Overview: The I8-40A Medical Incinerator is a small-scale, controlled air incinerator designed for optimal combustion of various waste types. Its top-loading design ensures liquid retention, making it suitable for diverse waste incineration. The unit includes a secondary chamber with an afterburner, providing a 2-second retention time for re-burning harmful emissions.
Emission Data: The incinerator meets EU standards for emissions. Key parameters include:
  • Total dust: 12 mg/m3 (limit: 30 mg/m3)
  • Sulphur dioxide: 2.4 mg/m3 (limit: 200 mg/m3)
  • Nitrogen dioxide: 60 mg/m3 (limit: 400 mg/m3)
  • Carbon monoxide: 78.3 mg/m3 (limit: 100 mg/m3)
Technical Data:
  • Operational Specifications:
    • Combustion Chamber Volume: 0.36 m3
    • Burn Rate: 20 kg per hour
    • Average Fuel Consumption: 9 kg
    • Operational Temperature: 850 - 1320°C
    • Gas Retention in Secondary Chamber: 2 seconds
    • Temperature Monitoring: Yes
    • Average Ash Residue: 3%
    • Thermostatic Device: Yes
  • Physical Specifications:
    • External Length: 1220 mm
    • External Width: 910 mm
    • External Height: 4200 mm
    • Shipping Weight: 1520 kg
See more

Catalog excerpts

I8-40A Medical Incinerator-1

INCINER8 I8-40A Medical Incinerator Summary I8-40A model is a small scale incinerator. This model is a controlled air incinerator, providing optimal combustion conditions for different waste types. Top loading design provides liquid retention making this incinerator ideal for incineration of many different waste types. This unit benefits from a secondary chamber with afterburner for the re-burn of harmful emissions with a 2 second retention time. Emission Data Average emissions / EU standards On basic incinerators (with secondary chamber) Parameter Total dust Sulphur dioxde Nitrogen dioxde* Carbon monox de Technical Data Operational Specs Physical Specs Combustion Chamber Volume (m3) 0.36m3 External Length (mm) 1220mm Burn Rate 20 kg per hour External Width (mm) 910mm Average Fuel Consumption 9 kg External Height (mm) 4200mm Gas Retention in Secondary Chamber 2 secs Temperature Monitoring Yes Thermostatic Device Yes Extras: Options: Systems

 Open the catalog to page 1

All Inciner8 catalogs and technical brochures

  1. i8-40B

    7  Pages

  2. i8-55B

    7  Pages

  3. i8-M250

    7  Pages

  4. i8-M700

    7  Pages

  5. i8-PC2

    7  Pages

  6. I8-sirocco

    2  Pages

  7. i8-M70

    7  Pages

  8. i8-M50

    7  Pages

  9. i8-M40

    7  Pages

  10. i8-M15

    7  Pages

  11. i8-M20

    7  Pages

  12. I8-700

    2  Pages

  13. I8M-15

    2  Pages

  14. I8M-60

    2  Pages

  15. I8M-120

    2  Pages

  16. I8-10S

    2  Pages

  17. I8-20S

    2  Pages

  18. I8-20A

    2  Pages

  19. I8-40S

    2  Pages

  20. I8-40A

    2  Pages

  21. I8-55S

    2  Pages

  22. I8-55A

    2  Pages

  23. I8-75S

    2  Pages

  24. I8-75A

    2  Pages

  25. I8-140

    2  Pages

  26. I8-200

    2  Pages

  27. I8-250

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.