1. Catalogs
  2. Lykketronic A/S
  3. Standard hall sensors

Standard hall sensors

Standard hall sensors

Product catalog summary
Overview
These sensors are primarily used in applications with frequent activations, such as measuring the RPM of motors. They are commonly used with Lykketronic monitors and computers but not typically with Flex Counters.
Technical Specifications
  • Hall Sensors: Based on magnets, available in two versions: rectangular and cylindrical.
  • Rectangular Version:
    • Dimensions: 23 x 30 x 16 mm
    • Connection: Cable
    • Range: 3 – 8 mm with magnets
    • I/O Function: NO
    • Max Load: 25 mA
    • Resistance: 100 ohm
    • Power Supply: 12 V DC
  • Cylindrical Version:
    • Dimensions: Ø 12 x 45 mm
    • Connection: Cable
    • Range: 3 – 8 mm with magnets
    • I/O Function: NO
    • Max Load: 25 mA
    • Resistance: 100 ohm
    • Power Supply: 12 V DC
Ordering Information
  • Rectangular Sensors:
    • 110-1-7001: 7 m sensor without plug
  • Cylindrical Sensors:
    • 110-1-5000: 5 m sensor Ø12 mm without plug
    • 110-1-9099: 10 m sensor Ø12 mm without plug
Accessories
  • 000-1-0003: Installation kit with screws and nuts
  • 000-1-0012: Installation kit with screw, nut, magnet, and sealing disc
  • 110-8-2000: Magnet
Installation
The sensor is mounted near the tractor or equipment wheel, with the corresponding magnet mounted on the rotating shaft. Sensors can be delivered in requested cable lengths.
Guarantee
1-year guarantee from the date of delivery.
Contact Information
Lykketronic A/S, Stengaardsvej 20, DK-9670 Løgstør, Denmark. Telephone: +45 9868 3019, Fax: +45 9868 3216, Email: [email protected], Website: www.lykketronic.dk
See more

Catalog excerpts

Standard hall sensors-1

(Product sheet Hall sensors - 0711) 0 12 x 45 mm Cable 3 - 8 mm with magnets NO 25 mA 100 ohm 12 V DC 1 year guarantee from date of delivery. Use These sensors are typically applied where many activations occur, e.g. by measurement of rpm on motors. Among other things these sensors are used in connection with Lykketronic monitors and computers, however normally not in connection with Flex Counters. Technical specifications Hall sensors are based on magnets and are delivered in two versions. Rectangular Dimensions: Connection: Range: I/O function: Max load: Resistance: Power supply: Cylindrical Dimensions: Connection: Range: I/O function: Max load: Resistance: Power supply: 110-1-7001 7 m sensor without plug Sensor accessories: 000-1-0003 Installation kit: screws (2 pcs.) and nuts (2 pcs.) 000-1-0012 Installation kit: screw, nut, magnet Sensor accessories: 000-1-0012 Installation kit: screw, nut, magnet Installation The sensor is mounted nearby the tractor or equipment wheel. The corresponding magnet is mounted on the rotating shaft. Sensors can be delivered in cable lengths as requested. Guarantee Lykketronic A/S • Stengaardsvej 20 • DK-9670 Logstor, Denmark • Telephone: +45 9868 3019 • Fax: +45 9868 3216 • [email protected] • www.lykketronic.dk

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.