video corpo

TWR-1

TWR-1
1 / 120 PagesView full catalog

TWR-1

Product catalog summary
Box Contents
The Gallagher TWR-1 Weigh Scale package includes a carry bag, weighing unit, AC adapter, USB cable, USB flash drive, battery cable with alligator clips, mini serial adapter, and mounting bracket with hardware.
Specifications
The TWR-1 operates within a temperature range of -20°C to 50°C and has an IP67 environmental protection rating. It requires a 12V DC input voltage. Battery life varies based on brightness settings, with a maximum of 16 hours for weighing only at 60% brightness.
Charging the Battery
Charge the battery for up to 16 hours before first use. Store the unit in a cool, dry place at 50% capacity for optimal battery life. The power adapter is for indoor use only.
Understanding the TWR-1 Weighing Unit
The unit features a touch screen, weigh button, zero button, home button, power button, and navigation keys. It includes indicators for WiFi, Bluetooth, battery charge, and weighing mode.
Installation
The TWR-1 can be placed on a tabletop or mounted using the supplied bracket. Loadbars should be installed on a solid, level surface and connected to the TWR-1. Avoid welding near loadbars to prevent damage.
First Time Start-Up
Upon first powering on, update language, time, date, and weight settings. The unit will auto-shutdown after 30 minutes of inactivity unless connected to a charger.
Connecting Equipment
Connect to wireless loadbars via settings. EID readers can be connected through Bluetooth, serial cable, USB, or internal reader. Drafter connections require specific data cables.
Start a Session
Sessions record animal data. Use templates for new sessions. Ensure the scale reads 0.0 before weighing. The internal reader scans EID tags when loadbars detect weight.
View Animal Information
Session data can be viewed on the Weigh screen. Access information for all animals or individual animal history.
Wi-Fi Connection and Software Updates
The TWR-1 device can connect to Wi-Fi to receive software updates. Navigate to Settings > Device Settings > Wi-Fi, enable Wi-Fi, search for available networks, select your network, and enter the password. The device will automatically check for updates when connected to Wi-Fi.
Care and Maintenance
The TWR-1 is designed for livestock environments and requires proper care to extend its lifespan. It should not be submerged in liquid, should be stored in a cool, dry place away from direct sunlight, and cleaned with a damp cloth without scratching the display.
Data Transfer
Users can download the Gallagher Animal Performance app to sync data from the TWR-1. Ensure Wi-Fi is connected, press the Synchronise icon, and follow prompts to enter registration credentials if syncing for the first time.
Approvals and Standards
The TWR-1 complies with FCC and Industry Canada regulations, ensuring it does not cause harmful interference and accepts interference from other devices. It must be disposed of at designated recycling points to protect the environment.
Installation and Setup
The TWR-1 can be mounted on a table or using the provided bracket. It should not be mounted on weighing crates to avoid performance issues. The device includes a touch screen, weighing button, reset button, and power button for operation.
Device Connections
Connect to wireless load bars via the settings menu. The TWR-1 can also connect to IDE readers and sorters using Bluetooth, serial cables, or USB.
Session Management
Data collected during weighing is stored in sessions. Start a new session for new activities or groups of animals. The device supports automatic and manual weight locking modes.
Maintenance and Disposal
The TWR-1 is designed for livestock use and requires proper maintenance to extend its lifespan. It should not be submerged in liquids and should be stored in a cool, dry place. The document also includes disposal instructions, emphasizing recycling to protect the environment.
Compliance
The device complies with FCC regulations and is designed to minimize interference with other electronic devices. Users are advised on steps to take if interference occurs.
See more

Catalog excerpts

TWR-1-1

QUICK START GUIDE TWR-1 English Gallagher TWR- Weigh Scale Quick Start Guide Thank you for purchasing the Gallagher TWR- Weigh Scale unit. The Gallagher range of weighing systems is simple, tough, innova ve and reliable. BONUS OFFER Register your product online at www.gallagherams.com to extend your warranty to two years for free. Follow these instruc ons for the setup and first use of the TWR- . Further informa on can be obtained by tapping when displayed on screen. BOX CONTENTS The Gallagher TWR- box contains: • Carry Bag • TWR- weighing unit • 110V - 230V Mains AC adapter • USB cable • USB flash drive • 12V ba ery cable with alligator clips • Mini Serial Adapter (2M1709) • Moun ng bracket and

 Open the catalog to page 1
TWR-1-2

Gallagher TWR- Weigh Scale Quick Start Guide SPECIFICATIONS Opera ng Temperature Environmental Protec on Ra ng Input Voltage Es mated ba ery run me 12 hours 6 hours 3 hours 16 hours 8 hours 4 hours Weigh only Weigh/Read Read only CHARGING THE BATTERY To ensure op mum performance of the TWR- , the internal ba ery may need to be charged for up to 16 hours before first me use. Important: If the TWR- is to be stored for an extended period, this should be in a cool dry place. For op mum ba ery life, store the TWR-1 at 50% capacity. Always charge the ba ery indoors. 1. Connect the power adapter at the...

