video corpo

SolidFlow 2.0
4Pages

{{requestButtons}}

Catalog excerpts

SolidFlow 2.0 - 1

Solid Volume Measurement PROCESS MONITORING SYSTEMS FOR SOLIDS Product Information active roping compensation for highest reliability can be used in free fall and in pneumatics simple retrofitting using a welding socket no installations in the material stream almost all types of dust, powder and granules can be measured Throughput measuring up to 20 t/h ATEX-certified certificated according to www.envea.global

Open the catalog to page 1
SolidFlow 2.0 - 2

TECHNOLOGY USE SolidFlow 2.0 has been specially developed for measuring solid volumes conveyed through pipelines. SolidFlow 2.0 is used for online measuring: • all types of dust, powder, granulates, etc. • with particle sizes between 1 µm and 10 mm • which are conveyed pneumatically • or in free fall after mechanical conveyor systems SolidFlow  2.0 is extremely easy to install and has a wear-resistant design. SolidFlow  2.0 is the latest generation of microwavebased measuring systems for measuring the flow of solids. Based on our many years of expertise, ENVEA Process has developed a second...

Open the catalog to page 2
SolidFlow 2.0 - 3

TECHNOLOGY SYSTEM A complete measuring point consists of the following components: Evaluation unit • Evaluation Unit in DIN Rail- or Field housing • Sensor mount for welding to the pipe • Sensor (union nut, spacer rings, sealing ring for adjusting to the wall thickness) • Installation instructions • Teflon sleeve (depend on application) • C1- or C3-Box (optional) Evaluation unit DIN Rail APPLICATION EXAMPLES • Pneumatik At a boiler, dusts is conveyed as fuel into the combustion chamber. Each supply line is monitored by a SolidFlow 2.0 and the supply of fuel in each supply line is...

Open the catalog to page 3
SolidFlow 2.0 - 4

SPECIFICATIONS TECHNICAL DATA Sensor Stainless steel 1.4571 Protection type IP65, DustEx zone 20 or GasEx zone 1 (optional) Operating temperature Front end of sensor: -20 … + 80 °C Optional: -20 … +220 °C Sensor electronic: 0 … + 60 °C Working frequency Transmitting power Transmitter (field housing) Power supply Power supply Power consumption Power consumption Protection type Protection type Ambient operating temperature Ambient operating temperature Connection terminals cable cross-section Cable screw connectors Current output Connection terminals cable cross-section Current output Pulse...

Open the catalog to page 4

All ENVEA catalogs and technical brochures

  1. MaxxFlow HTC

    4 Pages

  2. M-SENS WR2

    4 Pages