Product catalog summary
Box Contents
The Gallagher TWR-5 Weigh Scale package includes essential components such as a carry bag, weighing unit, AC adapter, USB cable, flash drive, battery cable, mini serial adapter, and mounting bracket.
Specifications
The device operates within a temperature range of -20°C to 50°C and has an IP67 environmental protection rating. It requires a 12V DC input voltage. Battery life varies based on usage and brightness settings, with an estimated runtime of 12 to 16 hours for weighing only.
Battery Charging
Charge the battery for up to 16 hours before first use. Store the unit at 50% capacity in a cool, dry place for optimal battery life. The battery icon on the screen indicates charge status.
Device Features
The TWR-5 features a touchscreen, weigh button, zero button, home button, power button, and various connection ports. It supports both automatic and manual weight lock modes.
Installation
The TWR-5 can be placed on a tabletop or mounted using the provided bracket. Loadbars should be installed on a solid, level surface and connected to the TWR-5. Avoid welding near loadbars to prevent damage.
First Time Start-Up
Upon first powering on, set language, time, date, and weight units. The device will auto-shutdown after 30 minutes of inactivity unless connected to a charger.
Connecting Equipment
Wireless loadbars can be connected via the settings menu. EID readers can be connected using Bluetooth, serial cable, or USB. Ensure the antenna panel is properly attached for internal reader use.
Starting a Session
Sessions record animal data and can be customized with templates. New sessions should be started for each day's activity or new group of animals. Weighing can be done in automatic or manual modes.
View Animal Information
Session data can be viewed on the weigh screen, including individual animal information and weight ranges.
Care and Maintenance
Regular maintenance is recommended to ensure optimal performance. Follow the guidelines for cleaning and storing the device. Avoid submerging it in liquids and store it in a cool, dry place.
Approvals and Standards
The TWR-5 complies with relevant industry standards and approvals, including FCC and Industry Canada regulations. It must be disposed of at designated collection points for recycling.
Wi-Fi Connection and Software Updates
The TWR-5 can connect to Wi-Fi to synchronize data with the Gallagher Animal Performance app and receive software updates. Ensure Wi-Fi is enabled and follow the on-screen instructions for updates.
Data Transfer and Synchronization
Data from sessions can be synchronized with the Gallagher Animal Performance application. The process requires Wi-Fi connectivity and involves entering registration credentials for the first synchronization.
See more

Catalog excerpts

TWR-5-1

Gallagher TWR- Weigh Scale Quick Start Guide QUICK START GUIDE TWR-5 Thank you for purchasing the Gallagher TWR- Weigh Scale unit. The Gallagher range of weighing systems is simple, tough, innova ve and reliable. BONUS OFFER Register your product online at www.gallagherams.com to extend your warranty to two years for free. Follow these instruc ons for the setup and first use of the TWR- . Further informa on can be obtained by tapping when displayed on screen. BOX CONTENTS The Gallagher TWR- box contains: • Carry Bag • TWR- weighing unit • 110V - 230V Mains AC adapter • USB cable • USB flash drive • 12V ba ery cable with alligator clips • Mini Serial Adapter (2M1709) • Moun ng bracket and

 Open the catalog to page 1
TWR-5-2

Gallagher TWR- Weigh Scale Quick Start Guide Input Voltage Es mated ba ery run me Weigh only Weigh/Read Read only 12 hours 6 hours 3 hours at 60% brightness 16 hours 8 hours 4 hours CHARGING THE BATTERY To ensure op mum performance of the TWR- , the internal ba ery may need to be charged for up to 16 hours before first me use. Important: If the TWR- is to be stored for an extended period, this should be in a cool dry place. For op mum ba ery life, store the TWR-5 at 50% capacity. Always charge the ba ery indoors. 1. Connect the power adapter at the base of the unit and plug the TWR- into a power...

 Open the catalog to page 2
TWR-5-3

Gallagher TWR- Weigh Scale Quick Start Guide UNDERSTANDING THE TWR-5 WEIGHING UNIT Remove animal On-screen Help Touch to display informa on about the current screen Look up and add animal to a session Find animal Weigh screen Touch Screen Tap the screen icons, field names or bu ons to view or enter data. Weigh bu on Records animal weight Sets the displayed weight to zero. Return to the Home screen These bu ons can be used to navigate the func ons of the scale as an alterna ve to the touch screen. Backspace/Delete Space bar Qwerty keyboard Footer bar detail Ba ery charge indicator Bluetooth status...

