Catalog excerpts
Manual Hydraulic Control Valve c In-line Finger Filter Description Armaş “M” model valve is the hydraulic control valve operated by line pressure and designed to ensure opening/closing process by means of 3-way selector valve. Minimum opening pressure of valve is 0.7 bar. Thanks to its flexible diaphragm, it makes easy and fast control process in high pressure applications and is closed as full tightness without causing surge. It may be used in different applications by adding different pilot valves on its main body. Installation • Make sure that valve is on a level with the pipeline while mounting it. • Mount valve in direction of arrow indicated on it. • While connecting valve on pipeline, place gasket between valve flange and pipe flange to ensure sealing and tighten the bolts as crosswise. • Mount valve body in reservoir or tank upstream and mount float components as fixed in desired level interval. • It is recommended that insulation valves (butterfly or gate valves etc.), air relief valve and strainer valves will be used in line-mounting of valve Typical Application 1 1 Manual Control Valve
Open the catalog to page 1Adjustment • Select adjustment position by means of 3-way selector valve indicated with "a"on main valve. • Valve is open in "Open"position and closed in"Close"position Maintenance • Check finger filter in valve upstream according to water quality. • Drain water within actuator of valve not used in winter.
Open the catalog to page 2All Armas Su Armaturleri San ve Tic AS catalogs and technical brochures
-