Catalog excerpts
Instructions manual for the automatic humidifier SIRIO 1 – Warnings for safe utilisation When using electrical appliances it is always required to adhere to some basic safety precautions, including the following: 1. 2. 3. 4. READ THE INSTRUCTIONS IN THEIR ENTIRETY. Use the appliance only with electrical system features complying with the label affixed on the appliance and with this manual. Do not place the unit close to heat sources and do not cover it with other objects. Do not leave the appliance unattended for long periods of time when it is connected to the power mains. Do not use the appliance with damaged cables or plugs, or appliances that have been dropped to the ground or damaged in some way. Consign the appliance to the nearest authorised service centre requesting its inspection, or repair. Use of accessories not recommended or not sold by the manufacturer is forbidden. Do not use outdoors. The appliance can be used by children under 12 years of age and/or persons with reduced physical or mental capacity, or without experience or the necessary knowledge, as long as supervised by an adult or after they have received instructions related to safe appliance use and understand the dangers related to it. The same is true for cleaning and maintenance. Always start use by verifying the feeder conditions, therefore connect it to the power outlet. To remove it, detach it from the power outlet. Disconnect the feeder from the power outlet when the appliance is not running. The feeder must be placed so it is easy to access when it is necessary to disconnect it from the power mains. To disconnect the feeder, grab it directly (not the cable) and detach it from the wall outlet. Any modification to this product that has not been expressly authorised by the manufacturer, besides representing a safety risk, will void the warranty. STORE THESE INSTRUCTIONS WITH CARE. Translation of original instructions Page 1 of 12 Rev 03
Open the catalog to page 1Electronic format copy of this instructions manual can be downloaded from the site www.borotto.com or can be requested by writing to the e-mail address info@borotto.com, specifying the product and the manual revision.
Open the catalog to page 2EU Declaration of conformity The undersigned Andrea Borotto, as legal representative of the company BOROTTO® with headquarters in Via Papa Giovanni Paolo II, 7 37060 Buttapietra (VR) Italy VAT No. 03787910235 DECLARES That the product as per the label shown below: Is intended for use as an accessory for maintaining humidity in incubators for animal eggs, specifically: hen, pheasant, turkey, guinea fowl, quail, grey partridge, partridge, goose, muscovy/common/wild duck, peacock, rock partridge, pigeon, Virginia quail, exotic birds and birds of prey. The following declaration of conformity is...
Open the catalog to page 3Attention, prior to performing any operation, carefully read the instructions manual. Warning symbols used on the product and in this manual Symbol Description Obligation to read the operating instructions before using the product DC Direct Current power supply Positive polarity at the centre of the power supply connector 3 - Identification plate The equipment is fitted with an identification plate showing the equipment's identification details and the main technical specifications. BOROTTO Via Papa Giovanni Paolo II, 7A 37060 Buttapietra (VR) Italy SIRIO automatic humidifier Year: XXXX...
Open the catalog to page 44 – Presentation of the manual This manual contains instructions for the installation, maintenance and use of the SIRIO peristaltic pump, here below simply called SIRIO. This manual is intended for users of the equipment, and concerns its use after its production and sale. In the event the equipment should be subsequently transferred to third parties for any reason (sale, loan for use, or any other reason), the equipment must be delivered complete with all its documentation. This manual contains proprietary information and may not be, even partially, provided to third parties for any...
Open the catalog to page 56 - SIRIO preparation and commissioning During transportation pay attention not to cause collisions and/or damage to the equipment. Always position flat, avoiding crushing and/or breakage. Demonstrative photo equivalent for all BOROTTO incubator models of the REAL series Position SIRIO on a flat surface. Do not place other objects between the product and the plane, for example tablecloths or covers. Position SIRIO next to the incubator, placing a water container nearby. Any container can be used: bottle, canister, etc., as long as it is clean inside. Dirty containers may result in the...
Open the catalog to page 6Insert the 2 valves with the pipes already connected to the incubator nozzles, making sure that they sufficiently penetrate the bottom in order to ensure hermetic seal. Attention to their insertion direction, it should follow the shape of the nozzle. ATTENTION: if the filling nozzles become encrusted with limestone, remove it with anti-scaling agent before inserting the valves. Insert the humidity sensor inside the incubator, positioning it above the flap in the corner (use a minimum amount of pressure to ensure blocking). The sensor cable must remain resting on the flat side on the edge of...
Open the catalog to page 7Position the humidity sensor on the opposite side of the incubator, compared to the filling nozzles. DO NOT PLACE THE SENSOR ABOVE THE WATER INLET TANKS!
Open the catalog to page 8REAL 49 7– Using SIRIO during incubation Turn on the incubator and make it run dry without water and without eggs for at least a few hours. After two hours of no-load operation, insert the eggs and make it run for at least another 2-3 hours. After the 2-3 hours of incubator operation with the eggs inserted, turn on Sirio by inserting the power supply jack in its front socket. Next insert the feeder plug into a power outlet. The display will show the desired humidity value detected, the symbol “H” means “humidity”. To set the desired humidity value, act on the buttons (+) and (-) located on...
Open the catalog to page 9ATTENTION: Do not incubate with the environment temperature below 20°C. Below this value, the temperature of the plastic bottom of the incubator (cold) does not allow the water to evaporate. SIRIO then continues to pump water into the incubator, unnecessarily flooding it. Thus, if during the incubation the water level were detected as higher than that of the eggcup, immediately disconnect the SIRIO feeder, in order to avoid flooding the eggs! 8 – Using SIRIO during hatching Once the incubation phase is completed, to move on to the hatching phase: • • disconnect SIRIO from the feeder. next,...