house entrances- B2 - 1

Single and multi-section house entrance.

Open the catalog to page 1
house entrances- B2 - 4

Multi-section house entry for the base plate The multi-section house entry for buildings without basements offers a compact and safe complete solution for the building entry of the different trades (gas, water, electricity and telecommunications) in a common installation device for concreting into the floor slab. Gas and high pressure water proofness are ensured for each section according to DVGW VP 601. The torsion and pull-out resistance of the buried gas supply line is ensured by locking the safety clamping ring during installation of the gas division. The bending-resistant 90°...

Open the catalog to page 4
house entrances- B2 - 5

ASSEMBLY INSTRUCTIONS Multi-section house entry for the base plate 1 Select the planning position. Measure the height with an installation stand, batten if necessary. Fix the corrugated protective pipes supplied to the casing pipes of the multi-section house entry using the push-in sleeves supplied. Lubricating paste eases the installation. Close the open ends of the empty pipes using the supplied end sleeves or end plugs (gas) to prevent dirt or mud from entering. Insert with assembled protective pipes according to the specifications on the planning height dimension. Lay the protective...

Open the catalog to page 5
house entrances- B2 - 6

Multi-section house entry for the wall For buildings with basement rooms, the multi-section house entry for the wall is ideal. It offers a compact and safe complete solution for the building entry of the different trades (gas, water, electricity and telecommunications) in a common installation device. The installation is carried out in a core hole bore or a casing pipe Ø 200 mm. Gas and pressurised water tightness are ensured for each section according to DVGW VP 601. The torsion and pull-out resistance of the buried gas supply pipe is ensured by locking the safety clamping ring during the...

Open the catalog to page 6
house entrances- B2 - 7

ASSEMBLY INSTRUCTIONS Multi-section house entry for the wall 1 Clean the core bore/lining, repair any break-outs. Adjust the outer seal to the wall thickness. Tighten the pre-assembled hose clamp S with a screwdriver to prevent the seal from shifting during insertion. Insert the multi-section house entry for the wall leading from the house connection room to the outside. Now use the spirit level to determine the desired position of the multi-section house entry by means of the pegs Z. Tighten the five cylinder screws (hexagon socket) of the inner flange. Then tighten the four screws of the...

Open the catalog to page 7
house entrances- B2 - 8

Single-section house entry for the base plate The single-section house entry for buildings without basements offers a compact and safe complete solution for the building entry of different trades (gas, water, electrical and telecommunications) for concreting into the floor slab. Gas and pressurised water tightness are ensured in accordance with DVGW VP 601. The torsion and pullout resistance of the buried gas supply line is ensured by locking the safety clamping ring during installation as a gas section. The bending-resistant 90° connection bend guarantees compliance with the minimum...

Open the catalog to page 8
house entrances- B2 - 9

ASSEMBLY INSTRUCTIONS Single-section house entry for the base plate Position the earth spike with the spirit level. Next, drive the ground spike in vertically up to the appropriate height. Use the wing screw M12 to fix the single-split house entry. Information You can find the BEULCO one-size-fits-all house entries for the wall in our catalogue brochure „Wall entries - B“.

Open the catalog to page 9
house entrances- B2 - 10

BUILDER‘S SETS AUSSTATTUNG Multi-section house entries BAUHERREN-SETS Package contents of the builder‘s sets Installation in the base plate • House entry, 4 empty pipes for: - Gas DN 25 - Water Ø 32 mm / 40 mm / 50 mm - Electric Ø 20-22 mm / 26-28 mm / 31-33 mm - Telecommunication with 5 passages: Ø 7-9 mm / 9-11 mm / 11-13 mm / 15-17 mm / 19-21 mm • 1 assembly stand incl. concrete stand • 4 pcs. connection bend 90°, radius 500 mm, OD 90 mm • 4 pieces transition socket DA 75 mm to DI 90 mm for on-site connection of corrugated protective pipe DA 90 mm • Set of connection sleeves incl....

Open the catalog to page 10
house entrances- B2 - 11

BUILDER‘S SETS Single-section house entries & accessories Package contents of the builder‘s sets Installation in the floor plate • • • • • • • • House inlet with connection bend 90°, radius 500 mm, OD 90 mm pre-assembled with ground spike incl. tensioning straps Gasket set complete for water section Ø 32 mm / 40 mm / 50 mm 1 piece press flange for single section incl. screws M8x25 1 piece end sleeve for water division incl. stainless steel clamping band 20 mm / 30 mm / 40 mm / 50 mm-75 mm / 90 mm Installation instructions for single-split house entry Optional connection of corrugated...

Open the catalog to page 11
house entrances- B2 - 12

BEULCO® GmbH & Co. KG Kölner Straße 92 D-57439 Attendorn P.D. Box 1 20 D-57425 Attendorn Tel. +49 2722 695-0 info@beulco.de www.beulco.de/water 07 | 2024 Articles may differ from the illustration and are subject to technical changes. Please refer to our website for the latest information. Our general terms and conditions apply.

Open the catalog to page 12