video corpo

R10 & R10 Turbo
1 / 8ページ

{{requestButtons}}

カタログの抜粋

R10 & R10 Turbo - 1

The R10 and R10 Turbo are part of the Nelson Rotator® family of sprinklers.

カタログの1ページ目を開く
R10 & R10 Turbo - 2

agricultural sprinkler matches the dependability an Ultra Reliable Low-Volume Sprinklers Filling the need for small, low-volume sprinklers that perform reliably in the mid-range between micro and a regular size sprinkler, Nelson R10 and R10 Turbo (R10T) Rotators are right on target. Incorporating the same proven, patented drive principle and advanced sprinkler technology used in other Nelson Rotators, the R10 and R10T are making their mark in a wide variety of orchard and field irrigation applications. R10 & R10 Turbo Components Rotor Plate R10 or R10T Rotator® Body Threaded Version A...

カタログの2ページ目を開く
R10 & R10 Turbo - 3

CROP APPLICATIONS Overhead cooling for tree crops. Under canopy irrigation for tree crops. For irrigation of field crops. The R10T Rotator® is used as part of a portable irrigation system that utilizes polyethylene pipe for laterals in combination with the Nelson FT5 feedtube assembly.

カタログの3ページ目を開く
R10 & R10 Turbo - 4

R 10 NOZZLE OPTIONS AND FLOW REGULATION 10FC with high pressure Nelson 10FC Flow Control Nozzle The 10FC nozzles illustrated above are operating at the same flow. As pressure increases, the flexible flow washers reduce the orifice opening size and emit a constant flow over a wide range of pressure. They assure uniform application of water throughout your crop. 10FC nozzle and 2TN nozzle flow rates with changes in pressure Why use Flow Control Nozzles? · constant flow over a range of pressure increases field uniformity low cost, high value Flow control nozzles (10FC) are an excellent low...

カタログの4ページ目を開く
R10 & R10 Turbo - 5

R10 Plate/Nozzle Options and Flow Performance in GPM and LPH Plate Series Plate Options Within the recommended pressure range of 25-50 PSI (1.75-3.25 BAR), the .35 10 FC flow control nozzle is flow regulating within a flow range of no more than 0% greater and 10% less than the nominal flow of .35 GPM (79.5 LPH). Within the recommended pressure range of pressure range of 25-50 PSI (1.75-3.25 BAR), the .5 10 FC flow control nozzle is flow regulating within a flow range of no more than 0% greater and 10% less than the nominal flow of .5 GPM (114 LPH). R10 Turbo Plate/Nozzle Options and Flow...

カタログの5ページ目を開く
R10 & R10 Turbo - 6

R 10 and R10 TURBO MOUNTING OPTIONS and ACCESSORIES Nelson Rotator® Feedtube Assemblies These versatile stake mounting options feature durable, UV and kink resistant flexible PVC tubing. Fast, simple installation. Easy nozzle cleaning — kink the tubing to stop the flow. Low cost, high value. 5 mm and 10 mm tubing options are available. See the Nelson Rotator® Feedtube Assemblies brochure for further details. FT2 Feedtube #9726-024 6 mm Steel Stake 24” (61 cm) or #10040-018 6 mm Fiberglass Stake 18” (45 cm) or #10040-024 6 mm Fiberglass Stake 24” (61 cm) ½ PVC-5 mm Feedtube R10T, Acme Base...

カタログの6ページ目を開く
R10 & R10 Turbo - 7

10 mm Feedtube Assemblies The ¾ PVC-10, FT4 and FT5 Feedtube Assemblies all utilize 10 mm feedtube and connect R10 & R10 Turbo Rotators to polyethylene laterals. The ¾ PVC-10 is a heavy-duty option that prevents damage caused by equipment, workers and animals chewing on tubing. The FT4 is for permanent connection while the FT5 has a quick connect and disconnect feature for portable lateral systems. Both assemblies are mounted with steel stakes. With the addition of collar #9195 to FT4 or FT5, they can be converted to mount on a 3/4” PVC stake. ¾ PVC-10 mm Feedtube R10T, Acme Base #11429 PVC...

カタログの7ページ目を開く
R10 & R10 Turbo - 8

NELSON OVERLAP SOFTWARE Overlap Color Contour Output (details of this typical example) Product: R10, P2 9° Red Plate, #50 2TN Nozzle Spacing: 28 x 16' (8.5 x 4.9 m) triangular, Trees 7 x 16' (2.1 x 4.9 m) Precipitation Rate: .10 in./hour (2.5 mm/hour) Uniformity is calculated for specific areas defined as Field, Strips, and Trees. Field includes everything, Strips are bands (for this example 6' (1.8 m) wide) that encompass the trees, and trees are circles (6' (1.8 m) in diameter for this example) that represent theoretical root zones. Nelson Overlap Computer Software Package (#3001)...

カタログの8ページ目を開く

Nelson Irrigation Corporationのすべてのカタログと技術パンフレット

  1. PART-CIRCLE

    4 ページ

  2. TRASHBUSTER

    2 ページ

  3. S10 SPINNER

    2 ページ

  4. D10 SPRAY

    2 ページ

  5. MP ROTATOR® 800

    2 ページ

  6. NELSON VALVES

    16 ページ

  7. Regulator Brochure

    2 ページ

  8. R55VT Brochure

    2 ページ

  9. A3030 ACCELERATOR

    2 ページ

  10. R55VT

    2 ページ

  11. Irricad Pro

    4 ページ

  12. Big Gun® Brochure

    24 ページ

  13. MP Rotator

    8 ページ

  14. TWIG

    4 ページ

  15. P85AS

    2 ページ

  16. Regulation

    2 ページ

  17. R2000 Windfighter

    4 ページ

  18. R 2000

    8 ページ

  19. R5 Rotator

    4 ページ

  20. Series 3030

    2 ページ

  21. Orbitor

    2 ページ

  22. Rotator R3030

    2 ページ