F-940

F-940

F-940

Product catalog summary
Overview: The F-940 Store It! Gas Analyzer is designed to assist Quality Assurance managers in extending shelf-life and preventing spoilage by monitoring ripening gases during storage. It measures ethylene (C2H4), carbon dioxide (CO2), and oxygen (O2) levels, providing results in under 30 seconds. The device is handheld, lightweight, and features a battery life of over 8 hours, with a display that is easily readable in dim lighting. It includes a PolarCept!TM water filter to remove non-ethylene hydrocarbons and offers Wi-Fi connectivity.
Product Features:
  • Controlled Atmosphere storage management
  • Ethylene mitigation verification
  • Packing house inspection
  • Precision citrus degreening
  • Storage assignment in distribution centers
  • Modified Atmosphere Packaging quality assurance
Specifications:
  • Sampling flow rate: 70mL/min
  • Operating environment: 0°C - 50°C
  • Total Sampling Time: 30 seconds
  • Weight: 0.95 kg
  • Data saving: Automated (1 sec)
  • Enclosure: Powder coated aluminum
  • Display: Sunlight Visible LCD
  • Power source: Removable battery (Li-ION)
  • Dimensions: 18 cm x 13.5 cm x 5.5 cm
  • PC interface: USB, WIFI, SD card, Bluetooth
  • Battery Life: 8.5 hours
  • Operating Pressure: 500-1200mbar
Sensor Details:
  • Headspace Sampling:
    • Ethylene (C2H4): Electrochemical sensor, range 0-10 ppm, resolution 0.01 ppm, lower detection limit 0.15 ppm, response time 30 seconds, accuracy 0.15 ppm absolute, 5% relative, offset calibration weekly, span calibration every 3 months, user-replaceable sensor, lifetime 2 years.
    • CO2: Infrared Sensor, Pyroelectric detector, range 0-100%, resolution 0.01%, lower detection limit 0.50%, response time 12 seconds, accuracy 0.50% absolute, 3% relative, offset calibration weekly, span calibration every 12 months, lifetime > 5 years.
    • O2: Electrochemical sensor, range 0-100%, resolution 0.10%, lower detection limit 0.30%, response time 12 seconds, accuracy 0.30% absolute, 2% relative, offset calibration weekly, span calibration every 6 months, user-replaceable sensor, lifetime 2 years.
  • Continuous Sampling:
    • Ethylene (C2H4): Electrochemical sensor, range 0-10 ppm, resolution 0.010 ppm, lower detection limit 0.030 ppm, response time 70 seconds, accuracy 0.030 ppm absolute, 5% relative, offset calibration weekly, span calibration every 3 months, user-replaceable sensor, lifetime 2 years.
    • CO2: Infrared Sensor, Pyroelectric detector, range 0-100%, resolution 0.01%, lower detection limit 0.01%, response time 6 seconds, accuracy 0.01% absolute, 3% relative, offset calibration weekly, span calibration every 12 months, lifetime 5 years.
    • O2: Electrochemical sensor, range 0-100%, resolution 0.10%, lower detection limit 0.10%, response time 12 seconds, accuracy 0.10% absolute, 2% relative, offset calibration weekly, span calibration every 6 months, user-replaceable sensor, lifetime 2 years.
Data Recorded: Ethylene, CO2, O2 concentrations, date, time, RH, GPS location.
See more

Catalog excerpts

F-940-1

The F-940 Store It! Gas Analyzer makes it easy for Quality Assurance managers to increase shelf-life and prevent spoilage by monitoring ripening gases throughout the storage process. Product Features ► Measures C2H4, CO2 and O2 ► Displays results in under 30 seconds ► Past records stored on the device ► Handheld and lightweight ► Battery lasts for 8+ hours ► Display easily viewed in dimly lit environments ► PolarCept!™ water filter for removing non-ethylene hydrocarbons ► Wi-Fi capabilities ► Controlled Atmosphere storage facility management ► Ethylene mitigation verification ► Packing house inspection ► Precision citrus degreening ► Storage assignment in distribution centers ► Modified Atmosphere Packaging quality assu

 Open the catalog to page 1
F-940-2

Sensor Type: Electrochemical Lower Detection Limit: 0.15 ppm Offset Calibration: Weekly User Replaceable Sensor: yes_ Weekly Weekly Sampling flow rate Headspace Sampling Continuous Sampling Sensor Type: Electrochemical Lower Detection Limit: 0.030 ppm Offset Calibration:_Weekly_ User Replaceable Sensor: yes_ www.felixinstruments.com [email protected] Phone: +1 (360) 833-8835 Toll Free: 1-800-767-0119 Fax: +1 (360) 833-1914 Made in USA