video corpo

ExhaustFans
1 /13Pages

ExhaustFans

ExhaustFans
1 /13Pages

Catalog excerpts

ExhaustFans-1

MOTOR PUTTING INNOVATION TO WORK Our ECsmart Motor is an EC motor. EC motors are electric motors that have permanent magnets on the rotor and use electronics to control the voltage and current applied to the motor. Canarm and Intelia - our Electronic control partner - have worked together to bring you our latest innovation - the ECsmart motor featuring patent pending electronics. The result is an ENERGY EFFICIENT motor that runs COOLER than any other in the industry. FEATURES • The First EC motor that can be varied with existing triac outputs or 0-1 Ov signal • Provides feedback for ventilation management • Can be retrofitted in any existing fan • Can be controlled by existing controls. • Testing has confirmed power savings of 25-75% • ECsmart motors run cooler, virtually eliminating winding failures and increasing lifespan on the motor • Tested at BESS labs in our PLF and FG series fans WARRANTY Comes with a FULL 5 YEAR warranty PLF & FG models now available with EC motors 1 $100 SAVE UP TO WITH THIS MOTOR Costs shown in Canadian dollars Subject to Change without notice.

 Open the catalog to page 1
ExhaustFans-2

MOTOR PLF-EC SERIES • Roto-molded impact resistant black polyethylene housings with UV prohibitors. • Platform mount • Easy to remove shutter assembly, complete with aerodynamic tie-bar poly louvers with stainless steel shutter frame and louver pin. • Corrosion proof airfoil polypropylene blades on 12" to 24" sizes. • Warranty: 5 years on plastic housing • Also available with our standard motor. For complete product infomation, please see PLF Fans In Exhaust Fan section FG-EC SERIES • The patented design provides excellent performance without a cone. • Chop & Spray design with smooth inside for...

 Open the catalog to page 2
ExhaustFans-3

PUTTING INNOVATION TO WORK PLASTIC WALL EXHAUST FANS GOOD PERFORMANCE • DEPENDABLE • GREAT VALUEIdeally suited for swine and poultry buildings. EASILY REMOVABLE SHUTTERS Flip latch open to release shutter FEATURES • 12" to 36" Sizes • Molded impact resistant black polyethylene housings with UV prohibitors. • Standard base mount motors are easily replaced. • Easy to remove shutter with welded steel frame and aerodynamic PVC louvers are held in place by a stainless spring steel pin and is virtually indestructible. • Powder coated exhaust guard. • Corrosion proof airfoil polypropylene blades on...

 Open the catalog to page 3
ExhaustFans-4

PUTTING INNOVATION TO WORK PLASTIC WALL EXHAUST FANS SPECIFICATIONS Specifications Shutter Frame Test Code Rough Opening Required cfm cfm/w cfm cfm/w amps cfm cfm/w Notes: AFR is the airflow ratio. Higher AFR indicates better performance under static pressure and against wind. It is calculated by dividing fan cfm at 0.20 static pressure by cfm at 0.05 sp. Test results are complete with cone where indicated. All tests completed with shutters installed. /^certified Amps indicated are actual at 230 volts. When determining amp load for variable speed, add 20% to listed numbers. Amp loads for 115...

 Open the catalog to page 4
ExhaustFans-5

FIBERGLASS FANS WCANARM AgSystems™ PUTTING INNOVATION TO WORK HIGH PERFORMANCE • LOW COST MAINTENANCE • LOW COST INSTALLATION Ideally suited for poultry, swine, dairy and greenhouse applications. FEATURES • The patented design provides excellent performance without a cone. • All fans are supplied completely assembled and are tested before shipping. • Chop & Spray design with smooth inside for improved cleaning. • Self draining, sloped housing is quick and easy to clean reducing maintenance costs. • T-Mount belt drive system provides quick, easy access to motor & blade. • Belt drive units are...

 Open the catalog to page 5
ExhaustFans-6

FIBERGLASS FANS PUTTING INNOVATION TO WORK SPECIFICATIONS Model Number Specify * bulk pak or single type speed Test Code single single No cone test available. 17.2 No cone test available. low single single single test code & test report code BELT DRIVE blade mat'l Model Codes: 3 =three phase, A=aluminum blade, B=Blue Ribbon, H=high output, BD=36"belt drive, BD4=3/4"hp 36" belt, V=variable speed, C=corrosion resistant Test Codes: B =BESS Labs report, C=Canarm Lab report-AMCA Fig. 15 test chamber Notes: AFR is the airflow ratio. Higher AFR indicates better performance under static pressure or against...

 Open the catalog to page 6
ExhaustFans-7

STANDARD FANS PUTTING INNOVATION TO WORK EFFICIENT • LOW MAINTENANCE • EASY INSTALLATIONCanarm’s standard fans follow a tradition of quality in design, materials and construction. All our standard fans are developed to be efficient and economically priced. All variable speed standard fans use an energy efficient variable speed, dual voltage motor and blade combination FEATURES • Available in 8" to 48" sizes. • Single, two and variable speed models are available. • All fans use a totally enclosed, thermally protected motor. • The rugged steel welded box housing has a durable powder coated finish....

 Open the catalog to page 7
ExhaustFans-8

STANDARD FANS ^CANARMAgSystems™ PUTTING INNOVATION TO WORK D|MENS|ONS t”’ seriS| Modei&Labe| against the fan. A 20 mph wind creates 0.20” pressure and 30 mph a blocks or hoods should be included in all designs where fans will be NOTE: RPM Min (Minimum) is determined when louvres are opened one inch. Note: Wind has a significant effect on exhaust fans. A 10 mph wind creates a 0.05” pressure 0.45” pressure. These pressures are in addition to the static pressure in the building. Wind subjected to winds above 10 mph. Some models are available with explosion proof motors. Please see next page. CANARM...

 Open the catalog to page 8
ExhaustFans-9

PUTTING INNOVATION TO WORK EXPLOSION PROOF STANDARD WALL EXHAUST FANS EFFICIENT • LOW MAINTENANCE • EASY INSTALLATION Efficient, low maintenance and easy to install. Canarm LFI’s explosion proof fans follow a tradition of quality in design, materials and construction. Using our quality “Standard Fan" housing and motor mount as the basis for design, we have developed an efficient, economically priced Explosion Proof Fan. All Explosion Proof Fans have j a single speed, dual voltage explosion proof motor that meets and conforms to all the _ standards that are listed below. CLASS I, GROUP C CLASS...

 Open the catalog to page 9

All Canarm AgSystems catalogs and technical brochures

  1. PENNING

    26  Pages

  2. LIFT CRATE

    2  Pages

  3. WATERER OPTIONS

    15  Pages

  4. NANO

    2  Pages

  5. BIRD SCALE

    1  Page

  6. GATES

    41  Pages

  7. TIE STALLS

    10  Pages

  8. iFeed

    1  Page

  9. Flooring

    25  Pages

  10. Tiestalls

    10  Pages

  11. Freestalls

    34  Pages

  12. PBKD Series

    1  Page

  13. HPWP Series

    3  Pages

  14. HAF Series

    1  Page

  15. CCU Series

    1  Page

  16. CA-AG Series

    2  Pages

  17. CA Series

    1  Page

  18. Panel Fan

    1  Page

  19. LF Series

    1  Page

  20. MTC-4C

    1  Page

  21. Heat Lamps

    3  Pages

  22. Hog Drinkers

    5  Pages

  23. Waterers

    15  Pages

  24. CCS Promo

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.