Bird Gard SUPER PRO PA4
2Pages

{{requestButtons}}

Catalog excerpts

Bird Gard SUPER PRO PA4 - 1

I®* EsED> ■ o»o|» ■ °M°I' ■ f°l' TO' DE» TIME OFF INTERVALj TIME OF OPERATION [ ® RANDOM OPERATION 5 Digital Bird Repeller Your complete Bird Gard® Super Pro PA4 kit includes a control unit, power adapter, battery cable with clips and four separate PA-type speakers. Open the control unit by pressing backward on the two latches on the side of the box. Prior to operation, plug the power cable into the power jack on the control unit, and the four speaker plugs into the speaker jacks, then route the speaker and power cables from their respective jacks on the control panel down through the slotted rubber grommet and through the opening in the lower part of the enclosure, see Fig. 1. IMPORTANT NOTE: Be certain that the OFF - ON switch is in the OFF position and the volume control is set to the minimum (LOW) volume level (counterclockwise) as shown in Fig. 2 while plugging the speaker and power cords into the control unit. INSTALLATION 1) Use the mounting hardware (included) to mount the control unit box to a wall, post or other vertical surface. 2) Plug the power adapter into an electrical outlet or attach the battery clip assembly to a 12V battery. The other end of the cable should already be plugged into the power jack located below POWER on the front panel of the control unit box. 3) Mount the speaker(s) on a pole, post or surface that is aimed directly at the area to be covered. Speakers should be at least 1 -3 feet above the top of the crop or area to be covered. 4) Set the Recordings, Mode Settings, Time Off Interval, Time of Operation, Random and Speakers Used switches to the desired settings. (See “PROGRAMMING YOUR BIRD GARD" for complete details on how to program your bird repeller). 5) Make sure the volume setting is set to LOW (all the way counterclockwise). 6) Slide the OFF-ON power switch to the ON position. The unit may take a few seconds before starting. 7) Adjust the volume to the desired level. 8) Close the cover and latch shut. YOUR BIRD GARD® To program your Bird Gard® Super Pro PA4 unit you will need a small screwdriver, toothpick, or other small, rigid object to slide the switches in the switch array. The switch arrays are the switch banks located in the top left corner of the unit (under “RECORDINGS”). A switch is ON if the switch is moved to the right-hand side by sliding the switch to the right. The switch is OFF when moved to the left-hand side. The Recordings switches are the first eight switches in the top switch array. Each switch has a Sound number to the left of it that corresponds with the bird/sound descriptions listed on the foil label located on the EPROM board to the right of the switch arrays. Bird Gard Super Pro PA4 is designed to play each selected sound at a different randomly selected frequency each time it plays that sound. This feature is designed to add to the effectiveness of the unit and is independent of the Random Operation Switch Setting. NOTE: The Bird Gard Super Pro PA4 features a replaceable EPROM board and chip. Notice that the sounds included on your Bird Gard Super Pro PA4 unit are listed on a silver foil label affixed to the chip. To remove, simply pull EPROM board and chip straight out from the embedded socket. Then insert a different EPROM board and chip by pressing firmly straight into the socket. The Mode Settings switches are the next five switches which control the various modes of operation: such as the amount of time between playing bird distress calls, when the unit will operate (Day Only, Night Only, or 24-Hours), whether the unit will operate in the Random Mode. Switch Mode or Function 1 Sets the Time Off Interval 2 Sets the Time Off Interval 3 Sets the Time the unit plays 4 Sets the Time the unit plays 5 Turns Random Mode On or Off array. These switches control the length of time the unit will delay between recorded sounds. Please note that the unit will play for approximately 48 seconds each time it cycles on (the selected recordings will play either sequentially or non-sequentially, depending on the Random Mode setting) then it will go into a delay. The time the unit stays off depends on the Time Off and the Random Mode settings. If the unit is operating in Random Mode, the unit will delay anywhere from the minimum value to the maximum value for that Time Off setting (see below). If the unit is not in Random Mode, it will delay only the minimum value. To set the Time Off interval (or delay interval), use the following settings on switches 1 and 2 in the mode function settin

Open the catalog to page 1
Bird Gard SUPER PRO PA4 - 2

Time Off Period Short Medium Long Extra Long Mode Short Medium Long XLong Mode Day Only Night Only 24-Hour Operation IF YOU ARE NOT COMPLETELY SATISFIED, CONTACT THE PLACE OF PURCHASE OR OUR CUSTOMER SERVICE DEPARTMENT WITHIN ONE (1) YEAR OF YOUR DATE OF PURCHASE FOR PROMPT AND COURTEOUS REPLACEMENT, REPAIR OR REFUND. BIRD GARD, LLC’S LIABILITY HEREUNDER SHALL BE LIMITED TO REFUNDING THE PURCHASE PRICE PAID BY CUSTOMER OR REPLACING THE PRODUCT, IN BIRD GARD’S SOLE DISCRETION, AND UNDER NO CIRCUMSTANCES SHALL BIRD GARD BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES, OF ANY NATURE...

Open the catalog to page 2

All Bird Gard LLC catalogs and technical brochures