Catalog excerpts
Small Animal || Room TECHNICAL SPECIFICATIONS D. IT MUST NOT BE COPIED OR PERMITTED TO BE COPIED NOR MUST ITS CONTENTS BE RPOSES OF INFORMATION AND/OR QUOTATION SHALL IMPLY AN AGREEMENT This document outlines some of the high-level technical specifications and considerations in planning for the installation of the Hallmarq Small Animal MRI system. Please consult the Site Planning Guide for additional details. GOING CONDITIONS. THIS PRINT MUST BE RETURNED WHEN NO LONGER Standard room Total internal area 614 sqft (57 sqm) 29'-6" (9.0m) From centre of magnet Truck Exclusion Zone Car Exclusion Zone MRI ELECTRICAL REQUIREMENTS 24'-7" (7.5m) From centre of magnet Power type Power type 3 Phase + Protective Earth Main line transformer capacity Main line transformer capacity Minimum 100kVA Electrical Board System Cabinet Voltage Voltage Filter Panel Heat Exchanger Gradient Amplifier Quench pipe Amp service 126A (variable depending upon voltage) 20'-4" (6.2m) From centre of magnet 14'-9" (5.5m) From centre of magnet Helium Compressor 100A - 73A depending upon voltage Coil Rack Earth grounding Earth grounding The system requires grounding of 2 ohm or less The system requires grounding of 2 ohm or less 4'-0" 1219mm Maximum inbalance between lines 2% CONTROL ROOM Viewing window Chiller power requirements Minimum Bandwidth Power down. 500KB up andtype 3 Phase +PE Voltage 460V AC Final specifications subject to contract LOCATION DESCRIPTION Standard Layout General Specifications ©Hallmarq Veterinary Imaging 2020 | hallmarq.net Frequency SCALE 1:100 Sept 2019 60@A3 Hz DATE REVISIONS DESCRIPTION
Open the catalog to page 1Small Animal || Room TECHNICAL SPECIFICATIONS This document outlines some of the high-level technical specifications and considerations in planning for the installation of the Hallmarq Small Animal MRI system. Please consult the Site Planning Guide for additional details. 1.5T field strength 16 channels 60 cm patient bore diameter 35 mT/m gradient amplitude 130 T/m/s gradient slew rate On-board radio-frequency (RF) shield V-shaped patient bed Video patient monitoring with LED lighting Up to 40% more energy efficient compared to used MRIs Zero helium boil-off cold head • Air cooled helium...
Open the catalog to page 2All Hallmarq Veterinary Imaging catalogs and technical brochures
-
2018 STANDING EQUINE MRI
8 Pages
-
REFERRING FOR EQUINE MRI
2 Pages
-
Veterinary CT
3 Pages
-
SMALL ANIMAL MRI
5 Pages
-
Escala saher culivators
2 Pages
-
MIST BLOWERS
4 Pages
-
ATOMIZERS
4 Pages
-
SPRAYERS
4 Pages
-
2016 STANDING EQUINE MRI
8 Pages