Safety
Safety is emphasized as a top priority in the development of AKVA group ASA products and manuals. Users and personnel should thoroughly read the manual, especially the safety chapter, to ensure personal safety and prevent equipment damage. Key safety symbols include alerts, notices, and warnings for potential equipment damage or mild injuries.
Receiving New Equipment
Upon receiving new equipment, verify the delivery against the service note and contact AKVA group for any discrepancies. The equipment includes a one-year warranty for manufacturer defects, effective from the shipment date. The warranty is void if preventive recommendations are neglected or if sensor units are opened without authorization.
Plug Caps and Disinfection
Plug caps should be kept safe and replaced immediately after equipment removal to prevent moisture and saltwater damage. Equipment should be disinfected when moving between sites to prevent contamination, followed by a rinse with fresh water to avoid corrosion.
Cable Handling
Ensure sensor cables are not twisted and are coiled as instructed. Check cables for damage before connecting to power, and use lifting ropes for sensors to avoid cable tension.
Bad Weather Precautions
Inspect all equipment and ropes after storms to ensure they are intact and undamaged. Report any issues to AKVA immediately.
Introduction
This manual accompanies AKVAsmart sensors and should be preserved for the equipment's lifespan. AKVA group ASA is a leading supplier of aquaculture equipment, focusing on sustainable farming through continuous product development. The manual provides guidance for safe and economical operation of Akvasmart Sensors.
Sensors
Akvasmart sensors measure environmental data like temperature, oxygen levels, and current speed, crucial for optimizing fish feeding. The system can be wireless, with data logged for analysis in AkvaControl or Fishtalk. Correct feeding, aided by these sensors, is essential for optimal fish growth and feed efficiency.
Current Sensor
Two types of current sensors measure currents up to 50 cm/sec and 100 cm/sec, respectively. They are crucial for regulating feeding rates and preventing feed wastage. The sensors have no moving parts, ensuring longevity and minimal maintenance.
Oxygen Sensors
The RDO Oxygen Sensor measures oxygen levels with high accuracy and operates within a temperature range of 0-50°C. It uses an optical luminescent measuring principle and is designed for depths up to 210m, limited by cable length.
Oxygen Sensor Specifications
The RDO oxygen sensor is membrane-free, utilizing optical readings for high accuracy and reduced calibration needs. It operates effectively in stationary water and stores measurement data for up to a year in a replaceable cap tip. The cap has a 12-month expiration, requiring a new user code (AKVA part no. 10000855) upon expiration.
Temperature Sensor Specifications
The temperature sensor has a resolution of +/- 0.1°C and an accuracy of +/- 0.5°C, with a measurement range of 0-50°C. It is housed in machined bronze, which minimizes maintenance and provides quick response to temperature changes. The sensor can be connected to various systems for real-time monitoring and data logging.
Installation and Suspension
Proper installation involves securing sensor cables to ropes to prevent tension and marking depths with waterproof markers. Specific instructions are provided for attaching weights and ensuring secure connections.
Power Supply
Sensors are powered through connections to CSU or EAP systems. It is crucial to maintain the integrity of plug caps and connections to ensure proper operation.
Handling and Maintenance
Sensor cables should be coiled without twirling to prevent damage. Regular cleaning and inspection are recommended, especially during warmer seasons. A detailed maintenance plan outlines daily, weekly, and monthly tasks to ensure sensor longevity and accuracy.
Maintenance Plan
The document provides a structured maintenance schedule, including daily checks for cable and rope integrity, weekly cleaning, and monthly inspections for corrosion and cable wear. Maintenance forms should be copied and filled out regularly to track sensor upkeep.
Appendices
The manual includes an index, deviation form for reporting issues, and space for additional notes.
See more

Catalog excerpts

Akvasmart Sensors-1

USER MANUAL Akvasmart Sensors Oxygen - Temperature - Current tilt Corrections temperature sensor Second edition, with RDO Sensor Issued DC10000536 User manual Akvasmart Sensors

 Open the catalog to page 1
Akvasmart Sensors-2

The information in this document is subject to change without notice and should not be construed as a commitment by AKVA group ASA. AKVA group ASA assumes no responsibility for any errors that may appear in this document. In no event shall AKVA group ASA be liable for incidental or consequential damages arising from use of this document or of the software and hardware described in this document. We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. Additional copies of...

 Open the catalog to page 2
Akvasmart Sensors-3

User manual Akvasmart Sensors

 Open the catalog to page 3
Akvasmart Sensors-4

1 Safety Safety for the users of our equipment is top focus when AKVA group ASA develop new products and product manuals. We therefor strongly recommend that everyone that use the equipment, all that perform any type of repairs, service or other maintenance to the product, and all that work in areas where the product is installed read this entire manual and at least this safety chapter. This recommendation is based on both personnel safety as well as a desire to keep the products in order and avoid damages risked if the safety instructions are not followed. 1.1 Safety symbols used in the manual...

