Open the catalog to page 1Rotor type Heat recovery member of CAREL group ltatatawawatA/r Vtatatawatatataiw rA^AVATATATATA^TArU UnffiMfUK0ilRSns0W| ATATATATAWATiS'AUt only sensible, latent only at Condensation Systems with no humidification and no cooling limited latent Systems with humidification and without cooling (within the whole seasonal cycle) Systems with humidification and cooling, reduction of cooling capacity by drying and cooling the external air only sensible, latent only at Condensation Systems with high exhaust air requirements such as: - swimming pools - industrial exhaust systems - Adiabatic humidification...
Open the catalog to page 2Rotor range overview Housing versions member of CAREL group RRU ECO RRS RRT RRV All housing versions are available with the storage masses P-condensation, E-enthalpy (hybrid), N-sorption and K-epoxy coated available Housing material Execution Max. housing size (HS) Cladding sheets Galvanized steel screwed Undivided housing version up to 2550 mm (0 2500) mm Divided housing version up to not possible Galvanized steel welded 400 mm to 2000 mm housing size 440 mm to 3000 mm housing size 550 mm to 4250 mm housing size Installation position Inspection of drive on narrow side Inspection through triangular...
Open the catalog to page 3member of CAREL group Sensible for ventilation and air conditioning systems with high exhaust air loads. Cleaning of the storage medium surface with compressed air and/or high-pressure water. Note media provision (compressors and HP modules) and the necessary piping! The cleaning equipment also has to be cleaned (particularly for wet cleaning) Reinforced media of at least 0.1mm foil thickness recommended for high-pressure cleaning. Compressed Air and pressure water cleaning Exhaust Air
Open the catalog to page 4Sealing Systems Reduction of leakage at rotor circumference and water line separation. There are two types of seals: airflow separation ( ) Rotor circumference ( ). member of CAREL group Special plastic seal (spring-loaded) for paint booths and Brush seal for airflow separation ( ) systems with very high sealing requirements ( ) standard ventilation and air-conditioning Pressure-stable felt seal for standard ventilation and air-conditioning ( ) Rotor circumference brush seal ( ) standard ventilation and air-conditioning
Open the catalog to page 5Installation position - vertical with horizontal or vertical air flow separation member of CAREL group As a general rule, no transfer of external power in the rotor frame - No additional construction required - horizontal installation - Framed support of rotor and bearing area required - horizontal inclined installation - Base frame construction and brake motor and/or control system with holding torque and guide plates recommended Odour transfer Depending on the direction of leakage (fan arrangements) and Kitchen smells; water-soluble, bathroom smells ;non-water-soluble, use of sorption water...
Open the catalog to page 6Rotor controller Control of the speed of the rotor and thus the recovery performance. Drive variant with stepper motors Stepper motor with control unit for variable or constant speed Drive variant with stepper motors Drive variant with geared motors Three-phase 50 Hz motors are optionally available for constant drive or for operation with a frequency converter, designed with worm gears Various sizes are available for both systems Drive variant with geared motors Controller operation with on-site control signal or as individual control with sensors. Controller can be specified in the LV MSR, retrofitting...
Open the catalog to page 7member of CAREL group Self-Cleaning Counter-current air flow cleans dry contamination from storage masses. Requirement: rotating rotor and/or activated intermittent operation. Software terminology Standard volume Air volume relative to 20°C / 50% relative humidity / 1013 mbar Operating volume Air volume for given temperatures and relative humidities Flow rate Air speed in relation rotor to effective surface, not cross section of duct Pressure loss standard density relates to standard volume Purge sector Avoidance of cross contamination between return and supply air due to rotation. Respect purge...
Open the catalog to page 8member of CAREL group Purge sector dimensions depend on the pressure difference between the through flows Purge sector: yes Leakage: « 3-5% Purge sector : yes / may be reduced in size Leakage: Leakage higher than 10% in direction of supply air Sealing: Double center line Leakage: Leakage higher than 10% in direction of exhaust air Sealing: then double seals on middle horizontal frame. Water-tight collection chamber Inclined aluminium tray in rotor housing with drainage at the lowest position for efficient draining of conden- with condensate drain sate and cleaning fluid. Required for rotors with...
Open the catalog to page 9Glossary Leakage and Purge Sector Calculation OACF: (Outdoor Air Correction Factor) Outdoor Air Volume/Supply Air Volume (possibly < 1) Classification number for increased power of ODA/SUP-fan. Consists of leakage caused by sealing gaps and purge air, if applicable. EATR: (Exhaust Air Transfer Ratio) E xtract Air Volume in Supply Air/Supply Air Volume (>0) Classification number for the amount of extract air transferred into the supply air. Under ideal circumstances (use of an effective purge sector) this value can be reduced to nearly 0%. Consists of air transferred due to rotation 4 and leakage...
Open the catalog to page 10Product Desciption Example: member of CAREL group Type of rotor Thickness Enthalpy rotor Sorption rotor HUgo Epoxy coated rotor
Open the catalog to page 11Ki KLIIMGEIMBURG member of CAREL group Klingenburg GmbH Brusseler Str. 77, 45968 Gladbeck, Germany