Technical Data Summary
High Temperature Probes
Articles: HTS04FLD80, HTS04FLD100
Article Numbers: 0001203, 0001204
Application Purpose: These probes are designed for temperature measurement in processes with multiple measuring points, specifically within the chemical industry.
General Information:
- Material Housing: Aluminium casting, dimensions 100 x 100 x 80mm
- Material Connection: AISI 316L-W1.4404/1.4435 V2A
- Sensor Tube: AISI 316-W.1.4401 V2A MgO - sheathed cable 4.5mm
- Number of Sensors: Max. 11 for HTS04FLD80, Max. 16 for HTS04FLD100
- Weight: Housing 8.4kg (HTS04FLD80), 8.5kg (HTS04FLD100); Sensors approx. 70g per sensor per meter
- Tensile Load Sensors: Max. 10kN
Functional Data:
- Operating Principle: Analogue temperature probe
- Sensor Type: MgO - sensor tube Pt10’000, Pt1000, Pt100
- Bending Radius Sensor Tube: 22.5mm
- Length Sensor Tube: 0.1m to 30m
- Measuring Range: -99°C to 400°C
- Accuracy: Class B (DIN EN 60751)
- Process Connection: DN80 PN16 for HTS04FLD80, DN100 PN16 for HTS04FLD100
- Process Pressure: Max. 16 bar
Electrical Data:
- Connection: 2-wire / 3-wire / 4-wire
- Max. Sensor Current: Pt 10'000: 100uA, Pt 1000: 500uA, Pt 100: 1mA
- Connection Data for Intrinsically Safe Systems: Ui: max. 10VDC (Gas-Ex: max. 1.5VDC), Ii: max. 250mA, Pi: max. 15mW / sensor, Li: max. 300uH, Ci: max. 200nF
Temperature Range:
- Max. Housing Ambient Temp.: -20°C to +90°C
- Max. Housing Surface Temp.: -20°C to +90°C (T5), -20°C to +120°C (T4)
- Process: -50°C to +90°C (T5), -50°C to +125°C (T4), -50°C to +190°C (T3), -50°C to +285°C (T2)
- Max. Temperature Increase: 5K / sensor
- Storage: -20°C to +60°C (max. 2 years)
Safety Relevant Data:
- IP Protection Class: IP66 (housing) / IP68 (sensor tube)
- ATEX Certification: 2-wire / 3-wire Ex II 1/2D Ex ta/tb IIIC T290°C Da/Db
See more