video corpo

Ceiling Inlet

Ceiling Inlet

Ceiling Inlet

Product catalog summary
Overview
The Loft Inlet MPI is designed for negative pressure ventilation systems, ensuring optimal air intake and distribution in stables without causing drafts. The system is crucial for mixing fresh air with stable air efficiently while minimizing energy consumption.

Materials and Design
The inlet is made from dimensionally stable, UV-stabilized polystyrene, which is environmentally friendly and resistant to cleaning agents. Its smooth design allows for easy cleaning with high-pressure cleaners.

Benefits
  • Stable design with reinforced frame
  • Excellent performance in cold conditions
  • Single flap model fits all loft thicknesses
  • Competitive pricing

Installation
The inlet is mounted to the ceiling using screws and sealed with silicone or similar materials. It features a modular system with a basic module of 90 mm and additional 90 mm adapters to match loft thickness.

Operation
The flap opens downwards automatically and can be locked in place. A nylon chord is used for manual operation. The system ensures safety by allowing the flap to open in case of wire system failure.

Technical Specifications
  • Loft inlet heights: 90 mm, 180 mm, 270 mm
  • Output at -10Pa: 1320-1440 m3/h
  • Output at -20Pa: 1870-2015 m3/h
  • Standard dimensions: 650 mm length, 90 mm height, 260 mm width

Additional Features
  • Quick and easy mounting
  • Rounded edges for easy cleaning
  • Air distribution plate to prevent turbulence
  • Insulating core to prevent condensation
See more

Catalog excerpts

Ceiling Inlet-1

Product Leaflet Loft inlet MPI Loft inlet for negative pressure ventilation systems The loft inlet is designed to regulate intake air in all stable types with negative pressure systems. The purpose of the system is to mix fresh air with the air in the stable without causing draught problems for the animals within the stable. The positioning of the fresh air intake is therefore the most important aspect when installing a good ventilation system. At the same time, the distribution of air must be optimal throughout the entire stable and the system must have the lowest possible energy consumption. Materials The inlet is fabricated in polystyrene. It is dimensionally stable and UV stabilized. The open, smooth design ensures rapid cleaning using, for example, a high-pressure cleaner. Benefits • Stable design with reinforced frame • Extremely stable in cold conditions • Highest resistance to cleaning agents • Environmentally-friendly material, polystyrene • 1 standard size as picture with a hight of 90 mm • Adapter to increase hight 90 mm. • Single flap model • Fits all loft thicknesses • Competitive price Positioning of inlets The loft inlet is fastened to the ceiling with screws, and seal up at the edge using silicone or another type of sealing material. Product description The inlets are available in a module system consisting of a basic module of 90 mm plus one or more 90 mm adapters which can be connected consecutively such that they match the thickness of the loft. The flap is infinitely adjustable and is retained by means of a locking system. The inlet flap opens downwards unaided, which means that the flap is closed by pulling it up. This provides the highest degree of safety since the flap will always open if there should be a fault in the wire system. A nylon chord is fitted at a central lifting point in order to open and close the flap. Owing to the negative pressure in the stable, fresh air is sucked in through the inlet and is then distributed in the stable according to the settings of the individual flaps. The inlet is completely sealed when in

 Open the catalog to page 1
Ceiling Inlet-2

Technical specifications Quick and easy mounting Air distribution plate prevents turbulence Easy cleaning. Rounded edges 90 mm adapter can increase the hight to 180 mm The flap is made up of two parts, which ensure geometrical stability Insulating core prevents condensation Air distribution plate. Optimum air Standard dimensions: Standard loft inlet Length Output: Loft inlet hight: Output m3/h at compl. open -10Pa Output m3/h at compl. open -20Pa

 Open the catalog to page 2

All ACO Funki A/S catalogs and technical brochures

  1. FLEXCOVER

    2  Pages

  2. Funkiflex

    2  Pages

  3. MASTER HEATER

    8  Pages

  4. 2020 COMPONENTS

    52  Pages

  5. 2020 FINISHERS

    48  Pages

  6. 2020 WEANERS

    48  Pages

  7. WELSAFE FLEX

    2  Pages

  8. FT-30 pen

    2  Pages

  9. Pen equipment

    2  Pages

  10. Aqua Drop

    1  Page

  11. Agrosilo

    2  Pages

  12. DRIK-O-MAT

    2  Pages

  13. Dry Feeding

    16  Pages

  14. LD-box

    2  Pages

  15. COMBI FLOOR

    16  Pages

  16. CLEAN-O-FLEX

    2  Pages

  17. Pig Center

    2  Pages

  18. Star Diffuser

    2  Pages

  19. Curtains

    1  Page

  20. Full Line

    20  Pages

  21. Ventilation

    8  Pages

  22. Combi-feeder

    2  Pages

  23. FUNKI FLEX

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.