Tank mounted return line filter
30Pages

{{requestButtons}}

Catalog excerpts

Tank mounted return line filter - 1

Tank mounted return line filter with filter element according to DIN 24550 Size according to DIN 24550: 0040 to 1000 additional sizes: 2000, 2500 Nominal pressure 10 bar [145 psi] Connection up to 4” Operating temperature ‒10 °C to +100 °C [14 °F to 212 °F] The tank mounted return line filters are designed for installation on fluid tanks. Their function is to separate solid materials from fluids. Features 1 Ordering code filter 2 ... 5 Preferred types 6 Ordering code accessories 7 ... 9 Filter design 10 Symbols 11 Function, section 12 Technical data 13, 14 Compatibility with permitted hydraulic fluids 14 Dimension 15 ... 18 Options 19 Maintenance indicator 20 Ordering code spare parts 21 ... 23 Assembly, commissioning, maintenance 24, 25 Tightening torques 25 Directives and standardization 26 ... 28 They distinguish themselves by the following: ▶ Filter for tank mounting ▶ Special highly efficient filter materials ▶ Filtration of very fine particles and high dirt holding capacity across a broad pressure differential range ▶ High collapse resistance of the filter elements ▶ Optionally equipped with mechanical optical maintenance indicator with memory function ▶ Available as an option with different electrical switching elements, modular design ▶ By default, the filters are equipped with a bypass valve integrated in the filter housing ▶ Optional measuring port

Open the catalog to page 1
Tank mounted return line filter - 2

10TEN0040-1000; 10TE2000/2500 | Tank mounted return line filter Ordering code filter Sizes 0040 to 0100 01 Return line filter, simple 10 bar [145 psi] With filter element according to DIN 24550 TEN... Filter element according to DIN 24550 Filter rating in µm Nominal Stainless steel wire mesh, cleanable Glass fiber material, not cleanable Max. admissible pressure differential of the filter element 30 bar [435 psi] ‒ Filter with bypass valve Without maintenance indicator ‒ bypass cracking pressure 3.5 bar [51 psi] Pressure gauge 0…6 bar [0…87 psi] right ‒ bypass cracking pressure 3.5 bar [51...

Open the catalog to page 2
Tank mounted return line filter - 3

Tank mounted return filter | 10TEN0040-1000; 10TE2000/2500 3/30 Ordering code filter Sizes 0040 to 0100 01 Main inlet Frame size Standard connection Alternative connection Supplementary information (Multiple specifications possible) 09 Breathing filter Ventilation filter with surge protection Threaded coupling right (not possible with pressure gauge right) without bypass valve Outlet pipe L250 mm [9.8 inch] Order example: 10TEN0040-PWR10A00-P2,2-M-R3 Further versions (filter materials, connections,...) are available on request.

Open the catalog to page 3
Tank mounted return line filter - 4

10TEN0040-1000; 10TE2000/2500 | Tank mounted return line filter Ordering code filter sizes 0160 to 2500 01 Return line filter, simple 10 bar [145 psi] With filter element according to DIN 24550 (only with frame size 0160 - 1000) Size TEN... Filter element according to DIN 24550 TE... (Filter elements according to Hengst standard) Filter rating in µm Nominal Stainless steel wire mesh, cleanable Glass fiber material, not cleanable Max. admissible pressure differential of the filter element 30 bar [435 psi] ‒ Filter with bypass valve Without maintenance indicator ‒ bypass cracking pressure 3.5...

Open the catalog to page 4
Tank mounted return line filter - 5

Tank mounted return filter | 10TEN0040-1000; 10TE2000/2500 5/30 Ordering code filter sizes 0160 to 2500 01 Main inlet Frame size Standard connection Alternative connection Supplementary information (Multiple specifications possible) Threaded coupling left (not possible with pressure gauge left) without bypass valve Order example: 10TEN0630-PWR10A00-P2,2-M-S9 Further versions (filter materials, connections,...) are available on request.

Open the catalog to page 5
Tank mounted return line filter - 6

10TEN0040-1000; 10TE2000/2500 | Tank mounted return line filter Preferred types Filter rating 3 μm, 6 µm, 10 µm and 20 µm Filter type Flow in l/min [gpm] with ν = 30 mm2/s [142 SUS] and Δp = 0.5 bar [7.25 psi] 1) An appropriate differential pressure via the filter and measuring device according to ISO 3968. Th

Open the catalog to page 6
Tank mounted return line filter - 7

Tank mounted return filter | 10TEN0040-1000; 10TE2000/2500 7/30 Ordering code accessories Electronic switching element for maintenance indicators If an electronic switching element with signal suppression up to 30 °C [86 °F] is used (WE-2SPSU-M12 X 1, R928028411), it has to be ensured that the aluminum version of the mechanical-optical maintenance indicator must be used. These maintenance indicators are referred to in the filter type key as “V0.8”, “V1.5” or “V2.2”. Also refer to the chapter "Spare parts and accessories". The temperature-controlled signal processing does not work with...

Open the catalog to page 7
Tank mounted return line filter - 8

10TEN0040-1000; 10TE2000/2500 | Tank mounted return line filter Ordering code accessories (dimensions in mm [inch]) Mating connectors according to IEC 60947-5-2 Mating connector suitable for K24 4-pole, M12 x 1with screw connection, cable gland Pg9. for electronic switching element with round plug-in connection M12 x 1 Material no. R900031155 54 [2.12] Mating connector suitable for K24-3m 4-pole, M12 x 1with potted-in PVC cable, 3 m long. Line cross-section: 4 x 0.34 mm2 Core marking: 1 brown 2 white 3 blue 4 black Material no. R900064381 For more round plug-in connections and technical...

Open the catalog to page 8
Tank mounted return line filter - 9

Tank mounted return filter | 10TEN0040-1000; 10TE2000/2500 9/30 Ordering code accessories (dimensions in mm [inch]) Outlet pipes Outlet pipe, pluggable, size 0040-0100 The outlet pipes are plugged onto the filter bowl outlet piece. Correct seat is confirmed by an audible click. After plug-on, the outlet pipe can no longer be removed. Outlet pipe, with threaded connection from size 0160 45¡ Recommended distance to tank bottom (unless otherwise specified): 60…160 mm [2.4…6.3 inch] From a pipe length of 400 mm [15.75 inch] , we strongly recommend fixing the outlet pipe by means of a...

Open the catalog to page 9
Tank mounted return line filter - 10

10TEN0040-1000; 10TE2000/2500 | Tank mounted return line filter Filter design Easy selection of the filter size is made possible by the FilterSelect online tool. The filter can be designed using the operating pressure, flow and fluid system parameters. The required filter rating is based on the application, the sensitivity to contamination of the components and the environmental conditions. The program leads you through the menu on a step-by-step basis. A documentation of the filter selection can finally be created in the form of a PDF file. This file contains the entered parameters, the...

Open the catalog to page 10