triton

triton
1 / 11 PagesView full catalog

triton

Product catalog summary
Hydrodynamic Design and Technology
Hidroconta's Triton water meter utilizes multi-jet technology for uniform load distribution on the turbine, facilitated by a water inlet diffuser. This design activates a magnetic transmission for accurate volume readings.
MID Approval
The Triton water meter complies with the European Directive 2014/32/EU, ensuring it meets metrological standards for domestic water consumption. Rigorous testing is conducted to maintain quality and accuracy.
Technical Specifications
  • Constructed with thermoplastic materials for turbine and dial.
  • Features a vacuum dial to prevent condensation.
  • Magnetic transmission is shielded against external magnetic fields.
  • Equipped for remote reading with an inductive pulse output.
  • High mechanical and wear resistance.
  • No need for straight sections at input or output (U0-D0).
Installation and Operation
  • Water meters should be installed at a lower level relative to the pipe slope to prevent air pockets.
  • Minimum pressure of 0.3 bar is recommended at the outlet.
  • Includes installation instructions for optimal performance and maintenance.
Materials and Construction
  • Components include ABS cover and casing, iron anti-fraud ring, stainless steel threaded ring, and copper alloy or composite body.
Dimensions and Packing
  • Available in sizes DN15, DN20, and DN25 with specific dimensions and weights for brass and composite materials.
Communication and Smart Metering
The IRIS communications module enables automatic remote readings, integrating with IoT systems. It supports various communication technologies, including GPRS and LoRaWAN, for versatile installation needs.
Alarms and Monitoring
  • Includes alarms for under-dimensioned water meter, tampering, battery status, reverse flow, leakage, and stopped meter.
FAQs
  • Differences between dry, wet, and semi-dry dial water meters.
  • Measurement ranges and precision as per MID Directive.
  • Installation guidelines for multijet water meters.
See more

Catalog excerpts

triton-1

WHEN WATER COUNTS water meter

 Open the catalog to page 1
triton-2

WHEN WATER COUNTS Convertible into a Smart meter Brass or composite manufactured Starting flow form 10 l/h Magnetic transmission Installation UO/DO Hydrodynamic design Multi-jet Technical specifications uniform Turbine and dial in thermoplastic material. distribution of load on the turbine lthanks Vacuum dial to prevent condensation of water. to the water inlet diffuser. The movement activates the magnetic transmission that will give the final reading of the volume. magnetic fields. Inductive pulse output pre-equipment for a remote Hidroconta’s Triton water meter complies High mechanical and...

 Open the catalog to page 2
triton-3

WHEN WATER COUNTS High protection Hidroconta’s Triton water meters are designed The dial of the meter has a pre-installation that allows the to avoid external manipulation by magnetic installation of a pulse emitter, without the need to stop fields. They have a special shielding that the meter, this will give information on the reading. prevents any possible fraud in the transmission and therefore in the result of the reading. MID approval for drinking water Water meter serial number Inductive pulse output Permanent flow rate Horizontal working range Maximum working pressure Installation conditions...

 Open the catalog to page 3
triton-4

WHEN WATER COUNTS Anti-fraud ring Threaded ring Stainless steel Flat washer Pressure plate Flat seal Copper alloy or composite All rights reserved. © Copyright. 2023 HIDROCONTA. S.A.U.

 Open the catalog to page 4
triton-5

WHEN WATER COUNTS WEIGHT WITH FITTINGS WEIGHT WITHOUT FITTINGS THREADED CONNECTIONS GROSS WEIGHT All rights reserved. © Copyright. 2023 HIDROCONTA. S.A.U. WATER METER MATERIAL Brass Composite Brass Composite Brass

 Open the catalog to page 5
triton-6

WHEN WATER COUNTS Pulse output Compatible with wired pulse output (ARCE). Pulse value Maximum resistance activated Maximum load voltage Maximum load current Insulation voltage test White = common. Blue = positive pulse. Red = negative pulse. RELAY CHARACTERISTICS Installation diagrams Installation instructions Water meters should always be operated full Provide a shut-off valve upstream of the water of water. A minimum pressure of 0.3 bar is meter to facilitate maintenance and/or repair of the recommended at the outlet of the meter to ensure that it is completely filled with water. Install at...

 Open the catalog to page 6
triton-7

WHEN WATER COUNTS Working conditions WATER TEMPERATURE RANGE Maximum permissible error MAXIMUM PRESSURE Technical specifications STARTING FLOW RATE MINIMUM READING Pressure loss curve 15mm 20mm MAXIMUM READING m3 Brass Composite Brass Composite Brass Flow error curve 25mm All rights reserved. © Copyright. 2023 HIDROCONTA. S.A.

 Open the catalog to page 7
triton-8

WHEN WATER COUNTS Automatic meter reading Adding the IRIS communications module to the water meter will enable automatic remote readings. IRIS devices allow mechanical meters to access the world of IoT communications. Its great versatility allows it to be integrated with a wide range of meters. The IRIS communications module is integrated with the Demeter system. It supports the integration of a wide range of devices using various communication technologies to suit the needs of the installation. DEMÉTER WEB APP HIDROCONTA METERING Transmission power Firmware Update LoRaWAN Configuration GPRS...

 Open the catalog to page 8
triton-9

WHEN WATER COUNTS Alarms Under-dimensioned water meter alarm: Reverse flow alarm: the Detection of flow rate higher than the overload flow inductive pulse version. Configuration adjusted by rate for a maximum period of time. Configuration Water meter tampering alarm (tampering): The alarm is triggered in case the device is not maximum period of time. Configuration adjusted by mounted on the meter. Only available for the inductive pulse version. Optional upon request. Battery status alarm: Water meter stopped alarm: The alarm is activated if no consumption is detected Various battery alarm levels...

 Open the catalog to page 9
triton-10

WHEN WATER COUNTS FAQs 1. Which is the diference between dry dial, wet dial and semi-dry water meter dial? On water meters with dry dial the reading mechanism (clock) is tightly separated from the wet chamber of the meter. On Wet dial water meter the watch is totally immersed in the fluid. For water meters with semi-dry dial, the reading mechanism is totally immersed in the fluid but the dial is partially separated and protected by a sealed capsule. 2. What are the ranges of measurement and precision? The measuring range of the meters is determined by the Directive MID 2014/32 / UE establishing...

 Open the catalog to page 10
triton-11

WHEN WATER COUNTS water meter Hidroconta disclaims liability for errors in the information contained in this document, which is subject to change without notice. All rights reserved. Copyright. 2023 HIDROCONTA. S.A.U.

 Open the catalog to page 11

All HIDROCONTA S.A. catalogs and technical brochures

  1. fenix

    11  Pages

  2. Hidrojet

    10  Pages

  3. MFSM-L

    10  Pages

  4. Atlantis.v6

    10  Pages

  5. HIDROMAG

    10  Pages

  6. Dosing pumps

    6  Pages

  7. Hidromatic

    15  Pages

  8. Atlantis

    10  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.