 Open the catalog to page 3
TWR-5-4

Gallagher TWR- Weigh Scale Quick Start Guide INSTALLATION English Installing the TWRThe TWR- can be placed on a table top or mounted on the bracket supplied. Installing the Scale bracket The bracket can be mounted on a flat ver cal surface, a round post, or a rail. To mount the bracket on a flat ver cal surface, or a round wooden post, use the 4 x tek screws included with the unit. To mount the bracket on either a ver cal or horizontal bar, use the ‘U’ bolts included with the unit. Important: It is not recommended to mount the TWR- bracket on the weighing crate or chute as interac on with the scale...

 Open the catalog to page 4
TWR-5-5

Gallagher TWR- Weigh Scale Quick Start Guide If using loadbars, follow these steps: 1. Select a weighing site that provides a solid, level and well drained surface. 2. Ensure the loadbars and pla orm are well secured and clear of any obstruc ons. 3. Either bolt the loadbars to the concrete pad or locate them on studs set into the concrete. It is important that the loadbars and pla orm sit flat without any rocking or twis ng to avoid weighing inaccuracies. Note: It may be necessary to shim the loadbars or pla orm to ensure there are no twis ng pressures within the pla orm. Weights should be evenly...

 Open the catalog to page 5
TWR-5-6

Gallagher TWR- Weigh Scale Quick Start Guide Installing the Antenna Panel The TWR-5 has an internal reader, that when connected to a Gallagher Antenna panel will capture the Electronic ID tag data. To weigh animals in a crush, you will need: • Gallagher Antenna Panel kit • 4m Antenna Extension Cable G05600 or 6m Antenna Extension Cable G05602 Note: A short adapter cable G05601 may be required on early versions of the Sheep Auto Dra er made prior to 2018. To mount your Antenna panel, refer to the instruc ons included with the panel. Important: Use the defined moun ng holes, because drilling through...

 Open the catalog to page 6
TWR-5-7

Gallagher TWR- Weigh Scale Quick Start Guide FIRST TIME START-UP To change any of these se ngs later, they can be accessed via Se ngs right of the Home screen. The first me the TWR- is powered on, the First Time Start-Up screen will display. Tap the screen to update the language, me, date and weight fields as required and then tap Save. displayed in For more informa on about this screen or any TWR- screen, tap the top right corner of the screen. This will display the On-screen Help with more informa on about what you see on the screen. Note: The naviga on keys on the keypad can be used at any me...

 Open the catalog to page 7
TWR-5-8

Gallagher TWR- Weigh Scale Quick Start Guide CONNECTING EQUIPMENT TO THE TWR-5 Connecting to Wireless Loadbars English On the TWR-5, tap Se ngs > Equipment Connec ons > Loadbars > Wireless. The TWR-5 will search for the loadbars. When the loadbars have been located, tap to select them from the list, then tap Connect. Note: As per the Wireless Loadbar Installa on instruc ons, your loadbars must be switched on and in range to display in the search list. The connec on process will take up to 30 seconds while pairing occurs between the loadbars and the TWR-5. Once completed, tap Done. Create a new...

 Open the catalog to page 8
TWR-5-9

Gallagher TWR- Weigh Scale Quick Start Guide Refer to Bluetooth – Connect EID Reader in the TWR-5 On-screen Help or your EID Reader User Manual for further informa on on pairing the reader. Connecting to a Drafter/Sorter To connect the TWR- to a dra er, use the data cables supplied with your dra er. Refer to your Dra er User Manual for more informa on. 1. Turn On the TWR- . 2. 3. On the TWR- , tap Se ngs > Equipment Connec ons > Dra er. Specify the type of dra er that is being connected, to complete the setup. If your dra er is not listed, tap Create Custom and follow the configura on wizard set...

 Open the catalog to page 9
TWR-5-10

Gallagher TWR- Weigh Scale Quick Start Guide If using the internal reader, the animal’s Electronic ID will be scanned, or you can scan with a hand-held reader and record the animal’s Visual Tag Number. Note: The internal reader will only read a tag when loadbars are connected and weight is detected on the weighing pla orm. If weighing in AUTO - Automa c weight lock, the scale will lock on to the weight and hold it on the screen un l the animal leaves the pla orm. If weighing in MAN - Manual weight lock, you must first press Weigh When the weight becomes stable, it will lock. Important: If the...