HDG R15/20/25/30
6Pages

{{requestButtons}}

Catalog excerpts

HDG R15/20/25/30 - 1

HDG R15/20/25/30 with HDG Easy-Control Product catalogue Page 6 Gasifying wood boiler for log wood (330/500 mm) additional boiler for existing heating system The HDG R15/20 is a gasifying wood boiler with downward combustion technology. The log wood boiler can be operated with wood up to a third of a metre (HDG R15) or half a metre (HDG R20). The hardwood content must not exceed 30%. The HDG R15/20 is ideal for use as an additional boiler for existing oil, gas or pellet boilers. The HDG R15/20 can also be used in combination with heat pumps or solar energy systems, yielding benefits in terms of efficiency and additional reliability of supply. Equipment features and specifications supplied • High-quality folded fuel chamber inner cladding for long boiler service life • Integrated flue gas extractor in fuel chamber prevents smoke escaping when fuel chamber door is opened • Ergonomic filling due to large fuel chamber door and low door aperture bottom edge • Separate heating door for convenient heating up and cleaning • Multi-part nozzle brick made of fireproof concrete as a guarantee for a long life expectancy • Adjustable primary and secondary air volume for soft and hard wood • Modular-design high-temperature combustion chamber lined with separate firebricks for low-emission recombustion of combustion gases • Long cleaning intervals due to generously dimensioned ash compartment and easy removal of combustion and flue ash to the front into the ash pan using the cleaning tool supplied • Constantly high efficiency due to cleaning turbulators fitted as standard in the upright heat exchanger pipes HDG Easy Control • Exhaust and boiler temperature-controlled combustion and output control with speed-controlled flue gas fan • Return temperature control and accumulator regulation system • Potential-free contact for refuel signal • Large display unit with self-explanatory menu navigation • Four operating keys for setting the operating parameters • Control unit mounted on top of the boiler • Flue gas temperature sensor mounted on flue pipe connection • Supply and return sensors mounted in boiler • Accumulator sensor included Design-type approved to DIN EN 303-5, certified to EU Pressure Equipment Directive 97/23/EC. HDG Bavaria GmbH ■ D-84323 Massing ■ www.hdg-bavaria.com ■ All prices shown, valid from 2021-04-01, are exclusive of services and value added tax. Subject to technical or price changes and corrections. Our general terms and conditions app

Open the catalog to page 1
HDG R15/20/25/30 - 2

HDG R15/20/25/30 with HDG Easy-Control Product catalogue Page 7 System and hydraulic components HDG return temperature control group A DN 25 with energy-efficient pump for HDG R15 16002062 Return temperature control group DN 25 with insulation, Wilo 25/6 energy-efficient circulation pump without display, 180 mm, outside thread DN 40, incl. insulation, DN 25 three-way mixing valve, SM 4.6 actuator, running time 150 seconds, 230 V, 2 ball valves DN 25 inside thread, at side. DN 25 connection for boiler safety set, screw connection/seal HDG return temperature control group A DN 32 with...

Open the catalog to page 2
HDG R15/20/25/30 - 3

Gasifying wood boiler with downward combustion technology The speed-controlled flue gas fan supports the necessary flue vent and provides the required underpressure in the fuel chamber. This makes heating up as well as cleaning a clean and speedy affair. The speed of the flue gas fan is automatically optimised to the situation by the control. The flue gas housing can be rotated and allows flexible mounting to the chimney. The cleaning lid above allows easy access to the upright heat exchanger area. The few cleaning and maintenance tasks can be carried out easily from here. An additional...

Open the catalog to page 3
HDG R15/20/25/30 - 4

Gasifying wood boiler with downward combustion technology Product catalogue The HDG Easy Control is at the top of the boiler and acts as the “brain” of the modern gasifying wood boiler. The connections are easily accessible in the housing of the control element. The prefabricated cable can be easily connected with the necessary components. When the fuel chamber door is opened, the door contact switch is tripped and the flue gas fan starts at full speed. The flue gas extraction in the area above the fuel chamber prevents any carbonisation gases in the fuel chamber from escaping into the...

Open the catalog to page 4
HDG R15/20/25/30 - 5

HDG R15/20/25/30 Technical data Product catalogue Page 10 Boiler type 11 Figures as per type-approval test to DIN EN 303-5 by TOV-Sud 2) Maximum operating temperatures of up to 110 °C can also briefly occur. 3) Observe country-specific guidelines HDG Bavaria GmbH ■ D-84323 Massing ■ www.hdg-bavaria.com ■ All prices shown, valid from 2021-04-01, are exclusive of services and value added tax. Subject to technical or price changes and corrections. Our general terms and conditions apply exclusively.

Open the catalog to page 5
HDG R15/20/25/30 - 6

HDG R15/20/25/30 Technical drawings, minimum distances Product catalogue Installation example: HDG R with fine dust filter OekoTube Inside (Necessity of the filter depends on the fuel type) HDG Bavaria GmbH ■ D-84323 Massing ■ www.hdg-bavaria.com ■ All prices shown, valid from 2021-04-01, are exclusive of services and value added tax. Subject to technical or price changes and corrections. Our general terms and conditions apply exclusively.

Open the catalog to page 6