DO THE GALLAGHER CHECK
2Pages

{{requestButtons}}

Catalog excerpts

DO THE GALLAGHER CHECK - 1

CHECK YOUR FENCE: DO THE GALLAGHER CHECK! ELECTRIC FENCING WWW.GALLAGHER.EU / CHECK ✓ Tick the steps when you have completed them. CHECK YOUR ENERGIZER : 1. Turn your energizer off 2. Disconnect the fence from the red button 3. Turn the energizer on Go back to your energizer and check your earthing (step Is the difference to the Voltage of the energizer less than 1500V? (E.g. energizer was 6000V and the fence is 5500V? That is less than 1500V) Y our energizer and your earthing are both ok. Please go to step 9. 4. Measure the Voltage on the energizer with a digital volt meter or a Fault finder. Place this on the red button of the energizer. Put the contact pin / contact plate of the Faultfinder/ DVM on the red button (fence) and the little earth pin of the Faultfinder/ DVM on the green button (earthing). Is the voltage lower than 6000V? 9 I n this case your energizer is broken. Please contact the Gallagher specialist and see if your energizer can be repaired. Is the voltage higher or equal to a voltage of 6000V? 9 I n this case your energizer is ok. Please note the voltage CHECK YOUR FENCE: 9. ake an inventory of your complete fence by passing it M and check if your fencing material is still intact. Are your conductors tight on all places? Yes, continue with the next step. No: please tighten them o For Cord use a rotating tensioner – Part. No. 010882 or wire tensioners handle Part. No. 029044 you have measured and go to step 5. 5. Turn the energizer off again. 6. onnect the fence again to the red button. C 7. Turn the energizer on again. CHECK THE VOLTAGE ON YOUR FENCE: 8. o to the end of your fence and check the Voltage here G with a DVM or a Fault Finder. I s the difference to the Voltage of the energizer more than 1500V? (E.g. energizer was 6000V and the fence is 4000V? That is more than 1500V) Discover your best fence at www.gallagher.eu/

Open the catalog to page 1
DO THE GALLAGHER CHECK - 2

ELECTRIC FENCING Are the conductors still intact? A re the gates still intact? (The gate handles undamaged, conductors tightened)? Yes, continue with the next step. N o: please add a conductor o idoflex Connector: Part. No. 060764 V o igh tensile: just put this together with a connection H Yes: continue with next step No: Please replace the broken or worn out parts. You have completed the Gallagher check! If your fence has the correct voltage and you have replaced all the damaged materials, we wish you a great new season! Yes, continue with the next step. CHECK YOUR EARTHING : 10. Checking...

Open the catalog to page 2

All Gallagher Europe catalogs and technical brochures

  1. W-1

    108 Pages

  2. TWR-1

    120 Pages

  3. TW-3

    112 Pages

  4. TWR-5

    120 Pages

  5. W-0

    88 Pages

  6. Catalogue 2016

    92 Pages