1 Frame type 5a Frame height [mm] 8 Installing position RRU (ECO) 2 Storage mass type 13 Drive sytem 14 Wiring P: condensation E: enthalpy K: epoxy coated N: sorption 7 Division 3 Foil thickness B: 0.10 mm C: 0.08 mm Number of segments Storage mass 2nd number: Number of housing parts E#/#A = divided, assembled at the factory E#/#B = divided, not pre-assembled Options A, B only, if not standard Standard for up to 2 housing parts: pre-assembled Standard for up to 3 housing parts: not pre-assembled Code could be longer in the case of a 12-segments division on the storage mass - E8/2 Storage mass with 8 segments, Housing divided into 2 parts - E12/2 Storage mass with 12 segments - E24/2 Storage mass with 12 segments with one attachment package each - E36/2 Storage mass with 12 segments with 2 attachment packages each PN: none PS: small (5°) PL: large (10°) 10 Cladding sheets S0: none S1: with 11 Revision door R0: none R1: side door R3: triangular door (on motor) on both sides R4: triangular door (motor and controller) on both sides RZ: customized 12 Condensate tray Klingenburg Produktcode 0925 de en T1: tray (aluminium), flush T2: tray (V2A), flush T4: tray (V2A), flush T11: 1 + 150 mm drain pipe T21: 2 + 150 mm drain pipe T41: 4 + 150 mm drain pipe TZ: customized Standard thread sizes: DGC: Gear motor 230/400V without controller DGV: Gear motor 230/400V with MICROMAX controller + DGW: Gear motor 230/400V without MICROMAX controller and without RC DSC: Stepmotor 230V constant with OJ controller DSV: Stepmotor 230V variable with OJ controller DSR: Stepmotor 230V variable with OJ controller and RC DGR: Gear motor 230/400V without controller, with RC DGO: Gear motor 230/400V variable with OJ AC controller + RC DKC: Gear motor UL 230/460V constant without controller DLC: Gear motor UL 575V constant without controller DMC: Gear motor UL 208V constant without controller DKO: Gear motor UL 230/460V variable with OJ AC controller + RC DLO: Gear motor UL 575V variable with OJ AC controller + RC DMO: Gear motor UL 208V variable with OJ AC controller + RC DKR: Gear motor UL 230/460V without controller + RC DLR: Gear motor UL 575V without controller + RC DMR: Gear motor UL 208V without controller + RC DZZ: customized Standard settings: For gear motor without controller: VBP for 50 Hz For gear motor variable: VBP for 80 Hz For UL gear motor without controller: VBP for 60 Hz For step motor: The connection voltage does not affect the For gear motor constant: Star connection For gear motor variable: Delta connection A fourth or fifth digit may be added to the code if the standard differs from: A: VBP for 50 Hz B: VBP for 80 Hz C: VBP for 60 Hz E: Star connection F: Delta connection Example: DGCBF = Gear motor without controller, wired in delta connection and VBP for 80 Hz, as controller is provided by customer RC= rotor running control VBP = V-belt pulley C10: Defined as: Motor pre-wired to controller; requirement: Controller installed (narrow side above motor) CP0: (Gear) motor pre-wired, without controller CL0: Motor pre-wired, controller packaged separately (stepper motor always with connecting cable) C0G: As C00, but with openings (3x) for cable glands (PGs) (included, near motor), covered with plastic caps, all corners, both sides C1G: C10 + openings (3x) for cable glands (PGs) (included, near motor), covered with plastic caps, all corners, on both sides CPG: CP0 + openings (3x) for cable glands (PGs) (included, near motor), covered with plastic caps, all corners, both sides CLG: CL0 + openings (3x) for cable glands (PGs) (included, near motor), covered with plastic caps, all corners, on both sides A customised variant must be added for customised inspection doors (RZ), drives (DZZ) or cabling (CZZ). 15 Cleaning device J1: RCD (Rotor cleaning Device = single-sided cleaning, Gladbeck) This -JX code is optional. The code -JX only indicates whether and what type of cleaning is added to the rotor The cleaning itself is considered a separate component with detailed code. 16 Customised version (optional) ??? Three capital letters as customer code ## Two-digit number for different variants of the same product code with detailed code.
Open the catalog to page 123 Pages
4 Pages
13 Pages
11 Pages