1. Catalogs
  2. Innoquest, Inc.
  3. PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER

PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER

PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER

PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER

Product catalog summary
Safety Information
Exercise caution when using the Digital Soil Compaction Meter to avoid damaging underground utilities. Always use the included tip cover during transport to prevent injury or damage.

Meter Diagram
The meter includes a stainless steel shaft with depth marks, a splash/dust-proof digital display, a replaceable tool steel tip, and a battery compartment in the handle.

Features
The meter meets ASABE S313.3 standards and displays maximum compaction values automatically. It features a color-coded display for easy reference, high-resolution electronic force sensor, and rugged design for field use. Measurements can be displayed in PSI or kPa.

Specifications
Usable probe length is 30 inches, with a range of 0 to 825 PSI. The meter is waterproof with an IP64 rating and operates in temperatures from 32-120°F. It is constructed with a solid machined plastic body and stainless steel shaft.

General Operation
Installing Batteries: Use two AA batteries, ensuring correct orientation.
Zero Calibration: Hold the meter above ground and press the ZERO button to calibrate.
Changing Display Units: Press POWER and ZERO buttons simultaneously.
Taking a Reading: Ensure a steady penetration rate of 1.2 in./second for accuracy. The maximum reading is displayed upon probe withdrawal.
Probe Tip Cover: Use the cap for protection during transport.
Probe Tip Replacement: Replace the tip when the diameter is less than 0.490 inches.

Troubleshooting & Maintenance
If error messages appear, ensure the meter is vertical and retry zeroing. Clean the meter with a damp cloth as needed.

Warranty & Service
The product has a one-year warranty against defects. Returns require an RMA number, and the customer is responsible for shipping costs. Non-warranty repairs incur a minimum charge.
See more

Catalog excerpts

PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER-1

Digital Soil Compaction Meter Innoquest Item # 29360 Product Manual

 Open the catalog to page 1
PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER-3

1.0 Safety Info Use caution when probing into soil to avoid hitting buried electrical wires or other utilities. Use caution when handling and transporting this meter since its sharp metal tip could cause damage to packaging, containers, or personal. Always use the included tip cover when transporting the meter. (See section 5.5 for more info) 2.0 Meter Diagram Color Coded Bar Graph Display Power Button Zero Button Battery Compartment In Handle Splash/Dust Proof Digital Display Stainless Steel Shaft with Depth Marks Extra Hard Tool Steel Tip (Replaceable)

 Open the catalog to page 3
PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER-4

Meets ASABE S313.3 Soil Compaction Standard Automatically displays maximum compaction value when probe is extracted from the soil. Color coded display for easy compaction reference Green 0-200 PSI (0-1400 kPa) Yellow 200-300 PSI (1400-2070 kPa) Red 300+ PSI (2070+ kPa) The high resolution of the electronic force sensor assures accurate compaction values in soft soils with 1/2in.(12mm) cone. Rugged design & rubber protector for repeated field use Stainless steel shaft with depth marking every 4in.(10cm) Ultra-hard tool steel cone for years of service 4.0 Specifications Usable Probe length: 30in....

 Open the catalog to page 4
PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER-5

5.0 General Operation 5.1 Installing the Batteries Remove the metal end cap on the meter’s handle with a straight screw driver. Install two (2) new alkaline AA or LR6 size batteries with the plus (+) side of both batteries facing into the tube. Replace the metal end cap with the spring contacting the negative (-) of the last battery. When it is time to replace the batteries a low battery symbol ( ) will show on the unit’s display. Zero Button With the meter powered on, hold the meter above the ground with the shaft facing down. Press the ZERO button and continue holding the meter steady and above...

 Open the catalog to page 5
PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER-6

5.3 Changing Display Units Pressing both buttons (POWER & ZERO) at the same time while the meter is on will change the displayed units. This change will be saved when the meter is turned off. 5.4 Taking a Reading Power on the meter by pressing the POWER button. Zero the meter if necessary with the ZERO button. Slowly press the meter into the soil with a firm and steady pressure. Do not stop or reverse force on the meter until the desired depth has been reached. Keeping the meter vertical during the entire penetration sequence assures readings are true cone pressures and not a result of side loading...

 Open the catalog to page 6
PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER-7

5.5 Probe Tip Cover The meter ships with a re-usable probe tip cap. This cap can be stored in the meter’s handle while the meter is in use. The use of this probe tip cap is recommended for protecting the probe tip, personal, and vehicles during transport. 5.6 Probe Tip Replacement The probe tip is replaceable. It can be unscrewed from the shaft by using pliers to grip the shaft and cone respectively. The cone is attached with removable type thread locker, so some force may be required to loosen it. The probe tip should be replaced when the diameter of the cone’s base measures less than 0.490in.(12.45mm)...

 Open the catalog to page 7
PRODUCT MANUAL: SPOTON® SOIL COMPACTION METER-8

7.0 Warranty & Service One Year Warranty Innoquest, Inc. warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one (1) year from date of purchase. This warranty extends only to the original purchaser and shall not apply to any product which, in Innoquest’s sole opinion, has been subject to misuse, alteration, abuse, or abnormal conditions of operation or handling. Innoquest’s obligation under this warranty is limited to repair or replacement of the product which is returned to Innoquest. Innoquest accepts no liability for whatever...

 Open the catalog to page 8

All Innoquest, Inc. catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.