Note: The consumables are for single use only.
100 pcs test tubes with lyophilized dye 200 pcs pipette tips for automatic pipette (The consumables are for single use only ) Sample container Automatic pipette Pipette tip for automatic pipette Vortex mixer Test tube with lyophilized dye The accuracy of the measurement depends on the proper preparation of the sample and thorough mixing. It is mandatory to use raw milk, which can be either freshly milked or raw preserved at room temperature (15-25°C) – minimum 30 mL. The analysis should be performed within 4-5 hours after milking if the samples are not preserved. Freshly milked milk does not need to be tempered. Preserved and refrigerated milk samples are suitable f
Open the catalog to page 1SomaticScan To preserve raw milk samples, potassium dichromate (K2Q2O7) or bronopol (C3H6BrNO4) should be used in the quantities specified in the standard sampling procedures for analysis. The samples can then be stored in a refrigerator at 4°C. Before measurement, milk samples should be heated to 40°C and then cooled to 20°C. After that, they must be thoroughly mixed using a Vortex mixer to prevent measurement variations. The milk sample should not fill the container to the lid (no more than 50 mL) to allow easier mixing with the Vortex mixer. Raw or preserved milk with acidity above the following...
Open the catalog to page 2Pipetting raw milk into a test tube with lyophilized dye : • Take a test tube with lyophilized dye, open it, and place it on the stand. • Ensure the pipette tip is clean and uncontaminated. • Hold the pipette vertically above a tip from the pre-arranged ones on the stand. • Gently press the pipette cone into the tip opening to secure it. • Hold the pipette over the open test tube with lyophilized dye. • Press the button smoothly to the first stop to dispense the milk. • After a brief pause, press the button to the second stop to fully empty the tip. • Ensure the milk is dispensed without touching...
Open the catalog to page 3Mixing the sample: • After adding the milk sample to the test tube with lyophilized dye, securely close the tube. • Mix Using a Vortex Mixer • Press and hold the tube's tip against the Vortex mixer for 1-2 seconds, then release. • Repeat 8-9 times, ensuring the solution does not reach the tube cap The milk sample needs 1 minute to interact with the dye. If the interaction time is less than 1 minute or more than 20 minutes, the analysis result may vary by 2-3%.If more than 5 minutes have passed after adding milk to the test tube before filling the Somatic Chip, the sample must be mixed again....
Open the catalog to page 4SomaticScan • Use a pre-set automatic pipette set to 10 pL. • Ensure the pipette tip is clean and uncontaminated. • Hold the pipette vertically over a new pipette tip from the stand and gently press to secure it. • Open the test tube. • Use the automatic pipette to draw exactly 10 pL of the sample. • Ensure the pipette tip is properly filled without air bubbles. Hold the pipette at an approximately 80° angle relative to the semi-circular loading port on the letter-marked side of the microfluidic chambers. Gently press the pipette button from the initial position to the first stop. Hold the button...