video corpo

AL SA-100
32Pages

{{requestButtons}}

Catalog excerpts

AL SA-100 - 1

AIR PURIFICATION AND DISINFECTION SYSTEMS USER MANUAL

Open the catalog to page 1
AL SA-100 - 2

AL SA-100 Photocatalytic Air Purifier User Manual Airlife Swiss AG Manufacturer Kharis Musaleev Adrian Gubser Document type: Technical document Revisions Index First edition Third edition Airlife Swiss AG Sarganserstrasse 44

Open the catalog to page 2
AL SA-100 - 3

Overview of the Air Purifier SA-100 Description of the main Components Technical Specifications 54000-10-0001 - User Manual - Final (3).docx

Open the catalog to page 3
AL SA-100 - 4

Intended use We would like to thank you for purchasing the product of Airlife Swiss AG. This manual is an integral part of the product and must be provided to the customer at the point of purchase. This user manual applies to the photocatalytic air purifier AL SA-100 (hereinafter – air purifier, product, device) designed for purification of air of any types of microbiological contaminants (mold spores, viruses, bacteria), dust, solid and liquid aerosols, any types of allergens, unpleasant odors, and toxic substances. The air purifier can be used continuously indoors in the presence of...

Open the catalog to page 4
AL SA-100 - 5

Contents The shipping contains the following items: No. Item Designation User/Maintenance Manual Transport Packing Please, check the contents of the package before use. If any items are missing or damaged, please contact the supplier or manufacturer. The contact information is provided on the front page of this user manual. Danger IT IS PROHIBITED to use the air purifier if the housing, power cord, power plug is damaged. 54000-10-0001 - User Manual - Final (3).docx

Open the catalog to page 5
AL SA-100 - 6

Design and Technical Specifications Description of the main Components 1. Pre-filter – removes dust and particles larger than 15 μm in size. 2. Aerosols charging unit – ensures a symmetrical electrostatic field inside the element and 99.9% filtration efficiency for particles between 0.1 and 100 μm in size. 3. Combined polarized adsorption-photocatalytic filter – traps the particulates up to 0.1 μm in size, adsorbs unpleasant odors, toxic chemical substances, allergens, viruses, bacteria, etc. The technology allows using the polarized filter as a precipitator for charged particles. The...

Open the catalog to page 6
AL SA-100 - 7

photocatalyst oxidizes micro-organic substances, volatile organic compounds, and allergerns to harmless components – carbon dioxide, water and atmospheric nitrogen. 4. UV-A emitter – UV-radiation provides energy for activation of the photocatalyst. The device is equipped with UV-lamp with the wavelength of 320400 nm (spectrum A). 5. Fan – Ensures circulation of air from the room through the unit and its filters. 54000-10-0001 - User Manual - Final (3).docx

Open the catalog to page 7
AL SA-100 - 8

Technical Specifications Parameter, units Recommended location area of operation, m 2 Filtration efficiency against aerosols, % Rated input power, W 14 Noise level, dBa 15 Shelf life, years (chapter 9.1) 16 Degree of protection provided by enclosure 54000-10-0001 - User Manual - Final (3).docx

Open the catalog to page 8
AL SA-100 - 9

Placement of the Product SA-100 must be positioned to stand vertically on an even base. The device has wheels on the bottom for portability. All four wheels can be locked for convenience. Place the device so that the furniture has the minimal impact on the course of air flow. The best level of air purification is achieved near the device. Therefore, it’s recommended to place the device close to workstation or near sources of problematic particles to prevent spreading. Attention Placing the device on its side and tilting is PROHIBITED during operation. Do not cover ventilation holes with...

Open the catalog to page 9
AL SA-100 - 10

Plug the device into a grounded 230V socket. Switch on the device using the air supply controller (Fig. 1) by turning it clockwise. Set the required level of air supply. The continuous work time is unlimited. SA-100 takes in the contaminated air from the bottom and let purified air out through the upper part of the unit. The device effectively collects contaminants on the filters inside it. Danger Air purifier CANNOT BE used for the purposes different from the intended purpose, stated in the user manual. IT IS PROHIBITED to use the device in humid environments with relative air humidity...

Open the catalog to page 10
AL SA-100 - 11

No. 1: Air Supply Controller No. 2 Shielded Enclosure 4.3 Turning the product ON after a long Break in Operation A “sour” smell may occur in the purified air when it is turned on after long breaks. This is not a malfunction and associated with gas adsorption on the surface of a photocatalyst in the absence of UV-radiation. After a short time of operation, the photocatalyst self-cleaning takes place and the smell disappears. 54000-10-0001 - User Manual - Final (3).docx

Open the catalog to page 11
AL SA-100 - 12

Emergency Situations The most likely emergency events are: − − presence of unusual noise; foreign objects or water penetration inside the device; disconnection from the ground. Attention In the presence of faults (for example, burning smell), immediately switch off the device! Contact the manufacturer for the following advice. In case of an emergency situation, the air purifier must be immediately switched off and completely disconnected from the power! In case of emergency, the following actions should be taken: 1. 2. 3. 4. 5. Unplug the device from the outlet. Provide first aid to the...

Open the catalog to page 12
AL SA-100 - 13

Maintenance, Repair and Replacement The owner of the device is allowed to carry out maintenance. Due to safety reasons, repair shall be carried out by a person authorised by the manufacturer. Chapter 6.2 provides detailed maintenance description, which can be done by the owner. In case of questions regarding maintenance, repair or replacement, contact the manufacturer (chapter 6.1). Danger IT IS PROHIBITED to introduce any unauthorised changes to modifications and construction of the product. IT IS PROHIBITED to perform maintenance while the power is on. Switch off the device and unplug the...

Open the catalog to page 13
AL SA-100 - 14

Maintenance includes the following procedures: − − − − keeping the housing clean outside; cleaning the aerosols charging unit; replacement of an UV-A emitter (lamp) once it depletes its resources; replacement of filters. Change/Clean Interval Latest after 2 Years Latest after 6 Months Combined polarized adsorption-photocatalytic filter Latest after 6 Months Aerosols charging unit Latest after 6 Months The filters must be replaced once they become clogged. Their untimely replacement may lead to the air purifier overheating and failure, as well as to its reduce efficiency of filtration and...

Open the catalog to page 14

All Airlife swiss catalogs and technical brochures

  1. AL-C-Line

    2 Pages