Catalog excerpts

Hydraulic self-cleaning screen filters, Flltomat M100/MG Filters with no external powe? source required flow rates M100: up to 400 m3/h (1,760 gpm) MG: up to 800 m3/h (3,520 gpm) minimum operating pressure less than 1% of the total flow filtration degrees features: • Reliable operating mechanism • Simple construction and easy maintenance • Ideal solution for agricultural filtration requirements • Automatic flushing according to pressure differential • No interruption of downstream flow during flushing • High reliability and durability • Hydraulic or electronic control
Open the catalog to page 1
How the Filtomat Filters Work General The Amiad Filtomat M100 and MG Series are automatic, self-cleaning filters, ideal for remote installation sites, with a water-driven self-cleaning mechanism that doesn’t require an external power source for operation. With a variety of screen areas the M100 and MG models support flow rates of up to 3,520 gpm (800 m3/h), with filtration degrees of 500 down to 80 micron and inlet/outlet diameters from 2” to 14”. The Filtration Process The filtration process begins when raw water flows through the filter inlet into the coarse screen which pre-filters the...
Open the catalog to page 2
M100 Models Available as a stand alone or as filter bank assembly, with a single control system (AC/DC). Amiad's Filtomat M100 Series consists of the following models: M100-750 for up to 40 m3/h (176 gpm) M100-1500 for up to 80 m3/h (350 gpm) M100-2250 for up to 100 m3/h (440 gpm) M100-4500 for up to 180 m3/h (793 gpm) M100-6800 for up to 400 m3/h (1,760 gpm) MG Models Modular configuration, available as a stand alone or as filter bank assembly, with a single control system (AC/DC). The MG modules are delivered fully assembled, requiring a single connection to the inlet, outlet and drain....
Open the catalog to page 3
Typical Dimensional Drawing Head Loss Graphs (in clean water) *Approx. length required for maintenance
Open the catalog to page 5
Typical Dimensional Drawing Head Loss Graphs (in clean water) *Approx. length required for main
Open the catalog to page 7
Typical Dimensional Drawing Head Loss Graphs (in clean water) PSI 14.0 *Approx. length required for mainten
Open the catalog to page 9
* Amiad offers a variety of construction materials. Consult us for specifications.
Open the catalog to page 10
* Amiad offers a variety of construction materials. Consult us for specifications.