 Open the catalog to page 2
TWR-1-3

Gallagher TWR-1 Weigh Scale Quick Start Guide Find animal Look up and add animal to a session Remove animal On-screen Help Touch to display informafion about the current screen Touch Screen- Tap the screen icons, field names or buttons to view or enter data. Weigh button Records animal weight Zero button Sets the displayed - weight to zero Navigation keys— These buttons can be used to navigate the funcfions of the scale as an alternafive to the touch screen. Weigh screen Footer bar Power button Turn TWR-1 On/Off Home Button Return to the Home screen Change mode from numeric Backspace/Delete to...

 Open the catalog to page 3
TWR-1-4

Gallagher TWR- Weigh Scale Quick Start Guide INSTALLATION English Installing the TWRThe TWR- can be placed on a table top or mounted on the bracket supplied. Installing the Scale bracket The bracket can be mounted on a flat ver cal surface, a round post, or a rail. To mount the bracket on a flat ver cal surface, or a round wooden post, use the 4 x tek screws included with the unit. To mount the bracket on either a ver cal or horizontal bar, use the ‘U’ bolts included with the unit. Important: It is not recommended to mount the TWR- bracket on the weighing crate or chute as interac on with the scale...

 Open the catalog to page 4
TWR-1-5

Gallagher TWR-1 Weigh Scale Quick Start Guide Gallagher TWR-1 Weigh Scale Quick Start Guide Installing the loadbars If using loadbars, follow these steps: 1. Select a weighing site that provides a solid, level and well drained surface. 2. Ensure the loadbars and platform are well secured and clear of any obstructions. 3. Either bolt the loadbars to the concrete pad or locate them on studs set into the concrete. It is important that the loadbars and platform sit flat without any rocking or twisting to avoid weighing inaccuracies. Note: It may be necessary to shim the loadbars or platform to ensure...

 Open the catalog to page 5
TWR-1-6

Gallagher TWR- Weigh Scale Quick Start Guide Installing the Antenna Panel The TWR-1 has an internal reader, that when connected to a Gallagher Antenna panel will capture the Electronic ID tag data. To weigh animals in a crush, you will need: • Gallagher Antenna Panel kit • 4m Antenna Extension Cable G05600 or 6m Antenna Extension Cable G05602 Note: A short adapter cable G05601 may be required on early versions of the Sheep Auto Dra er made prior to 2018. To mount your Antenna panel, refer to the instruc ons included with the panel. Important: Use the defined moun ng holes, because drilling through...

 Open the catalog to page 6
TWR-1-7

Gallagher TWR- Weigh Scale Quick Start Guide FIRST TIME START-UP To change any of these se ngs later, they can be accessed via Se ngs right of the Home screen. The first me the TWR- is powered on, the First Time Start-Up screen will display. Tap the screen to update the language, me, date and weight fields as required and then tap Save. displayed in For more informa on about this screen or any TWR- screen, tap the top right corner of the screen. This will display the On-screen Help with more informa on about what you see on the screen. Note: The naviga on keys on the keypad can be used at any me...

 Open the catalog to page 7
TWR-1-8

Gallagher TWR- Weigh Scale Quick Start Guide CONNECTING EQUIPMENT TO THE TWR-1 Connecting to Wireless Loadbars English On the TWR-1, tap Se ngs > Equipment Connec ons > Loadbars > Wireless. The TWR-1 will search for the loadbars. When the loadbars have been located, tap to select them from the list, then tap Connect. Note: As per the Wireless Loadbar Installa on instruc ons, your loadbars must be switched on and in range to display in the search list. The connec on process will take up to 30 seconds while pairing occurs between the loadbars and the TWR-1. Once completed, tap Done. Create a new...

 Open the catalog to page 8
TWR-1-9

Gallagher TWR- Weigh Scale Quick Start Guide Refer to Bluetooth – Connect EID Reader in the TWR-1 On-screen Help or your EID Reader User Manual for further informa on on pairing the reader. Connecting to a Drafter/Sorter To connect the TWR- to a dra er, use the data cables supplied with your dra er. Refer to your Dra er User Manual for more informa on. 1. Turn On the TWR- . 2. 3. On the TWR- , tap Se ngs > Equipment Connec ons > Dra er. Specify the type of dra er that is being connected, to complete the setup. If your dra er is not listed, tap Create Custom and follow the configura on wizard set...

 Open the catalog to page 9
TWR-1-10

Gallagher TWR- Weigh Scale Quick Start Guide If using the internal reader, the animal’s Electronic ID will be scanned, or you can scan with a hand-held reader and record the animal’s Visual Tag Number. Note: The internal reader will only read a tag when loadbars are connected and weight is detected on the weighing pla orm. If weighing in AUTO - Automa c weight lock, the scale will lock on to the weight and hold it on the screen un l the animal leaves the pla orm. If weighing in MAN - Manual weight lock, you must first press Weigh When the weight becomes stable, it will lock. Important: If the...