1. Catalogs
  2. Gigola e Riccardi Spa
  3. HIGH PRESSURE EXHAUST FANS ENG_ITA
video corpo

HIGH PRESSURE EXHAUST FANS ENG_ITA

HIGH PRESSURE EXHAUST FANS ENG_ITA

HIGH PRESSURE EXHAUST FANS ENG_ITA

Product catalog summary
Main Features
The HP 140 R/S - 51” exhaust fans by Gigola e Riccardi S.p.A. are designed for high-pressure environments such as breeding farms, industries, and greenhouses. The fans feature new stainless steel blades that enhance energy efficiency and air capacity, even in high-pressure settings (0.12–0.24 in H2O or 30-60 Pa).

Patented Systems
The fans incorporate a patented centrifugal shutter opening system that operates without additional electrical devices. The X-shaped support structure, made from triangular profile tubes, provides robustness and reduces vibrations.

Venturi Nozzle and Customization
The moplen Venturi nozzle is corrosion-resistant, easy to install, maintain, and clean. It can be customized with the client's company color for orders of 500 or more units.

Additional Features
- Metal shaped shutter sides limit light and dust entry when the fan is inactive.
- Double bearings enhance balance and durability.
- AISI 304 stainless steel version is available for highly corrosive environments.
- The motor support arm allows quick motor disassembly without pulley removal.

Compliance and Safety
The fans are designed to withstand humidity, heat, and cold, suitable for corrosive or abrasive environments. Users must ensure compliance with local regulations, especially regarding motor specifications and safety grids.

Technical Specifications
- Power options: 1.5 hp (1.1 kW) and 1 hp (0.75 kW) with voltage of 230/400 V and frequency of 50/60 Hz.
- Dimensions: A - 1380 mm, B - 405 mm, C - 51 in, Weight - 68 kg.
- Performance tested according to UNI 7179-73P standards.
- Noise levels: 74.6 dB(A) for 1.5 hp and 71.8 dB(A) for 1 hp at 2 meters, compliant with ISO 3744.

Performance Data
The fans deliver varying airflows and efficiencies at different pressures, with detailed performance metrics provided for both metric (m3/h) and imperial (CFM) units.

Components and Spare Parts
An exploded drawing lists all fan components, with instructions for ordering spare parts by model and reference number.

Loading Options
The document provides loading options for assembled and unassembled fans, detailing quantities per container size and standard truck.

Contact Information
Gigola e Riccardi S.p.A. is headquartered in Cazzago San Martino, Italy, with contact details provided for both the fan production plant and the cooling pad system plant.
See more

Catalog excerpts

HIGH PRESSURE EXHAUST FANS ENG_ITA-1

EXHAUST FANS VENTILATORI ESTRATTORI PATENTED SHUTTER OPENING SYSTEM SISTEMA BREVETTATO PER L’APERTURA DELLA SERRANDA NEW BLADES NUOVE PALE HIGH PRESSURE SERIES SERIE ALTA PRESSIONE HP 14O R/S - 51” BREEDING FARMS / ALLEVAMENTI GREENHOUSES / SERRE INDUSTRIES / INDUSTRIE

 Open the catalog to page 1
HIGH PRESSURE EXHAUST FANS ENG_ITA-2

MAIN FEATURES PRINCIPALI CARATTERISTICHE NEW NEW EASY MOTOR UNASSEMBLY SISTEMA PER UN FACILE SMONTAGGIO DEL MOTORE Our new motor support arm allows the motor to be unassembled quickly without removing the pulley. Il nostro nuovo braccio porta motore permette lo smontaggio del motore in modo rapido, senza dover rimuovere la puleggia. STAINLESS STEEL BLADES Our new blades provide our fans with increased energy efficiency and air capacity even when they are installed in big tunnels or warehouses, where pressure is high (0,12–0,24 in H2O). PALE IN ACCIAIO INOX Le nostre nuove pale conferiscono al...

 Open the catalog to page 2
HIGH PRESSURE EXHAUST FANS ENG_ITA-3

NOISE LEVEL / RUMOROSITA Our fans have been tested in compliance with UNI 7179-73P rules. Technical information may be changed due to future improvements, without forewarning. I ventilatori sono stati provati a norma UNI 7179-73P. Le specifiche tecniche sono soggette a variazioni per miglioramenti, senza preavviso. Sound pressure level LpA at 2 mt in accordance with the execution rules mentioned in the ISO 3744 standard. * Il livello di pressione sonora LpA misurato a 2 mt con modalita di esecuzione in accordo lo standard ISO 3744.

 Open the catalog to page 3
HIGH PRESSURE EXHAUST FANS ENG_ITA-4

* Spedfy if the b|ade is o|d mode| or new m°de| * Specificare se pala vecchio modeNo oppure nuovo modeNo NOTICE: For spare parts orders, please provide the model of the fan (ex. HP 8O R/S or HP 1OO R/S etc.) and the reference number of the spare part.AVVISO: Per Vs. richieste di pezzi di ricambio pregasi comunicare il modello di ventilatore e (es. HP 8O R/S o HP 1OO R/S etc.) il numero di riferimento del pezzo.

 Open the catalog to page 4
HIGH PRESSURE EXHAUST FANS ENG_ITA-5

APPLICATION PLANS SCHEMI DI APPLICAZIONE VENTILAZIONE TRASVERSALE WITH HEAD CONVEYING AIR (up to 7O m) VENTILAZIONE LONGITUDINALE CON INGRESSO ARIA IN TESTATA (fino a 7O m) WITH HEAD CONVEYING AIR (over 7O m) VENTILAZIONE LONGITUDINALE CON INGRESSO ARIA IN TESTATA (oltre 7O m) LOADING OPTIONS / POSSIBILITÀ DI CARICO ASSEMBLED FANS / VENTILATORI MONTATI UNASSEMBLED FANS / VENTILATORI SMONTATI TYPE TIPO STANDARD TRUCK* TYPE TIPO STANDARD TRUCK* * STANDARD DIMENSIONS ARE SHOWN IN THE PICTURE * LE DIMENSIONI STANDARD SONO MOSTRATE IN FOTOGRAFIA GIGOLA E RICCARDI S.p.A. FANS VENTILATORI Headquarter...

 Open the catalog to page 5
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.