 Open the catalog to page 4
Akvasmart Sensors-5

1.2 Receiving new equipment Always check that the delivery is complete according to the service note. If the order is not complete or if any other errors are discovered, contact AKVA group immediately. AKVA group ASA provides a 1 year warranty covering manufacturer’s defects. The warranty is effective upon date of shipment to original recipient. The following are reasons for a void of warranty: - Poor treatment of the system due to negligence of preventive recommendations or from improper usage of power sources - If the sensor units are opened without express written consent of an AKVA group...

 Open the catalog to page 5
Akvasmart Sensors-6

1.5 Cable Make sure that the sensor cables are never twirled! Coil them according to instructions in chapter 7. Make sure that the cable is in order, without any tears or damages, when it is connected to power. The cable must not be used if it has any bends, tears or breaks. To make sure that there is no tension to the cable when the sensor is in the water, and to avoid lifting the sensor by its cable, always use lifting ropes, one for each sensor. Instructions for these ropes are found in chapter 5.2. 1.6 Bad weather Always make sure that all of the ropes and all of the equipment are ok after...

 Open the catalog to page 6
Akvasmart Sensors-7

2 Introduction This user manual is part of the equipment delivered with AKVAsmart sensors. Preserve the manual for as long as the equipment is being used, and make sure that all changes done to the equipment are being noted in this manual. Thank you for choosing AKVA group ASA as supplier for your sensor. Do not hesitate contacting us if you need more information regarding installation, use or maintenance for your product. With four main brands, AKVA group ASA is a world leading supplier of technical aquaculture equipment. Since 1980 we have developed and produced fish farming equipment, both...

 Open the catalog to page 7
Akvasmart Sensors-8

Our production staff consists of people with great expertise and enthusiasm to produce the best possible products for you. Having our own production site gives you excellent service in case something should go wrong, or if you are in need of any assistance. We hold most of the parts for your equipment in stock, and our service staff is available on the telephone or on location in order to assist you if necessary. This entire manual and especially the safety chapter must be read and understood before commencing any work on the equipment. Prior to operating, repairing, performing maintenance or...

 Open the catalog to page 8
Akvasmart Sensors-9

3 Sensors Controlling environmental data as temperature, oxygen level and current speed are important inputs when feeding fish. In the Akvasmart CCS Feed System, all these factors can be set to automatically control or adjust the feeding amount and its speed. All environmental data will be logged and can be used in further analyses either in AkvaControl or in Fishtalk. Accurate real time measurements are shown and logged in the control program and AkvaControl will calculate expected daily feed amount based on feeding tables and invited sensor data. The system can be wireless and signals are transferred...

 Open the catalog to page 9
Akvasmart Sensors-10

3.1 Current sensor Two types of the current sensors: - one measuring currents from 0-50cm/sec - one larger sensor measuring currents from 0-100cm/sec Current sensor, type Measurement range Measuring principle Electronic tilt sensor Electronic tilt sensor Power consumption Amphenol (water proof, Amphenol (water proof, potted plug) potted plug) *Limited by cable length ** Including stainless steel stabiliser weight and cable User manual Akvasmart Sensors

 Open the catalog to page 10
Akvasmart Sensors-11

The Akvasmart Current sensor is one of several tools developed for the fish farming industry to optimize feeding and thereby cost benefits. The current sensor is directly connected to the Akvasmart CCS Feeding System, and signals participate in regulating the feeding rate and amount. The sensor also contribute in preventing feed from being carried out from the cage before the fish gets the chance to eat it. Sensors are placed strategically, and maximum current speed for feed termination as well as which cages are controlled by the specific sensor, is programmed. When the current exceeds this...

 Open the catalog to page 11
Akvasmart Sensors-12

RDO Oxygen Sensor Accuracy: Operating temp.range Measurement range Measuring principle Optical luminescent Power consumption Amphenol (water proof) User manual Akvasmart Sensors

 Open the catalog to page 12
Akvasmart Sensors-13

Oxygen sensors are one of several tools developed for the fish farming industry to optimize feeding and thereby the fish farms cost benefits. Oxygen is an important factor for growth and fish welfare. With this sensor connected to the feeding system, feed amount may be stopped when the waters oxygen level is too low. The RDO oxygen sensor is a robust and reliable membrane free sensor whose measurements are based on optical readings. This reduces the need for calibrations, gives high accuracy degree and can be used for long periods without loss of measurement accuracy. Simple, regularly cleaning...