
Option Specifications FW-100 can be installed within the FD-800 to reduce errors caused by the influence of external airpflow on the high precision balance. Further, since a deodorizing filter is provided on its upper portion, it is also possible to reduce odours created during heat drying. Radiation thermometer calibration kit FDL-01" and MS Excel® are installed, it is possible to transfer and save the measurement data to the PC in real time. Also, it is possible to display the recorded measurement data graphically, so that the moisture and temperature condition changes can be visually confirmed. The graph can show the moisture, thermistor (T1) temperature, and radiation thermometer (T2) temperature. in which the "Data logger software Moisture Analyzer Infrared Moisture Analyzer Model FD-800 Safety precautions • For safe operation, ensure you read the Operating Manual before use. • Do not attempt to measure material that will cause dangerous chemical reactions on heating. Further, the tester becomes very hot, so please take precautions against burns and/or fire. *1 Material that will not cause dangerous chemical reactions when heated. *2 As per Kett's in-house stipulated measurement conditions and standard samples. *3 If the T1 temperature exceeds 180 °C during a measurement, the set temperature may not be achieved. KETT ELECTRIC LABORATORY1-8-1 Minami-Magome, Ota-ku, Tokyo 143-8507, JAPAN S+81-3-3776-1121 +81-3-3772-3001© http://www.kett.co.jp/ E3 [email protected] Contact Management system enhancement department of the Japanese Standards Association (JSA) registers the Quality Management System of the above organization, with conform to JIS Q 9001, ISO 9001. Design, development and production management, calibration and repair of Moisture testers, NIR composition analyzers, Grain inspectors and Coating thickness testers. LVEGETABLE This document is printed using vegetable oil based ink and recycled paper in WL INK consideration for the environment. To improve the product, specifications and the external appearance may be changed without notice. In addition, please note that due to printing, the product's color may appear different from the actual article. KETT ELECTRIC LABORATORY
Open the catalog to page 1FD-800 is an instrument positioned at the top of Kett's infrared moisture analyzer series. It employs a revolutionary dual temperature sensor method to enable high precision moisture measurements. Conventional models measured the temperature within the drying chamber by using a thermistor, and controlled the heat drying temperature. Temperature measurement using thermistors is a procedure that is stable, and known to be reliable through years of experience. However, with a demand for an even more accurate moisture measurement, problems such as the temperature of the sample following the environmental...
Open the catalog to page 219 Pages
2 Pages
2 Pages
2 Pages
2 Pages
36 Pages