FT200 AA DLP - 1

HELIX AUTOMATIC FT200 AA DLP SELF-CLEANING DISC FILTRATION EQUIPMENT Working conditions Salinity Backwash volume Water temperature *Compressed air pressure > Water pressure Filtration degrees (micron) 400 DESCRIPTION Self-cleaning disc filtration equipment composed by 1 to 10 filters AZUD HELIX AUTOMATIC Ø2" with discs AZUD MG/ WS, which perform an in-depth 3D filtration, installed in-line on Ø2"-Ø8" inlet/outlet manifolds. Includes Ø2" backwash valves 3-way membrane type and the innovative DLP TECHNOLOGY, that enable the sequential low-pressure backwashing of each filter using a mix of filtered water and compressed air stored in an auxiliary tank, while continues the filtered water supply downstream. The patented AZUD HELIX anti-clogging deflector provides a reliable filtration thanks to an effect of centrifugal separation, with less backwash frequency and less water and energy consumption. APPLICATIONS >>Make-up water filtration >>Filtration in tanks, lakes and fonts Smart, compact and modular plug&play solution, made of technical thermoplastics, increases the shelf life of the installation providing a long-term operation with minimum operational costs and less maintenance downtime. >>Disinfection system protection >>Particles recovery >>Water reuse Avda. de las Américas P. 6/6 • Polígono Industrial Oeste 30820 Alcantarilla • Murcia - Spain • Apdo. 147 • 30169 San Ginés • Murcia - Spain Tel.: +34 968 808 402 • Fax.: +34 968 808 302 • E-mail: info@azud.com • www.azud.com SISTEMA AZUD S.A. reserves the right to change the characteristics of these products without

Open the catalog to page 1
FT200 AA DLP - 2

HELIX AUTOMATIC FT200 AA DLP HOW DO THEY WORK FILTRATION PHASE: • Water flows from the inlet manifold to the inside of the filter, passing through the anticlogging deflector AZUD HELIX, which throws the heavy particles away from the disc stack, avoiding the quick clogging of the filter and minimizing the backwash frequency. • Water flows OUT-IN through the disc stack to the outlet manifold while particles bigger than the filtration degree are trapped in the disc. SELF-CLEANING PHASE: • During the automatic backwash, a water-air mix is made, providing a more energetic and effective cleaning...

Open the catalog to page 2
FT200 AA DLP - 3

HELIX AUTOMATIC FT200 AA DLP MICRON FT201 AA DLP HEAD LOSS PER FILTRATION DEGREE* AZUD HELIX AUTOMATIC FT201 AA DLP Head loss / Pérdida de carga (bar) MANUFACTURER RECOMMENDATION The flow rate given by filter conditions the frecuency of the backflushing activation. With reference to the design, it should be taken into account the most unfavourable value of the differential of pressure. This differential value is the existing one at the beginning of the backflushing process, which corresponds with the fixed value by the user in the differential pressure gauge (normally 0.5 bar/7.25 psi)....

Open the catalog to page 3
FT200 AA DLP - 4

HELIX AUTOMATIC FT200 AA DLP MICRON FT204 AA DLP HEAD LOSS PER FILTRATION DEGREE* AZUD HELIX AUTOMATIC FT204 AA DLP gpm Head loss / Pérdida de carga (bar) Inlet pressure manifold MANUFACTURER RECOMMENDATIONthe frecuency of the backflushing activation. The flow rate given by filter conditions With reference to the design, it should be taken into account the most unfavourable value of the differential of pressure. This differential value is the existing one at the beginning of the backflushing process, which corresponds with the fixed value by the user in the differential pressure gauge...

Open the catalog to page 4
FT200 AA DLP - 5

HELIX AUTOMATIC FT200 AA DLP MICRON FT207 AA DLP HEAD LOSS PER FILTRATION DEGREE* AZUD HELIX AUTOMATIC FT207 AA DLP gpm Head loss / Pérdida de carga (bar) Inlet pressure manifold MANUFACTURER RECOMMENDATIONthe frecuency of the backflushing activation. The flow rate given by filter conditions With reference to the design, it should be taken into account the most unfavourable value of the differential of pressure. This differential value is the existing one at the beginning of the backflushing process, which corresponds with the fixed value by the user in the differential pressure gauge...

Open the catalog to page 5
FT200 AA DLP - 6

ARAB EMIRATES SOUTH AFRICA SOUTH KOREA Avda. de las Américas P. 6/6 • Polígono Industrial Oeste 30820 Alcantarilla • Murcia - Spain • Apdo. 147 • 30169 San Ginés • Murcia - Spain Tel.: +34 968 808 402 • Fax.: +34 968 808 302 • E-mail: info@azud.com • www.azud.com SISTEMA AZUD S.A. reserves the right to change the characteristics of these products witho

Open the catalog to page 6

All AZUD catalogs and technical brochures

  1. HTV VALVES

    2 Pages

  2. MODEL HRV-W

    2 Pages

  3. AZUD FIT

    2 Pages

  4. FIT PLUS

    2 Pages

  5. QGROW BS

    1 Pages

  6. QGROW V

    1 Pages

  7. AZUD DLOG

    2 Pages

  8. AZUD SYRA

    2 Pages

  9. AZUD SEDAN

    2 Pages

  10. CNL

    2 Pages

  11. AZUD AGL

    2 Pages

  12. FBC

    1 Pages

  13. AZUD TUB

    2 Pages

  14. AZUD LINE

    2 Pages

  15. Azud drip

    2 Pages

  16. AZUD PRO

    2 Pages

  17. AZUD SPRINT

    2 Pages

  18. MBTECH

    2 Pages

  19. NAVIA

    2 Pages

Archived catalogs