Overview: The GM500 is a 500Kg waste incinerator specifically designed for medical waste. It is marketed as one of the most thermally efficient, robust, and reliable incinerators available. The incinerator is suitable for medical, clinical, and pathological waste categories 0 to 2.
Specifications: The GM500 features a primary loading chamber and a secondary afterburner chamber, ensuring clean combustion at temperatures between 850-1150°C. It has an internal chamber volume of 1m³ and is capable of handling waste with moisture content between 70-100%. The incinerator is CE certified and compliant with EU regulations.
Construction: The incinerator is constructed with a robust mild steel casing and features a fully insulated internal refractory lining. The primary and secondary chambers have a lining thickness of 180mm, rated at 1750°C, enhancing fuel efficiency and durability.
Emissions and Fuel: Emissions testing shows results well below EC limits. The incinerator uses diesel, LPG, or natural gas as fuel, with a composition of 86% carbon, 13.2% hydrogen, and 0.7% nitrogen.
Key Features: The GM500 includes a programmable logic controller with a touch screen interface, data logging, and temperature feedback. It also features an emergency stop, security lockout, and cycle status indicators.
Waste Handling: The incinerator is designed for top loading through the main access door. It is essential to implement bio-security measures due to the nature of the waste. Ash is discharged through the loading door after each incineration process.
Applications: Suitable for incinerating medical waste such as faeces/blood-stained materials, cancer treatment wastes, surgery waste, syringes/needles, and mattresses.
See more

Catalog excerpts

Addfield GM500 Medical Waste Incinerator Datasheet GA PLC-1

‘The most thermally efficient, robust and reliable animal incinerators on the market Simply Built Better!’ 500Kg Waste Incinerator Specifically designed for Medical waste Our mid range low capacity medical incinerator, extremely robust with a pre-cast block abrasion/impact resistant seal to prevent damage through mechanical loading. The GM500 is ideal for medical, clinical and pathological category 0 to 2 type waste. With an internal chamber volume of 1m3, the GM500 ensures even the largest material can be loaded fast and efficiently. Complete with an excess air systems that maintain a constant burn rate up to 50kg per hour cleanly and efficiently every time. addfield Incinerate • Cremate t: +44 (0)1543 571280 | f: +44 (0)1543 571173 e: [email protected] | www.addfield.co.uk Addfield Environmental Systems Limited Hollies Park | Cannock | Staffordshire | WS11 1DB | UK

 Open the catalog to page 1
Addfield GM500 Medical Waste Incinerator Datasheet GA PLC-2

The medical GM range is designed as a two stage incinerator unit comprising of a primary loading chamber and a secondary after burner chamber. This afterburner system draws the hot gases from the primary chamber, this ensures a clean (and compliant) burn at temperatures of 850-1150°C. t Based on general municipal waste streams * Depending on the type waste stream being loaded and excludes heat up time. Fuel Input Diesel Composition % Carbon We reserve the right to change the specification, dimensions and quality of materials from time to time, so long as the alteration is minor or an improvement...

 Open the catalog to page 2
Addfield GM500 Medical Waste Incinerator Datasheet GA PLC-3

Secondary Chamber • Fully insulated internal refractory lining, constructed from high grade low thermal mass insulation. • One secondary chamber burnout burner, temperature controlled on-off, complete with internal air fans • Integrated combustion burner air fans with automatically controlled distribution to their designated area. • One temperature sensor mounting point at the top of the chamber ensuring the chamber reaches the necessary 1100°C minimum. 500Kg Waste Incinerator Specifically designed for Medical waste Key Features: We have CFD modelled all of our incinerators by utilising some...

 Open the catalog to page 3
Addfield GM500 Medical Waste Incinerator Datasheet GA PLC-4

500Kg Waste Incinerator Specifically designed for Medical waste Addfield Programmable Logic Controller Key Features: Waste Loading and De-Ashing The medical GM series of incinerators are designed for top loading only through the main access door. Due to the type of wastes they incinerate, bio-security measures should be in place on the site of the incinerator due to the possibility of spillage and spread of disease. At the end of every incineration process ash should be discharged through the loading door onto the supplied catcher tray prior to being loaded for the next burn. Waste types to be...

 Open the catalog to page 4
Addfield GM500 Medical Waste Incinerator Datasheet GA PLC-5

FLOOR PLAN 150mm concrete base Chimney Sections Control Panel PLAN VIEW GENERAL ARRANGEMENT OF GM500 INCINERATOR Unit 17 Hollies Park Cannock ISOMETRIC VIEW

 Open the catalog to page 5

All Addfield Environmental Systems catalogs and technical brochures

  1. RAPID1000

    4  Pages

  2. MINI AB

    3  Pages

  3. MINI

    3  Pages

  4. MINI PLUS

    3  Pages

  5. SB

    3  Pages

  6. TB

    3  Pages

  7. MINI AB AQUA

    4  Pages

  8. THUNDER 500

    3  Pages

  9. MP-500

    3  Pages

  10. GM350

    5  Pages

  11. GM250

    5  Pages

  12. TB-AB PET

    3  Pages

  13. TB PET

    3  Pages

  14. CREMULATOR

    2  Pages

  15. A50-IC (2)

    3  Pages

  16. AES100-2SEC

    5  Pages

  17. LABMASTER 25

    4  Pages

  18. RAPID1000

    6  Pages

  19. TBAB-MAX

    5  Pages

  20. C300

    5  Pages

  21. PetCremation

    6  Pages

  22. MP-100

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.