video corpo

EXHAUST FANS
1 / 12ページ

{{requestButtons}}

カタログの抜粋

EXHAUST FANS - 1

EXHAUST FANS FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS

カタログの1ページ目を開く
EXHAUST FANS - 2

Exhaust fan specifically designed for high airflow capacity. Available in 42’’ and 53’’, their main features are great efficiency and low maintenance costs. The fan housing is available in galvanized or stainless steel (Aeternum EWS 53 only) for the maximum corrosion resistance. The entire line is tested in our PERIlab and certified by BessLab. Choice of two patented opening systems FLAP SYSTEM Closed shutter Exclusive opening Open shutter CENTRIFUGAL SYSTEM Closed shutter Conventional opening

カタログの2ページ目を開く
EXHAUST FANS - 3

Effective protection from light and air thanks to the gaskets, which guarantee a perfect closure of the blades SK optional external safety netting Fixing threaded bush (M8) Bottom panel with 4 practical water discharge holes Easy opening guards Pre-tensioned V-belt Propeller hub in steel with corrosion protection Plastic safety guard on drive belt (CA optional)

カタログの3ページ目を開く
EXHAUST FANS - 4

Technical features EOS / EWS 42 - test number Bess Lab: 12324; 12321; 12317; 12320 Tested according to ANSI/AMCA 210-07 ANSI/ANSHRAE 51-07 complying with ASABE/S565 OCT 2005. *Single phase motors, different voltage and speed regulable motors over transformers are available on request. Note: All fans tested with shutter and protection net. - EOS/EWS 53/2 - EOS/EWS 53/1,5 - EOS/EWS 53/1 — EOS/EWS 53/2 [W] — EOS/EWS 53/1,5 [W] — EOS/EWS 53/1 [W]

カタログの4ページ目を開く
EXHAUST FANS - 5

Performance diagrams - EOS/EWS 42/1 - EOS/EWS 42/0,75 — EOS/EWS 42/1 [W] — EOS/EWS 42/0,75 [W] Dimensions and loading possibilities Dimensions Loading possibilities on pallet Loading possibilities Fully assembled Knock-down Measurement surface according to UNI EN ISO 3744 pic C.7 The weight depends on chosen configuration.

カタログの5ページ目を開く
EXHAUST FANS - 6

DIRECT DRIVEN EXHAUST FAN EWD exhaust fan is available in 26’’, 31’’ and 37’’. The direct drive ensures a greater efficiency by reducing energy losses. The patented centrifugal opening system guarantees a complete shutter opening already at 40% of the nominal rotation speed. Thanks to the completely redesigned opening system of EWD fans, the noise level has been reduced and the fan efficiency has been increased. The wallhousing is available in galvanized or stainless steel (Aeternum 31’’ only) for the maximum corrosion resistance. Bottom panel with 4 practical water discharge holes...

カタログの6ページ目を開く
EXHAUST FANS - 7

Technical features *Measurement surface according to UNI EN ISO 3744 pic C.7 Tested according to ANSI/AMCA 210-07 ANSI/ANSHRAE 51-07 complying with ASABE/S565 OCT 2005. *Single phase motors, different voltage and speed regulable motors over transformers are available on request only on EWD 26. Note: All fans tested with shutter and protection net. Dimensions and loading possibilities Dimensions^^^^^^^l EWD 26 EWD 31 EWD 37 Loading possibilities on pallet EWD 26 EWD 31 EWD 37

カタログの7ページ目を開く
EXHAUST FANS - 8

Exhaust fan with air outlet cone in the version 53s". Thanks to the “Venturi effect” the fan can achieve a very high efficiency and a reduction of operational costs. Wallhousing and shutter blades in galvanized steel ensure high corrosion resistance even in very aggressive environments. The fan has been tested in our PERIlab and certified by BessLab. Sturdy and pratical motor fixing system Removable shutter blades for easy maintenance/inspection ABT Adjustable belt tensioner (optional) Bottom panel with practical water discharge holes. Security grid on the squared cone NT Safety net on air...

カタログの8ページ目を開く
EXHAUST FANS - 9

Dimensions and loading possibilities GOC The cone special shape, which has the same outer dimensions of the fan’s body, permits to install more EOC 56 in comparison to similar products. Body in galvanised steel, propeller and shutter blades in aluminium alloy guarantee the necessary protection also in harsh environments. Tested in our PERIlab. *Fan body and shutter are delivered pre-assembled, whereas the cone (in sectors), brackets and front cone safety nets are delivered separately in flat pack form.

カタログの9ページ目を開く
EXHAUST FANS - 10

Technical features Model Ventilating Efficiency Ratio (25 Pa - 0.10 inHO)

カタログの10ページ目を開く
EXHAUST FANS - 11

Shutter versions • wall installation All data in this catalogue are indicative and are subject to change without prior notice.

カタログの11ページ目を開く
EXHAUST FANS - 12

TEHMDTECNICn PEPICDLI Release - July 2023 TERMOTECNICA PERICOLI S.r.l. Regione Rapalline, 44 - 17031 Albenga, Italia tel. 0182 589006 fax 0182 589005 pit@pericoli.com PERICOLI ASIA PACIFIC Sdn. Bhd. pap@pericoli.com PERICOLI CENTRO AMERICA pca@pericoli.com PERICOLI MIDDLE EAST pme@pericoli.com PERICOLI INDIA Pvt. Ltd. pin@pericoli.com pericoli.com OBSESS' 68 P€R/coo/ are registered trademarks by Termotecnica Pericoli S.r.l.

カタログの12ページ目を開く

TERMOTECNICA PERICOLIのすべてのカタログと技術パンフレット

  1. EOD 56c

    2 ページ

  2. ACF 21-26p

    4 ページ

  3. EOD

    8 ページ

  4. PLAScool

    4 ページ

  5. G-LINE

    8 ページ

  6. ACCESSORIES

    12 ページ

  7. COOLING

    12 ページ

  8. DIRECT HEATING

    8 ページ

  9. INDIRECT HEATING

    8 ページ

  10. AIR CIRCULATION FANS

    12 ページ