TH 210-R
4Pages

{{requestButtons}}

Catalog excerpts

TH 210-R - 1

DATA SHEET Humidity and temperature transmitter Stainless steel or polycarbonate probes Two 4-wire analogue output 0-5/10 V or 0/4-20 mA ABS V0 IP65 housing, with or without display • Power supply 24 Vdc/Vac or 100240 Vac with galvanic insulation • “¼ turn” system mounting with wall-mount plate • Calculated parameters absolute humidity, dew point, combination ratio, wet temperature and enthalpy • Trend indicator Power supply / Output B: 24 Vac/Vdc H: 100-240 Vac Display O: with display N: without display Mounting of the probe S: ambiant D: remote Type of probe I: stainless steel(1) P: polycarbonate Probe length (mm) Relay outputs Probe cable length 150: remote (remote models only) 300: remote ( ): cable lentgh 2 m (standard model) 05M: cable length 5 m Example: TH 210 – BNDP150 – R: Temperature and humidity transmitter, 24 Vac/Vdc power supply, without display, with remote 150 mm 10M: cable length 10 m polycarbonate probe, cable of 2 m length and relay outputs. Important note: the TH 210 – H model (100-240 Vac) is only available with display. Technical specifications Parameter Measuring range Accuracy (Repeatability, linearity, hysteresis): ±1.5% RH (from 5 to 95% RH and from 15 °C to 25 °C) Temperature dependence: ±0.04 x (T-20)% RH (if T<15 °C or T>25 °C) Response time: < 10 seconds (from 10 to 80% RH, Vair = 2 m/s) Response time: < 10 seconds (from 10 to 80% RH, Vair = 2 m/s) Response time: < 10 seconds (from 10 to 80% RH, Vair = 2 m/s) Response time: < 10 seconds (from 10 to 80% RH, Vair = 2 m/s) Response time: < 10 seconds (from 10 to 80% RH, Vair = 2 m/s) Ambient model: from -20 to +80 °C Remote model with polycarbonate probe: from -20 to +80 °C Remote model with stainless steel probe: from -40 to +180 °C Pt100 temperature Response time: T90 = 0.9 second for Vair = 1 m/s Class 210 transmitters have two analogue outputs which correspond to both displayed parameters. It is possible to activate one or two outputs and to select for each between humidity, temperature and the calculated parameters (the default configuration for the output 1 is 0-100% RH and 0-50 °C for the output 2). Available only with the remote probe / (2)Calculated value / (3)All the accuracy indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or ca

Open the catalog to page 1
TH 210-R - 2

General features TH 210-BXX models: 24 Vac/Vdc ±10% TH 210-HXX models: 100-240 Vac, 50-60 Hz Power supply Warning: risk of electric shock 75 x 40 mm, LCD 20 digits 2 lines. Height of digits: Values: 10 mm; Units: 5 mm 2 x 4-20 mA or 2 x 0-20 mA or 2 x 0-5 V or 2 x 0-10 V (4 wires) Common mode voltage < 30 VAC Maximum load: 500 Ω (0/4-20 mA) Minimum load: 10 kΩ (0-5/10 V) Cable gland Relay outputs Inputs and outputs (models 100-240 Vac) Device fully protected by Galvanic isolation DOUBLE ISOLATION or REINFORCED ISOLATION Outputs (models 24 Vac/Vdc) Screw terminal block for cable 2.5 mm²...

Open the catalog to page 2
TH 210-R - 3

0-5/10 V – Tension GND – Masse 0/4-20 mA – Courant 0-5/10 V – Tension GND – Masse 0/4-20 mA – Courant Terre fonctionnelle Neutre (N)~ Phase (L)~ COM : commun Relais 1 et 2 For your safety and in order to avoid any damage of the device, please follow the procedure NC : normalement fermé described in this document and read carefully the notes preceded by the following symbol: *Fusible uniquement présent sur les modèles 100-240 Vac. Tout changement de fusible doit The following symbol will also be used in this document,être réalisé appareil hors tension en utilisant information 250 V. please...

Open the catalog to page 3
TH 210-R - 4

Transmitters configuration It is possible on the class 210 to configure all the parameters of the transmitter: units, measuring ranges, outputs, channels, calculation functions, etc. via different methods: • Keypad for models with display: a code-locking system allows to secure the installation (See class 210 transmitters user manual). • Software (optional) on all models. Simple user-friendly configuration. See LCC-S user manual. 0 Caution: the minimum difference between the high range and the low range is 20. Configure the range according to your needs: outputs are automatically adjusted...

Open the catalog to page 4