カタログの抜粋

KIT HYDRA 590 and CB9 COMPUTER FOR SPRAYERS
カタログの1ページ目を開く
This product complies with EMC requirements in accordance with Directives 2004/108/EC and subsequent amendments and reference to Applied Regulation EN ISO 14982 Fiesso Umbertiano (ROVIGO) - ITALY Tel. +39 0425 754713 Fax +39 0425 741130 E-mail: mcstaff@mcelettronica.it Internet: www.mcelettronica.it Manual code Issued Edition MC elettronica S.r.l. is not obliged to give notice of any further modifications to the product. The Information provided in this manual does not allow unauthorised personnel to tamper with the product in any way. The guarantee on the equipment will no longer be valid...
カタログの2ページ目を開く
1. Rules and general warnings 1.1 Introduction This manual gives all the specific information that you need for a proper use of the equipment. After buying the instrument, read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations. Keep the manual on the machine. If this is not possible, keep it ready at hand. ALL RIGHTS RESERVED. THIS MANUAL IS INTENDED FOR CUSTOMERS ONLY. ANY OTHER USE IS FORBIDDEN.
カタログの5ページ目を開く
1.2 Terms of guarantee • SUBJECT OF THE GUARANTEE: the guarantee is applied to the product and to those parts which are marked with the serial number or any other identification number used by MC elettronica; • HOW LONG THE GUARANTEE IS EFFECTIVE: MC elettronica guarantees the KIT HYDRA 590 and CB9 and its accessories for a period of |l year|from the manufacturing date (printed on the identification plate on the back of the Monitor). The guarantee covers the product and any repair carried out within the agreed terms. The guarantee does not apply in the event of: • accidental damage; •...
カタログの6ページ目を開く
2. General description The HYDRA 590 system is designed to be installed on self-propelled or towed sprayers, and is used to: • • • • • Check the product dosing and automatic and manual distribution Check the opening and closing of the section valves on the machine, up to 9 sections Check the section bar movement, up to 5 usable movements Check the air sleeve speed, with 2 user programmable speeds. Connect to a GPS guidance system to automatically close sections and prescription maps (Avmap, Trimble) The computer only works with an ECU Water/Oil Hydra control unit, code 20CEN-HYDRA-0001.
カタログの7ページ目を開く
2.1 Installation instructions with 7 sections additional module Proceed with the installation of the Kit Hydra590 / CB9 as described below: • Secure the main ECU (20CEN-HYDRA-0001) as close as possible to the water section valves in a vertical position and so that the connectors are arranged on the RH and LH as in the photo Secure the extra oil ECU (20CEN-0006 / Caffini version CFN-CEN-0001) close to the previous Main ECU in a vertical position with the connector facing downwards Secure the Hydra590 / CB9 monitor and the 7 sections oil command (20COM0001 / Caffini version CFN-COM-0001) in...
カタログの8ページ目を開く
• The S.Seal 4-way must be connected to the S.Seal connector left free of the CAN_BUS cable coming from the 7m monitor (CAB-0037 / Caffini version CFN-CAB-0007 x 13m or CAB-0036 / Caffini version CFN-CAB-0006 x 7m) A Warning Pay particular attention to connect this last described cable to the 7-sections additional oil ECU (20CEN-0006 / CFN-CEN-0001) • Finally, check that the SW ver 0.05 or higher is loaded in the main ECU. To check it enter the Hydra590 / CB9 menu and read the installed version at the top right of the blackened bar; if it is not present, proceed with the update Notes:...
カタログの9ページ目を開く
The cable 20CAB-HYDRA570-0006 coming from the main ECU and the CAB-0038 / CFN-CAB-0001 cable coming from the 7-section ECU must be connected to the respective EV according to the table below:
カタログの10ページ目を開く
4 Figure 1 The front panel allows the user to view all the data relating to the working cycle. The following elements can be seen on the panel: 1. 2. 3. 4. 5. 6. 7. 8. 9. Menu: To enter the programming menus and then return to the initial screen. ESC: To go back one screen in the programming menus. Lock: To lock and unlock hydraulic functions. F1-F2-F3-F4-F5-F6: Keys associated with the corresponding function shown on the display. Arrow keys: RH, LH, UP, DOWN menu navigation keys. OK: enter key. A/M: Automatic / manual dosing key. General: spraying start / stop. ON/OFF: system switch-on and...
カタログの11ページ目を開く
3. Air sleeve: if the icon is visible, the air sleeve is on. 4. GPS automatic closing: if the icon is visible, automatic closing is active. 5. Lock: if visible, oil sections cannot be enabled. 6. Tank: Content left in the tank. 7. Various information: Nozzle being used (visible if pressure mode active), linear metres treatable with the content left, hectares treated with the content left, hourly output
カタログの12ページ目を開く
3.3 Function keys part 1 (water) F1 F2 F3 F4 F5 F6 • F1= (function in sequence every time you press the key) air sleeve activation speed1> speed2> air sleeve switch-off. • F2= (function in sequence every time you press the key) sequentially disables sections towards the right, starting with the first active on the Lh • F3= (function in sequence every time you press the key) sequentially enables sections towards the left, starting with the first inactive on the Rh • F4= (function in sequence every time you press the key) sequentially enables sections towards the right, starting with the...
カタログの14ページ目を開く
3.4 Function keys part 2 (oil) F1 F2 F3 F4 F5 F6 • F1= enables or disables mechanical lock double-acting hydraulic valve (active = icon in the negative, inactive = icon in the positive). Opens via > arrow keys, and closes via < arrow keys (Fig. 4). • F2= enables or disables LH bar double-acting hydraulic valve (active = icon in the negative, inactive = icon in the positive). Opens via > arrow keys, and closes via < arrow keys. (Fig. 4). • F3= enables or disables RH bar double-acting hydraulic valve (active = icon in the negative, inactive = icon in the positive). Opens via > arrow keys, and...
カタログの15ページ目を開くMC Elettronica srlのすべてのカタログと技術パンフレット
-
GLM KIT
36 ページ
-
SOLID CONTROL MCK 2000
48 ページ
-
HIGH-TECH SYSTEMS
8 ページ
-
AIR VALVE LB 100 NG
1 ページ
-
MAXISEEDER PHOTOCELL