Crop Ventilation Systems Efficient Ventilation for Grain Storage
Open the catalog to page 1Why Safe Storage Matters When grain is harvested, securing safe storage is the next priority. Regardless of the conditions under which the grain is harvested, it is an organic material that contains moisture, making it vulnerable to mould growth, fungal contamination, and insect infestation if not stored properly. It is all about maintaining the right moisture levels, temperature, and aeration of the stored grain. A well-constructed and well-operated storage solution is essential to ensure safe storage that meets food safety standards while avoiding quality losses and financial consequences....
Open the catalog to page 2On-Floor Systems with Lateral Ducts A common and cost-effective method of supplying air to grain storage is by using lateral ducts; these semi-circular ducts are positioned on the floor, above floor level. Kongskilde’s lateral ducts ensure optimal air distribution, making them ideal for all crop types, including small seeds. With varied sizes and tapered design options, the ducts can be combined to suit any drying or aeration setup, providing a highly customizable solution for grain storage and drying facilities. This solution is especially effective for integration into existing flat storage...
Open the catalog to page 3Lateral Duct Selection Lateral Ducts A complete range of lateral ducts and accessories is available for efficient on-floor drying and storage. Offered in multiple sizes, the ducts ensure optimal airflow and even air distribution throughout the entire system. Various perforation options make them suitable for nearly all grain types, including rapeseed and other small seeds, and the range also includes specialized lateral ducts for potatoes and onions. Type KMP P are fully perforated with 010 mm holes and ideal for potatoes and onions Galvanised design Free cross-section approx. 6.5%
Open the catalog to page 4Lateral Ducts for Grain, Rape, and other Seeds For bulk and free-flowing grain and seeds Galvanised design Effective duct length 850 mm Free cross-section approx. 28% Maximum storage height for grain approx. 15 m Air volume/h at 10 m/sec for P 900 = 3,200 m3/h Air volume/h at 10 m/sec for P 1600 = 5,700 m3/h KMP lateral ducts are fully perforated with 02 mm holes KMP T lateral ducts are with closed top and only perforated along the sides. KMG lateral ducts with closed top and vent louvres along the sides.
Open the catalog to page 5Aeration Accessories Various accessories are available for all listed lateral duct sizes. 9382105540 KMP 900-KMP 1600 reduction adapter for lateral duct, galvanised 9382105541 KMP 2500-KMP 1600 reduction adapter for lateral duct, galvanised 9382105542 KM 3500-KMP 2500 reduction adapter for lateral duct, galvanised KMP 900 end plate for lateral duct, galvanised KMP 1600 end plate for lateral duct, galvanised KMP 2500 end plate for lateral duct, galvanised Connections for wooden walls incl. shutter (not illustrated) 9382105550 KMLT 900 connection for lateral duct on wood, incl. shutter, length...
Open the catalog to page 6T-distributor for KMP 900 lateral duct, galvanised T-distributor for KMP 900 on KMP 1600 lateral duct, galvanised T-distributor for KMP 1600 on KMP 2500 lateral duct, galvanised Y-connection pieces 9382105509 Y-distributor for KMP 900 lateral duct, galvanised 9382105510 Y-distributor for KMP 1600 lateral duct, galvanised 9382105511 Y-distributor for KMP 2500 lateral duct, galvanised Cross connection pieces for 4-ways intersections 9382105515 X-distributor for KMP 900 lateral duct, galvanised 9382105516 X-distributor for KMP 900 on KMP 1600 lateral duct, galvanised 9382105517 X-distributor for...
Open the catalog to page 7Underfloor Aeration Systems Drive-over Ventilation Grates Drive-Over Grates & Underfloor Shuttering An on-floor drying and storage solution with underfloor aeration channels and perforated drive-over grates provides a fully unobstructed floor area, allowing easy access for lorries and other traffic. The channels are formed using shuttering boxes, also referred to as steel troughs or formers. Once the channel system is positioned and embedded in the concrete floor, the drive-over grates are installed in the shuttering, functioning as below-floor laterals. For bulk and free-flowing grain and seeds...
Open the catalog to page 8Shuttering Boxes for Drive-Over Grates Threaded bars M6x500 mm: 1 each m channel 2 each panel 2 each angle piece 4 each T-piece With nut, 6 each channel T-piece, 6 each channel End sheet, 4 each Angle piece, 6 each Facet washer/8mm, 1 each carriage bolt All shuttering boxes and accessory parts are made of When ordering shuttering these are supplied with the galvanised steel and can be used for both KMP and necessary fitting for easy assembly. KMSP travel grates. The 2 different heights can be combined as can all the different connection pieces and accessories.
Open the catalog to page 9Angle pieces, galvanised T-pieces, galvanised Channel connections, galvanised Reduction plate for connecting shutering boxes of height 473 and 350 mm, galvanised
Open the catalog to page 10Teyfun Point Aerator Teyfun Point Aerator The Teyfun Point Aerator is designed for aeration and limited drying of grain and seed crops. It is a flexible tool that can supplement on-floor drying systems in flat storage or for temporary grain stacks where no aeration system is installed. Portable and easy to relocate, the Teyfun can blow cool ambient air into the grain to improve ventilation or use its suction function to extract warm air, remove heat pockets, and help prevent combustion risks. • Available in two models: KM 15 with 1.5 kW motor and KM 22 with 2.2 kW motor Galvanised perforated...
Open the catalog to page 11Backwards curved rotor blades ensure high airflow and optimal efficiency. Rain cover for outdoor installation available as optional. Kongskilde offers a wide range of high-volume lowpressure blowers ideal for drying and aeration of grain and other crops. Suitable for different applications The air flow rate of this type of blower varies little with changes in the air pressure resistance, caused by the different types of crops in on-floor-storages, silos or driers. The HVLs are therefore an ideal solution, also for smallseed crops like rape seed having a higher resistance to the air flow. Owing...