Overview: This document outlines the technical specifications and operational guidelines for the Hengli hydraulic directional solenoid valve, Type WE 6...L6X, used to control the start, stop, and direction of flow in hydraulic systems.
Specifications: The valve is a direct-operated directional solenoid valve with a porting pattern compliant with DIN 24 340 form A, ISO 4401, and CETOP-RP 121 H standards. It features wet-pin AC or DC solenoids with a detachable coil, allowing coil changes without opening the pressure-tight chamber. It supports both individual and central electrical connections, with a nominal size of 6, and operates up to 350 bar and 80L/min.
Function and Configurations: The valve includes a housing, one or two solenoids, a control spool, and return springs. In its de-energized state, the control spool is held in a neutral position by return springs. The spool is actuated via wet pin solenoids, with an optional manual override button. Configurations include versions with two spool positions and solenoids with or without detent.
Ordering Code: A detailed ordering code system is provided, specifying options for solenoid types, voltage, manual override, seals, and throttle inserts. Various spool symbols and configurations are available to meet different operational needs.
Technical Data: The valve operates in temperatures from -30 to +50°C with NBR seals and -20 to +50°C with FKM seals. It supports a maximum operating pressure of 350 bar at ports A, B, and P, and 210 bar (DC) or 160 bar (AC) at port T. It is compatible with mineral oil and phosphate ester fluids, with a viscosity range of 2.8 to 500 mm²/s.
Performance Limits: Performance limits are detailed for various solenoid configurations and spool symbols, with characteristic curves provided for flow and pressure differentials.
Unit Dimensions: Detailed dimensions are provided for valves with both DC and AC solenoids, including space requirements for connector and coil removal, and specifications for securing nuts and valve fixing screws.
See more

Catalog excerpts

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-1

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid Ordering code Characteristic curves Technical data Electric data Performance limits Unit dimensions - Direct operated directional solenoid valve, standard version - Porting pattern according to DIN 24 340 form A, ISO 4401 and CETOP-RP 121 H - Wet-pin AC or DC solenoids with detachable coil - Pressure-tight chamber needs not to be opened for a coil change - Electrical connection as individual or central connection

 Open the catalog to page 1
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-2

Hengli hydraulic | Hydraulic components Directional valve | Type WE 6...L6X Type WE valves are solenoid operated directional spool valves. They control the start, stop and direction of flow. The directional control valves consist of housing (1), one or two solenoids (2), the control spool (3), and one or two return springs (4). In the de-energized condition the control spool (3) is held in the neutral or initial position by means of return springs (4) (except for impulse spools). The control spool (3) is actuated via wet pin solenoids (2). To ensure proper operation, care must be taken that the...

 Open the catalog to page 2
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-3

Directional valve | Type WE 6...L6X Hydraulic components | Hengli hydraulic Ordering code 3 ways = 3 (For spool A and B) 4 ways = 4 Further details in clear text No code=Without locating hole /60= With locating hole /62=With locating pin hole ISO 8752-3×8-St Directional valve with wet pin solenoids No code = NBR seals V = FKM seals Series L60 to L69 =L6X ( L60 to L69: unchanged installation and connection dimensions) No code = Without throttle insert B08 = Throttle Φ0.8 mm B10 = Throttle Φ1.0 mm B12 = Throttle Φ1.2 mm B15 = Throttle Φ1.5mm B20 = Throttle Φ2.0 mm B25 = Throttle Φ2.5 mm B30 = Throttle...

 Open the catalog to page 3
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-4

04/10 Hengli hydraulic I Hydraulic components Spool valve symbols Spool valve symbols A B (PortT asdrain port) (Port T asdrain port) (Port T as drain port) Notes: Spool symbolsA9, B9, D9,Y9 are onlyfor type winioult .../O... and .../(OF... and areonlyuesd as fi.ilot valves Spool valve symbols A B 1 Example: If solenoid is fixed at position ‘a’, V Ii 1|| 1P>67 =M2 tile ordermgcode is...EA Characteristic curves (Measured at 5o„=40X ±5°C, using HLP46) 7 Symbol "R" in switched positions B ^ A 8 Symbol "G" and "T" in neutral position P ^ T 9 Symbol "H" in neutral position P ^ T

 Open the catalog to page 4
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-5

Directional valve I Type WE 6...L6X Hydraulic components I Hengli hydraulic 05/10 Caution: When connecting wires, properly connect the PE conductor (PE 4- ) . ( For other type voltage please consult us. )

 Open the catalog to page 5
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-6

Hengli hydraulic | Hydraulic components Performance limits Directional valve | Type WE 6...L6X (Measured at ϑoil =40℃ ±5℃ , using HLP46) The specified switching performance limits are valid with two directions of flow (e.g. from P to A and simultaneous return flow from B to T). Due to the flow forces acting within the valve, the permissible switching performance limit can be significantly lower with only one direction of flow (e.g. from P to A, with port B being closed)! The switching performance limit was determined with the solenoid at operating temperature, at 15 % under-voltage and without...

 Open the catalog to page 6
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-7

Directional valve I Type WE 6...L6X Hydraulic components I Hengli hydraulic 07/10 Performance limits (Measured at 5oU =40°C±5°C, using HLP46)

 Open the catalog to page 7
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-8

Hengli hydraulic | Hydraulic components Directional valve | Type WE 6...L6X Unit dimensions Valve with DC or rectification AC solenoid 5 1 Solenoid 2 Manual override button 3.1 Plug-in connector to DIN 43 650 3.2 Deutsch connector assembly 4 Junction box with lead and light, M22×1.5 interface 5 Nameplate 6 O-ring: 9.25×1.78 7 Plug screw for valves with one solenoid 8 Space required to remove connector 9 Space required to remove coil 10.1 Dimension of 3-position valves, standard version 10.2 Dimension of 3-position valves, large-scope Type of voltage Requirement for mounting surface Notes: 4 hexagon...

 Open the catalog to page 8
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-9

Directional valve | Type WE 6...L6X Hydraulic components | Hengli hydraulic Unit dimensions Valve with AC solenoid 5 Requirement for mounting surface 1 Solenoid 2 Manual override button 3 Plug-in connector to DIN 43 650 (rotatable 90° ) 4 Junction box with lead and light, M22×1.5 interface 5 Nameplate 6 Seal rings 9.25×1.78 7 Plug screw for valves with one solenoid 8 Space required to remove connector 9 Space required to remove coil 10 Securing nut, tightening torque, MA = 4 Nm 11 Valve fixing screws. Hexagon socket head cap screw M5×50 GB/T 70.1-10.9, Tightening torque MA =8.9Nm Notes: 4 hexagon...

 Open the catalog to page 9
4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid-10

Hengli hydraulic | Hydraulic components Directional valve | Type WE 6...L6X © This brochure can be reproduced, edited, reproduced or transmitted electronically without the authorization of Hengli Hydraulic Company. Due to the continuous development of the product, the information in this brochure is not specific to the specific conditions or applicability of the industry, thus, Hengli does not take any responsibility for any incomplete or inaccurate description.