1. Catalogs
  2. Agromatic AG
  3. Scanbox ADT-D 512 ATEX

Scanbox ADT-D 512 ATEX

Scanbox ADT-D 512 ATEX

Scanbox ADT-D 512 ATEX

Product catalog summary
Technical Specifications
  • Product Name: Scanbox ADT-D 512
  • Article Numbers: 1030040 (ATEX), 1030041 (zone free), 1030044 (ATEX), 1030045 (zone free)
  • Application: Manages energy and data recording for digital temperature measuring cables.
  • Housing: Steel, powder-coated, dimensions 200 x 150 x 80mm, max weight 3kg.
  • Zone Allocation: Zone 22 or zone free.

Connections
  • 8 ports for 64 measuring points each.
  • 2x Agro Serial data cable ports.
  • 1x internal and 1x external equipotential bonding.
  • Cable glands: M16.

Functional Data
  • Measuring Method: 2-wire digital.
  • Measuring Range: Min. -20°C to +50°C, max. 99°C.
  • Max Cable Length: 300m / 64MS per port.
  • Process Pressure: 0.8 to 1.1bar.

Electrical Data
  • Operating Voltage: 48VAC or 230VAC.
  • Power: Max. 200mW.
  • Output Voltage: Max. 6.8VDC.
  • Output Current at Short-Circuit: Max. 120mA.
  • Potential Separation: Min. 1500V.

Temperature Range
  • Ambient: -20°C to +60°C.
  • Process: -20°C to +55°C.
  • Storage: -20°C to +60°C, max. 2 years.

Safety and Certification
  • Protection Class: I.
  • IP Protection Class: IP65.
  • ATEX Certification: 1030040: Ex II 1D Ex taD IIIC, 1030044: Ex II1D Ex taD IIIC.

Mechanical Data
  • Wiring Diagram: Includes connections for ADT data bus and temperature measuring cable.
  • Switches and Indicators: Terminator-Switch, Address-Code, Power LED (green), Data LED (red).
  • Fuses: F1, F2, F3 - 100mAT each.

Important Note

Please read the operating instructions before setting the unit to operation.

See more

Catalog excerpts

Scanbox ADT-D 512 ATEX-1

Technical Data Scanbox ADT-D 512 Agromatic AG, Goldingerstr. 30, 8637 Laupen, Switzerland, Phone +41 (0)55 256 21 00, www.agromatic.com

 Open the catalog to page 1
Scanbox ADT-D 512 ATEX-2

S ) blank L1) white-blue L2) blue A ) white-yellow B ) yellow measuring cable) Fuse 100mAT Fuse 100mAT Fuse 100mAT S1: Terminator-Switch S2: Adress-Code L2: Power led (green) L1: Data led (red) Documents download Bedienungsanleitung Important Please read the operating instructions before setting the unit to operation! Agromatic AG, Goldingerstr. 30, 8637 Laupen, Switzerland, Phone +41 (0)55 256 21 00, www.agromatic.com

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.