NIR Composition Analyzer KB-270
2Pages

{{requestButtons}}

Catalog excerpts

NIR Composition Analyzer KB-270 - 1

• Comparison between reference value by official method and predicted value by KB-270 • Options Thermal printer with 58 mm of paper width, measured results can be immediately printed. * The following is only an example of the test results of creating a calibration curve. Therefore, the following does not guarantee the same results by using the same type of sample. Sample: cookie; content: moisture Sample: flour; content: protein Correlation coefficient: 0.997; standard error: 0.135 Reference value (%) Correlation coefficient: 0.999; standard error: 0.070 Correlation coefficient: 0.997; standard error: 0.115 Large petri dish (150 mm dia) Masking holder (arbitrary hole diameter) + small petri dish (30 mm dia) Reference value (%) Correlation coefficient: 0.991; standard error: 0.172 • Specifications Measurement method Near-infrared reflection, light projected/ received at bottom plate 50 (1 CH. x 4 compositions or contents, simultaneous measurement) Measuring time Normal measurement: 7 sec. (subject to setting) Continuous measurement: at intervals of 0.5 sec. Light source Tungsten lamp Temp./humidity operating range Power supply Reflective plate Deep type light shielding cover Filter spectroscopy Measurement spot Sample: flour; content: carbohydrate Sample: milk; content: milk fat Composition Analyzer Light shielding cover, petri dish with 90 mm dia for samples, sample holder, zero-adjustment plate, power cable, spare fuse, wireless LAN router, PC software, and operating manual Contact 1-8-1 Minami-Magome, Ota-ku, Tokyo 143-8507, JAPAN +81-3-3776-1121 +81-3-3772-3001 http://www.kett.co.jp/ overseas@kett.co.jp Management system enhancement department of the Japanese Standards Association (JSA) registers the Quality Management System of the above organization, with conform to JIS Q 9001, ISO 9001. The scope of the registration. Design, development and production management, calibration and repair of Moisture testers, NIR composition analyzers, Grain inspectors and Coating thickness testers. To improve the product, specifications and the external appearance may be changed without notice. In addition, please note that due to printing, the product's color may appear different from the actual article. 1905•KA•0101•001K Four compositions reveale

Open the catalog to page 1
NIR Composition Analyzer KB-270 - 2

NIR Composition Analyzer model KB-270 Composition and content analysis generally consumes significant time. The data amount that can be obtained in a day, even using good analysis methods, has limitations. However, the time to be used can be reduced. -- A near-infrared analyzer enables reducing the time. If calibration curves correlated with composition and content analysis values are registered in the nearinfrared analyzer in advance, the composition and content percentage can be measured in a few seconds. Simultaneously display four composition and content analysis results! This product,...

Open the catalog to page 2

All Kett Electric Laboratory Co. Ltd. catalogs and technical brochures

  1. TR-260

    2 Pages