnant, try again on the left side. Testing can begin at 18 days, testing every day until positive readings are obtained 2 days in a row. Accuracy is greatest at 30 days.
Aprire il catalogo a pagina 8
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 Pregnancy Test Site for Sheep Top figure illustrates test site for very early checking at 25 days. Bottom figure illustrates use at 35+ days. Test on left side if not successful. It may be necessary to remove wool and dirt from test site. Pregnancy Test Site for Alpacas Begin testing alpacas on the LEFT side at about 45 days. Test on the right side if not successful. After 60 days, test on right side first.
Aprire il catalogo a pagina 9
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 1. Alternate probe placement for later in gestation 7-9 months. Aiming upward into the abdominal cavity 2. For early pregnacy, aim diagonally across the pelvic cradle. (Upper shaded area.) As gestation progresses, tilt the probe by changing pressure on its top , so as to scan downward into the abdominal cavity. (Lower shaded area.) (The white circle represents the probe.) Early pregnancy probe placement. Aim at 45° across body to a point halfway between the hip bone and the pin bone. Pregnancy Test Site for Cows: Side and Top Views Refer to the three...
Aprire il catalogo a pagina 10
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 Pregnancy Test Site Mares: Side View Pregnancy Test Site for Mares: Left: Side View Right: Back View Referring to the three pictorials for mares, place the Deep probe on the LEFT flank area directly below the hip and in line with the bottom of the vulva. Aim slightly back and across ©2009 Renco Corporation
Aprire il catalogo a pagina 11
PREG-ALERT PRO® INSTRUCTION MANUAL Rev.3 the body and scan as shown. Side View Position #1 is for very early detection at around 1430 days. This a “sliding scale” and as gestation progresses you should move the probe downwards within the area shown by the outline in the side view. Side View Position #2 is for use after approximately 90-100 days and the Standard probe may be used. Pregnancy Test Site: Goats Begin testing at around 30-40 days, on the RIGHT side, 2 inches (5cm) in front of the rear leg and 1 inch (2.5cm) above teat. If not successful test again on the left side. It may be...