Breathing filter - 1

Breathing filter Size 0 … 1 Flow, max.: 400 l/min [106 gpm] Connection up to DN 30, up to DN 55 Operating temperature ‒30 °C to +100 °C [–22 °F to 212 °F] ▶ Special highly efficient filter materials ▶ Air filtration in hydraulic and lubricating oil tanks ▶ Prevention of initial damage of pumps, bearings and system components ▶ Filter rating optional 10 μm [10 micron] (paper) or 3 μm [3 micron] (micro glass) Features 1 Ordering code 2, 3 Order example and Preferred types 3 Function, section 4 Technical data 5 Compatibility with permitted hydraulic fluids 5 Areas of application of the breathing and air bleed filter in hydraulic systems 5 Dimensions 6, 7 Mounting, Commissioning, Maintenance 8 Tightening torques 8 Exchanging the cap 8 Directives and standardization 9 Intended use 10 Improper use 10

Open the catalog to page 1
Breathing filter - 2

Ordering code Breathing filter Type FEF 0 01 Filling and breathering filter Filter paper, not cleanable Galvanized steel Hengst Filtration GmbH, RE 51513, Edition: 2021-0

Open the catalog to page 2
Breathing filter - 3

Ordering code Breathing filter Type FEF 1 01 Filling and breathering filter Component series 20 ... 29 (20 ... 29: unchanged installation and connection dimensions) Filter rating in μm Absolute Micro glass, not cleanable Filter paper, not cleanable CED-coated steel Filling strainer, length 100 mm [3.94 in] Side clip Backflow prevention Order example and Preferred types1) Order example Preferred types Material number Further versions are available on request. RE 51513, Edition: 2021-04, Hengst Filtrat

Open the catalog to page 3
Breathing filter - 4

Function, section Combination of flange-mounting filling filter and cap removable over the bayonet lock as air breather with internal filter element. The filter element must be exchanged with the cap. The breathing filters are used in hydraulic systems for filtration of the suction air of the fluid tank. They are designed for installation on fluid tanks. Type FEF 0 By default, the cap (1) is connected via a chain (7) to the base (3). Depending on the process cycles, the air and contamination are drawn into the fluid tank. By use of our breathing filters, air circulation at the fluid tank...

Open the catalog to page 4
Breathing filter - 5

Technical data (For applications outside these parameters, please consult us!) General Installation position Operating temperature range Ambient temperature range Storage conditions Galvanized steel Fibers (organic or inorganic); Polyurethane end disks CED-coated steel Fibers (organic or inorganic); Polyurethane end disks Standard Material NBR-bound cellulose fibers ▶ Flange ▶ Filling strainer Galvanized steel / rating 800 μm ▶ Hexagon socket head cap screw Weight Galvanized steel CED-coated steel Galvanized steel / rating 500 μm Cylinder head screw M5x12 DIN84 Material 4.8 kg [lbs]...

Open the catalog to page 5
Breathing filter - 6

Dimensions: FEF 0 (dimensions in mm [inch]) Chain with rivet secured at flange and air breather Filter rating 800 μm [800 micron] Hengst Filtration GmbH, RE 51513, Edition: 202

Open the catalog to page 6
Breathing filter - 7

Dimensions: FEF 1 (dimensions in mm [inch]) RE 51513, Edition: 2021-04, Hengst Filtration G

Open the catalog to page 7
Breathing filter - 8

Mounting, Commissioning, Maintenance Mounting ▶ Filter connection must correspond to the hole pattern (DIN 24557-2) at the tank. ▶ Position the seal on the hole pattern at the tank, insert the filling strainer and apply the second seal. ▶ Over the flange, all parts are fitted at the tank. For this purpose, the screws included in the scope of delivery (see tightening torques) must be used. ▶ Screw-in the cap in clockwise direction (see tightening torques). ▶ We recommend a minimum clearance of 140 mm [5.51 inch] between filter and oil level. Commissioning For commissioning of the system, no...

Open the catalog to page 8
Breathing filter - 9

Directives and standardization Product validation Hengst filters, the filter elements built into them and filter accessories are tested and quality-monitored according to different ISO test standards: Filtration performance test (multipass test) Compatibility with hydraulic fluid The development, manufacture and assembly of Hengst industrial filters and Hengst filter elements is carried out within the framework of a certified quality management system in accordance with ISO 9001:2015. Classification according to the Pressure Equipment Directive Hengst FEF1 breathing and air bleed filters...

Open the catalog to page 9
Breathing filter - 10

Intended use This filter consists of a filter cap with bayonet lock and filter element, base and filling strainer which serve as components in the sense of the EC Machinery Directive 2006/42/EC in hydraulic machinery for the separation of dirt particles. This filter may be used under the following boundary conditions and limits: ▶ Only in systems with fluids of group 2, according to Pressure Equipment Directive 2014/68/EU. ▶ Only according to the application and environmental conditions in the section “Technical data” ▶ Only in compliance with the specified performance limits in the section...