HI98129 • HI98130
2Pages

{{requestButtons}}

Catalog excerpts

HI98129 • HI98130 - 1

Accuracy (@25 °C / 77 °F) Temperature compensation Environment TDS factor EC/TDS Calibration Solutions HI98129 HI98130 Electrode Battery type Battery life Auto-off Dimensions Weight Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using the tester. For more information about Hanna Instruments and our products, visit www.hannainst.com or e-mail us at sales@hannainst.com. For technical support, contact your local Hanna Instruments Office or e-mail us at tech@hannainst.com. Preliminary Examination Remove the tester and accessories from the packing material and examine it carefully. If you require any further information, please contact Hanna Instruments technical support team at tech@hannainst.com. Each HI98129 is delivered in a cardboard box and is supplied with: • HI70004 pH 4.01 buffer solution, 20 mL sachet (1 pc.) • HI70007 pH 7.01 buffer solution, 20 mL sachet (1 pc.) • HI70300N Storage solution for pH & ORP electrodes, 20 mL sachet (1 pc.) • HI70031 1413 ^S/cm conductivity standard, 20 mL sachet (1 pc.) • HI70032 1382 ppm TDS standard, 20 mL sachet (1 pc.) • HI700601 pH & ORP electrode cleaning solution, 20 mL sachet (1 pc.) • HI73127 pH electrode • HI73128 Electrode removal tool • 1.5V batteries (4 pcs.) • Instrument quality certificate • Instruction manual Each HI98130 is delivered in a cardboard box and is supplied with: • HI70004 pH 4.01 buffer solution, 20 mL sachet (1 pc.) • HI70007 pH 7.01 buffer solution, 20 mL sachet (1 pc.) • HI70300N Storage solution for pH & ORP electrodes, 20 mL sachet (1 pc.) • HI70030 12880 ^S/cm conductivity standard, 20 mL sachet (1 pc.) • HI70038 6.44 ppt TDS standard, 20 mL sachet (1 pc.) • HI700601 pH & ORP electrode cleaning solution, 20 mL sachet (1 pc.) • HI73127 pH electrode • HI73128 Electrode removal tool • 1.5V batteries (4 pcs.) • Instrument quality certificate • Instruction manual Note: Save all packing material until you are sure that the tester works correctly. Any damaged or defective item must be returned in its original packing material with the supplied accessories. General Description & Intended Use HI98129 & HI98130 are compact pH, EC/TDS and temperature testers. They feature a two-buttons operation system and are easy to use. The compact and waterproof casing is designed to float if accidentally dropped in water. The testers measure temperature in both °C and °F. All pH and EC/TDS measurements are temperature compensated automatically (ATC). EC/TDS measurements have user-selectable EC/TDS conversion factor (CONV) and temperature compensation coefficient (B). The testers display a stability tag (<5) that will disappear once the reading has stabilized. Battery level and low-battery indicator are clearly displayed on the LCD to alert the user in the event that low battery power could adversely affect readings. BEPS (Battery Error Prevention System) Testers will automatically shut off if there is not enough power to get an accurate measurement. pH Probe: HI98129 & HI98130 are supplied together with HI73127 pH replaceable electrode with a stainless steel round connector and extendable cloth junction. This design has no pins to line up or that can break. Temperature Sensor: The stainless steel temperature sensor facilitates faster and more accurate temperature measurement. pH: automatic, one or two-point with two sets of standard buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) EC/TDS: automatic, one-point calibration HI70031 (1413 ^S/cm) HI70032 (1382 ppm; CONV=0.50) HI70442 (1500 ppm; CONV=0.70) HI70030 (12.88 mS/cm) HI70038 (6.44 ppt; CONV=0.50 or 9.02 ppt; CONV=0.70)_ Approx. 100 hours After 8 minutes of non-use 171 x 41 x 26 mm (6.7 x 1.6 x 1.0") ~ 93 g (3.4 oz.)_ 1. Automatic Temperature Compensation (ATC) indicator 3. Battery life percentage indicator Operational Guide Turning the Tester ON / OFF Press and hold cb/MODE. All LCD segments will be displayed for a few seconds followed by battery life percentage indicator. To turn the tester off, from measurement mode, press 6/MODE. "OFF" will be displayed on the second LCD line and then the tester will turn off. HOLD Mode From measurement mode, press and hold SET/HOLD until "HOLD" is displayed. pH, EC/TDS or temperature readings will be frozen on the LCD. Press either buttons to resume measurement mode. Setup Setup mode allows the selection of temperature unit and pH buffer set. To enter the setup mode, select pH mode and press 6/MODE until "TEMP" and the current temperature unit are displayed (e.g. "TEMP °C"). Then: • Press SET/HOLD to select temperature unit. After the temperature unit has been selected, press 6/MODE to select the buffer set. To return to measurement mode, press 6/MODE twice. • After setting the temperature unit, the tester will display the current buffer set: "pH7.01 BUFF" (for pH 4.01/7.01/10.01) or "pH6.86 BUFF" (for NIST pH 4.01/6.86/9.18). Press SET/HOLD to change the buffer set and press 6/MODE to resume measurement mode. pH Calibration & Measurement It is recommended to calibrate the tester frequently, especially if high accuracy is required. More frequent calibrations may be required depending on the type of sample being tested. The tester should be recalibrated: • whenever the pH electrode is replaced • at least once a month • after testing aggressive samples From measurement mode, press and hold 6/MODE until "CAL" is displayed. The tester enters calibration mode and displays "pH 7.01 USE" or "pH 6.86 USE", if NIST buffer was selected. Buffer value will be displayed on the first LCD line and "REC" message will be displayed on the second line. If used buffer was not valid, "USE" message will be displayed for 12 seconds and replaced by "WRNG" indicating measured sample is not valid. • For one-point calibration using pH 4.01, 10.01 or 9.18 buffer solution, once the reading has stabilized, the tester automatically accepts the calibration point. Accepted buffer point and "OK 1" message are displayed and then the tester returns to measurement mode. • For one-point calibration using pH 7.01 (or 6.86) buffer solution, press 6/MODE after calibration point has been accepted. The tester will display "pH 7.01" (or "pH 6.86") and "OK 1" and then return to measurement mode. • For a two-point calibration using pH 7.01 (or pH 6.86) buffer solution, after the first calibration point has been accepted, "pH 4.01 USE" will be displayed for 12 seconds (unless a valid buffer is recognized). • If valid buffer solution is recognized (pH 4.01, 10.01 or 9.18), the calibration point is accepted and the accepted value and "OK 2" are displayed. The tester then returns to measurement mode. • If no valid buffer solution is recognized, "WRNG" message is displayed. Note: When the calibration procedure is completed, the "CAL" tag is turned on. Exiting Calibration & Resetting Default Values • When in calibration mode, it is possible to exit calibration procedure by pressing 6/MODE, before first-point calibration has been accepted. The tester displays "ESC" and returns to measurement mode and last calibrated data. • When in calibration mode, it is possible to clear a previous calibration and return to default values by pressing SET/HOLD, before the first calibration point has been accepted. The tester displays "CLR" on the second LCD line, "CAL&quo

Open the catalog to page 1

All Hanna Instruments catalogs and technical brochures

  1. HI98115

    2 Pages

  2. HI98118

    2 Pages

  3. General Catalogue

    1012 Pages

  4. MANPCA

    80 Pages

  5. General Catalog

    772 Pages