video corpo

TESTING TestaCal
10Pages

{{requestButtons}}

Catalog excerpts

TESTING TestaCal - 1

TESTINGTESTACAL TEMPERATURE AND HUMIDITY TESTING CHAMBER SPECIALLY DESIGNED FOR CALIBRATION, METROLOGY AND QUALITY CONTROL

Open the catalog to page 1
TESTING TestaCal - 2

TESTACAL 300 – ENVIRONMENTAL CHAMBER ARALAB is a company specialised in designing, developing, manufacturing and servicing of high quality climatic chambers and controlled environment rooms. Since 1985 we have been perfecting ways to create and control temperature, humidity, light, air flow and many other environmental conditions. Only the highest quality components are used to manufacture our chambers so customers can have the best equipment for their research and testing purposes. Control the environment, Your own climate. Aralab Testing chambers have been the preferred solution of...

Open the catalog to page 2
TESTING TestaCal - 3

TESTACAL 300 - ENVIRONMENTAL CHAMBER AVAILABLE MODELS • • • • TESTACAL TESTING CHAMBERS Performance in CLIMATIC testing range Performances measured in factory with ambient temperatures between 20°C and 25°C (1a) Measurements with empty chamber and no optional accessories; (1b) in temperature range up to 150°C; (2) According to IEC/EN 60068-3-5. Values will vary with TESTA/TESTACAL model, internal volume, compressor type and condenser cooling system. Temperature rate of change can be adjusted to comply with the needed heating / cooling speed requirements. Optional accessories are available...

Open the catalog to page 3
TESTING TestaCal - 4

TESTACAL 300 - ENVIRONMENTAL CHAMBER 40 EXTERNAL DIMENSIONS (HxWxD) (mm) 0 RS232 (or RJ45) communications port 4. 0 Water cooled option: Water flow: up to 2000 l/hr (at 25 °C) Intake pressure: 2 to 5 bar Water entry and exit pipe: 1” or 28mm Differential pressure between entry and exit: > 2,5 bars Maximum temperature of water entry: 26 °C Minimum temperature of water entry: 16 °C Recommended temperature of water entry: 18 °C 1. Standard refrigeration system is air cooled 2. Services hub installation needs: # V2” demineralized water supply # 50mm water drain at floor level 3. # Electrical...

Open the catalog to page 4
TESTING TestaCal - 5

TESTACAL 300 – ENVIRONMENTAL CHAMBER EQUIPMENT DESCRIPTION TEMPERATURE Control of temperature is done by the PLC Touch Screen “ClimaPlus”, high tech PID / FUZZY temperature and humidity control, developed by Aralab. TEMPERATURE SENSORS • One (1) PT 100 Class A, located in air treatment tunnel • One (1) PT 100 Class A, movable sensor for flexible placing inside chamber HEATING • By tubular stainless steel electric heaters located in the air treatment tunnel COOLING • By airtight mechanical Scroll compressor group with enforced ventilation and without CFC’s. • As an option the system can be...

Open the catalog to page 5
TESTING TestaCal - 6

TESTACAL 300 – ENVIRONMENTAL CHAMBER COMMON ACCESSORIES PLEASE CONSULT ARALAB FOR OTHER ITEMS FitoLog and FitoLogView Software pack Anti-condensation observation window in multi layered glass Water demineralizer Water conductivity monitor Additional entry side-ports Calibration certificates from accredited external laboratory Height leveling casters Heating / Cooling temperature change rate speeds Attachable computer for logging and chamber programs management WINDOW OPTION The observation window is composed of a multilayered glass with optimum levels of thermal insulation. The interior and...

Open the catalog to page 6
TESTING TestaCal - 7

TESTACAL 300 – ENVIRONMENTAL CHAMBER CONTROLLER CLIMA PLUS Programmable PLC exclusively developed for ARALAB chambers Easy to use coloured Touch-Screen Display Interface Resolution of 0,1ºC for Temperature and 0,1% for Relative Humidity High performance temperature and humidity control with value correction in all ranges Capability for creating 50 programs of 50 segments each Internal non volatile memory for storing test data Automatic restart of tests due to power failure, without losing data and restarting test where it was interrupted Real-time monitoring of all functions and control of...

Open the catalog to page 7
TESTING TestaCal - 8

TESTACAL 300 – ENVIRONMENTAL CHAMBER FITOLOG SOFTWARE The FitoLog software pack is a set of applications designed to facilitate the managing, monitoring and recording of programs and data from the FitoClima chambers. It consists of 3 applications: FitoLog, FitoLogView and FitoProgram. FITOLOG Records and displays in real time all data and details related to the set-points, running variables and equipment behaviour. It also retrieves information about the active components of the chamber, running processes, errors, alarms and allows the configuration of periodic or alarm triggered remote...

Open the catalog to page 8
TESTING TestaCal - 9

TESTACAL 300 – ENVIRONMENTAL CHAMBER INSTALLATION REQUIREMENTS INSTALLATION SITE The place should be easily accessible, according to equipment dimensions and weight. It should have good air circulation and a room temperature between 10º and 26ºC. The floor should be levelled and a minimum distance of 50cm from the walls and other equipment must be kept. ELECTRICAL SUPPLY Near the equipment with connection for 3/N/PE AC 400V ± 10% 50Hz 16Amp. The equipment is supplied with an ECE type power connector. The electrical panel must have a differential protection of 300 mA. WEIGHT Approximately...

Open the catalog to page 9
TESTING TestaCal - 10

Let’s meet! aralab@aralab.pt www.aralab.pt T: +351 219 154 960 Control the environment Your own climate

Open the catalog to page 10

All Aralab catalogs and technical brochures