Bentley Instruments Brochure
17Pages

{{requestButtons}}

Catalog excerpts

Bentley Instruments Brochure - 1

BENTLEYINSTRUMENTSConsistency in Quality NexGen Series for Dairy Plants and Central Milk Testing Laboratories Innovative Analytical Solutions for the Dairy Industry DISCOVER OUR COMMITMENT TO OUTSTANDING QUALITY OF EQUIPMENT, SERVICE AND SUPPORT

Open the catalog to page 1
Bentley Instruments Brochure - 2

With BENTLEY INSTRUMENTS, opt for Customized Service, opt for Quality... Since 1982, Bentley Instruments teams offer you the possibility to rely on exceptionally accurate and robust analytical instruments. Our company is the only one of its kind to focus exclusively on the dairy industry. We developed our expertise for you. Our engineers are committed to understand, anticipate and answer your needs and challenges the best possible way.* YOUR SUCCESS IS OUR PRIORITY. *Onsite training, installation & support, as well as internet-based remote control support are provided to help you maintain...

Open the catalog to page 2
Bentley Instruments Brochure - 3

Our User-Friendly Software Our Windows based software program has a simple and intuitive graphical user interface designed for easy operator use. The software sophisticated data export and reporting functions along with network access capability allow lab supervisors to monitor instrument status and analyze results remotely. It also allows our support team to help you reactively whenever needed to maintain the highest level of productivity.

Open the catalog to page 3
Bentley Instruments Brochure - 4

SOMATIC CELLS APPLICATIONS Measuring range: Accuracy (Cv): Carry-Over: Repeatability(Cv): Type of Samples Milk of typical composition TOTAL BACTERIA 2000 to 10+ million APPLICATION individual bacteria/ml Repeatability Range (/)11} & Specifications IDF 10OB: 1991 or AOAC 9S6.33) Cow: Sy,x = 0.167 (AIA) Sheep: Sy,x = 0.245 (AIA) Buffalo: Sy,x = 0.201 (AIA) Speed Analyzing time: <1 minute Prep time: 15 seconds Incubation time: V (sccV 10' (ibc) Undiluted Work Factor 10-100 Real-time detection of milk tranker contamination before unloading. Real-time detection of milk silo...

Open the catalog to page 4
Bentley Instruments Brochure - 5

The DairySpec FT Infrared Analyser Series SEMI-AUTMOMATIC & AUTOMATIC VERSIONS 50, 100, 200, 300 samples per hour PRIMARY APPLICATIONS Determination of fat, protein, lactose, solids, urea, fatty acids profile, FFA, FPD, Blood & Milk BHB and somatic cell content in milk (up to 60 components) Highly reliable and accurate for individual tests on a variety of milk and dairy products (cream, whey, permeate, retentate...) Future proof, adaptable to measure additional metrics. Start Up/Shut Down Less than 10 minutes Measurement Range Milk Type Cow, goat, sheep, buffalo raw milk Electrical 110/...

Open the catalog to page 5
Bentley Instruments Brochure - 6

STANDARDIZATION AND QUALITY CONTROL PRIMARY APPLICATIONS Highly accurate somatic cells enumeration in raw milk. Optional automated sampling system. Analytical speed up to 300 samples per hour. SomaCount™ FC Start Up/Shut Down Less than 10 minutes Measurement Range 0-10.000.000 cells/ml Milk Type Cow, goat, sheep, buffalo raw milk Accuracy* (Cv) < 10% (against direct microscopic count) Connected to the local database and remotely accessible Specifications subject to change without any prior notice. BENTLEY INSTRUMENTS

Open the catalog to page 6
Bentley Instruments Brochure - 7

SomaCount™ FC DairySpec FT Start Up/Shut Down Less than 10 minutes Less then 10 minutes Milk Type Cow, goat, sheep, buffalo, raw milk Cow, goat, sheep, buffalo raw milk Accuracy* (Cv) < 10% (against direct Cv < 1% for all components microscopic count) Repeatability* (Cv) SCC < 500.00 < 4% Cv < 0.5% for all components Connected to the local database and remotely accessible M Flow cytometry and FTIR * Specifications subject to change without any prior notice.

Open the catalog to page 7
Bentley Instruments Brochure - 8

Start Up/Shut Down Less than 10 minutes Less then 10 minutes Milk Type Cow, goat, sheep, buffalo, raw milk Cow, goat, sheep, buffalo raw milk Accuracy* (Cv) < 10% (against direct Cv < 1% for all components microscopic count) Repeatability* (Cv) SCC < 500.00 < 4% Cv < 0.5% for all components Connected to the local database and remotely accessible M Flow cytometry and FTIR * Specifications subject to change without any prior notice.

Open the catalog to page 8
Bentley Instruments Brochure - 9

Innovative and fully automated solutions dedicated to the central laboratories for sample handling and analysis BENTLEY COMBI FTS 600 ILAS From 300 up to 600 samples per hour MAIN APPLICATIONS Measurement of fat, protein, lactose, solids, urea, fatty acids profile, FFA, FPD, Blood & Milk BHB and somatic cells in milk (up to 60 components) Spectra fully standardized (x,y) ILAS 3000 robot for complete automated sample preparation (heating, mixing, uncapping and identification)

Open the catalog to page 9
Bentley Instruments Brochure - 10

NEW COMBI FTS ILAS 4000 (60ml vials) The CombiFTS ILAS 4000 is equipped with a larger carousel to be able to handle and heat larger vials (60 ml) while maintening a speed of up to 600 samples/hour

Open the catalog to page 10
Bentley Instruments Brochure - 11

Milk of typical composition (cow, sheep, goat and buffalo) 2000 to 1Q+ million individual bacteria/ml Range (/fjL) & Specifications 10-50. Sr 0.07 log 51-100, Sr 0.06 log 101-300. Sr 0.05 log >300. Sr 0.03 log The BactoCount reapetability fully complies with ISO 16140 standard with a Sr<0.09 log Reproducibility 10-50, Sro.14 log 51-100. Sr 0.12 log 101-300, Sr 0.10 log >300, Sr 0.06 log The BactoCount Reproducibility fully complies with ISO 16140 standard with a Sr < 0.16 log Act uracy Sypc 0.30 log (ISO 4S33,1DF 100B: 1991 or AQAC 936.33) Cow: Sypt = 0.167 log Sheep: Sy,s= 0.245...

Open the catalog to page 11
Bentley Instruments Brochure - 12

Innovative and fully automated solutions dedicated to the central laboratories for sample handling and analysis BACTOCOUNT IBC (ISO 16140) & ILAS 4000 ROBOT Up to 150 samples/hour BactoCount IBC for the rapid and highly accurate determination of the total flora in raw milk (ISO 16140 certified) Available with standard linear autosampler and ILAS robot The ILAS robot is refrigerated and allows to standardize the sample preparation (identification, mixing, uncapping, recapping of the vials)

Open the catalog to page 12
Bentley Instruments Brochure - 13

COMPLETE LABORATORY AUTOMATION BENTLEY INSTRUMENTS Complete laboratory automation with the CombiFTS ILAS 4000 combined with sorter and conveyor systems. The trays are sorted out in a refrigerated area based on the analysis to be done and placed on a conveyor belt, in order of priority, to bring the samples to the first available CombiFTS ILAS 4000

Open the catalog to page 13

All Bentley Instruments catalogs and technical brochures

  1. ChemSpec_150

    2 Pages

  2. DairySpec FT

    8 Pages