Akvasmart Sensors
29Pages

{{requestButtons}}

Catalog excerpts

Akvasmart Sensors - 1

USER MANUAL Akvasmart Sensors Oxygen - Temperature - Current tilt Corrections temperature sensor Second edition, with RDO Sensor Issued DC10000536 User manual Akvasmart Sensors

Open the catalog to page 1
Akvasmart Sensors - 2

The information in this document is subject to change without notice and should not be construed as a commitment by AKVA group ASA. AKVA group ASA assumes no responsibility for any errors that may appear in this document. In no event shall AKVA group ASA be liable for incidental or consequential damages arising from use of this document or of the software and hardware described in this document. We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Additional copies...

Open the catalog to page 2
Akvasmart Sensors - 3

User manual Akvasmart Sensors

Open the catalog to page 3
Akvasmart Sensors - 4

1 Safety Safety for the users of our equipment is top focus when AKVA group ASA develop new products and product manuals. We therefor strongly recommend that everyone that use the equipment, all that perform any type of repairs, service or other maintenance to the product, and all that work in areas where the product is installed read this entire manual and at least this safety chapter. This recommendation is based on both personnel safety as well as a desire to keep the products in order and avoid damages risked if the safety instructions are not followed. 1.1 Safety symbols used in the...

Open the catalog to page 4
Akvasmart Sensors - 5

1.2 Receiving new equipment Always check that the delivery is complete according to the service note. If the order is not complete or if any other errors are discovered, contact AKVA group immediately. AKVA group ASA provides a 1 year warranty covering manufacturer’s defects. The warranty is effective upon date of shipment to original recipient. The following are reasons for a void of warranty: - Poor treatment of the system due to negligence of preventive recommendations or from improper usage of power sources - If the sensor units are opened without express written consent of an AKVA...

Open the catalog to page 5
Akvasmart Sensors - 6

1.5 Cable Make sure that the sensor cables are never twirled! Coil them according to instructions in chapter 7. Make sure that the cable is in order, without any tears or damages, when it is connected to power. The cable must not be used if it has any bends, tears or breaks. To make sure that there is no tension to the cable when the sensor is in the water, and to avoid lifting the sensor by its cable, always use lifting ropes, one for each sensor. Instructions for these ropes are found in chapter 5.2. 1.6 Bad weather Always make sure that all of the ropes and all of the equipment are ok...

Open the catalog to page 6
Akvasmart Sensors - 7

2 Introduction This user manual is part of the equipment delivered with AKVAsmart sensors. Preserve the manual for as long as the equipment is being used, and make sure that all changes done to the equipment are being noted in this manual. Thank you for choosing AKVA group ASA as supplier for your sensor. Do not hesitate contacting us if you need more information regarding installation, use or maintenance for your product. With four main brands, AKVA group ASA is a world leading supplier of technical aquaculture equipment. Since 1980 we have developed and produced fish farming equipment,...

Open the catalog to page 7
Akvasmart Sensors - 8

Our production staff consists of people with great expertise and enthusiasm to produce the best possible products for you. Having our own production site gives you excellent service in case something should go wrong, or if you are in need of any assistance. We hold most of the parts for your equipment in stock, and our service staff is available on the telephone or on location in order to assist you if necessary. This entire manual and especially the safety chapter must be read and understood before commencing any work on the equipment. Prior to operating, repairing, performing maintenance...

Open the catalog to page 8
Akvasmart Sensors - 9

3 Sensors Controlling environmental data as temperature, oxygen level and current speed are important inputs when feeding fish. In the Akvasmart CCS Feed System, all these factors can be set to automatically control or adjust the feeding amount and its speed. All environmental data will be logged and can be used in further analyses either in AkvaControl or in Fishtalk. Accurate real time measurements are shown and logged in the control program and AkvaControl will calculate expected daily feed amount based on feeding tables and invited sensor data. The system can be wireless and signals are...

Open the catalog to page 9
Akvasmart Sensors - 10

3.1 Current sensor Two types of the current sensors: - one measuring currents from 0-50cm/sec - one larger sensor measuring currents from 0-100cm/sec Current sensor, type Measurement range Measuring principle Electronic tilt sensor Electronic tilt sensor Power consumption Amphenol (water proof, Amphenol (water proof, potted plug) potted plug) *Limited by cable length ** Including stainless steel stabiliser weight and cable User manual Akvasmart Sensors

Open the catalog to page 10
Akvasmart Sensors - 11

The Akvasmart Current sensor is one of several tools developed for the fish farming industry to optimize feeding and thereby cost benefits. The current sensor is directly connected to the Akvasmart CCS Feeding System, and signals participate in regulating the feeding rate and amount. The sensor also contribute in preventing feed from being carried out from the cage before the fish gets the chance to eat it. Sensors are placed strategically, and maximum current speed for feed termination as well as which cages are controlled by the specific sensor, is programmed. When the current exceeds...

Open the catalog to page 11
Akvasmart Sensors - 12

RDO Oxygen Sensor Accuracy: Operating temp.range Measurement range Measuring principle Optical luminescent Power consumption Amphenol (water proof) User manual Akvasmart Sensors

Open the catalog to page 12
Akvasmart Sensors - 13

Oxygen sensors are one of several tools developed for the fish farming industry to optimize feeding and thereby the fish farms cost benefits. Oxygen is an important factor for growth and fish welfare. With this sensor connected to the feeding system, feed amount may be stopped when the waters oxygen level is too low. The RDO oxygen sensor is a robust and reliable membrane free sensor whose measurements are based on optical readings. This reduces the need for calibrations, gives high accuracy degree and can be used for long periods without loss of measurement accuracy. Simple, regularly...

Open the catalog to page 13

All AKVA group catalogs and technical brochures

  1. Tubenet

    2 Pages

  2. MOORING

    1 Pages

  3. Vicass HD

    1 Pages

  4. CCS Shrimp

    2 Pages

Archived catalogs