Introduction
The document provides instructions for the GLM Kit, a grain losses monitoring system for combine harvesters, including sieve, straw walker, and recovery sensors. It is intended for manufacturers and ensures compliance with EMC standards.
Warranty Terms
The GLM Kit and its accessories are covered by a one-year warranty from the date of manufacture, excluding accidental damage, improper use, unauthorized changes, and damage from external equipment or force majeure. Warranty repairs must be conducted at authorized centers.
General Description
The GLM Kit enhances combine harvester performance by monitoring grain losses through sensors, providing feedback via a graphical interface with histograms and buzzers to alert operators when losses exceed thresholds.
System Installation
Installation involves setting up a Virtual Terminal and sensors, which include proximity inductive and capacitive types, with specific spacing and positioning guidelines.
Keyboard Operation
The system features a home screen for software versions and a main screen for operational data, allowing users to navigate menus to adjust settings and calibrate sensors.
Graphic Interface Description
The interface allows configuration of language, units, date and time, backlight, buzzer volume, and automatic dimming, with software updates managed through the interface.
Work Screen
Displays work speed, fan RPM, destemmer paddle RPM, and average hectares worked per hour, allowing adjustment of multiplicative factors for sensor calculations.
Sensor Sensitivity Screen
Users can calibrate the sensitivity of recovery, straw walker, and sieves sensors for accurate grain loss monitoring.
Programming
Access to user settings is available through the main screen, allowing customization of system parameters to suit operational needs.
Overview
The document provides detailed instructions for the use and configuration of the GLM KIT, including machine settings, user settings, diagnostics, programmable parameters, software updates, and technical data.
1. Machine Settings
Access is password-protected, allowing users to adjust system parameters to match the specific machine, including sieves constant, straw walker constant, and return constant.
2. User Settings
Users can configure working mode, set pulses per revolution for sensors, calibrate the speed sensor, and adjust working width for loss calculations.
3. Diagnostics
The diagnostics menu allows operators to check the ECU software version and voltage of the GLM control unit.
4. Programmable Parameters
Lists adjustable parameters such as work width, sensitivity settings, and calibration values for sensors.
5. Software Updates
Instructions for updating the Virtual Terminal and ECU software using an SD card, with specific file types and card formats required.
6. Technical Data
Technical specifications for the 3.5” Virtual Terminal, ECU GLM, and sensors, including power supply voltage, operating temperature, and protection ratings.
7. Accessories
Information on sensors, including power requirements and operational characteristics.
Important Note
Users are cautioned against using power washers with pressure jets on the equipment.
See more

Catalog excerpts

GLM KIT-1

GLM KIT GRAIN LOSSES MONITOR MONITORING SYSTEM FOR COMBINE HARVESTERS (sieve sensors + straw walker sensors + recovery sensors) INSTRUCTIONS FOR USE O.E.M. VERSION (MANUFACTURERS) NO. 1713-GLM OEM-EN REV. 3

 Open the catalog to page 1
GLM KIT-2

This product meets the EMC standards as determined in the 2004/108/EC directive and subsequent amendments and reference to the applied EN ISO 14982 standard Fiesso Umbertiano (ROVIGO) - ITALY Tel. +39 0425 754713 Fax +39 0425 741130 E-mail: [email protected] Internet: www.mcelettronica.it Manual code Issued Edition MC Elettronica S.r.l. is not obliged to give notice of any further modifications of the product. The information given in this manual does not allow unauthorised personnel to tamper with the product in any way. The warranty on the equipment will no longer be valid if tampering...

 Open the catalog to page 2
GLM KIT-4

1. Rules and general warnings 1.1 Introduction This instruction manual provides all specific information needed to know and correctly use the equipment. After buying the Monitor, read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations. Keep the manual on the machine. If this is not possible, keep it ready at hand. ALL RIGHTS RESERVED. THIS MANUAL IS INTENDED FOR CUSTOMERS ONLY. ANY OTHER USE IS FORBIDDEN.

 Open the catalog to page 4
GLM KIT-5

SUBJECT OF THE WARRANTY: the warranty is applied to the product and to those parts which are marked with the serial number or any other identification number used by MC elettronica; DURATION OF THE WARRANTY: MC elettronica guarantees the GLM KIT and its accessories for a period of 1 year from the date of manufacture (printed on the identification label on the back of the Monitor). The warranty covers the product and any repairs carried out within the agreed terms. This warranty does not apply in the event of: • accidental damage; • improper use; • changes which have not been agreed upon, improper...

 Open the catalog to page 5
GLM KIT-6

2. General description GLM kit is a system that allows to increase the performance of the combine harvester (in ha/h) installing sensors in the sieves and straw walker. It is also possible to add an optional sensor inside the recovery channel in order to allow the operator to adjust the sieves with precision. By means of a graphical interface with histograms and buzzer it will inform the operator when losses exceed the set loss threshold in order to achieve maximum operation speed. The system only operates with the ECU GLM control unit: CALIBRATE THE LOSS SENSORS PRIOR TO USE: 1) WITH THE MACHINE...

 Open the catalog to page 6
GLM KIT-7

Figure 2 - 3.5” Virtual Terminal dimensions 40MON-0001

 Open the catalog to page 7
GLM KIT-8

Figure 3 - ECU GLM dimensions code 40CEN-0001

 Open the catalog to page 8
GLM KIT-9

3.1 Virtual Terminal assembly To assemble the Virtual Terminal, proceed as follows: • Screw the suction bracket onto the rear part of the Virtual Terminal using the supplied screws • Fasten the suction bracket onto a clean flat surface. Otherwise, the Virtual Terminal can detach itself and fall during operations Note: we recommend installing the Virtual Terminal in front of the operator to make it easier to use during the work cycle. Figure 4 - 3.5” Virtual Terminal assembly

 Open the catalog to page 9
GLM KIT-10

3.2 Sensor installation The GLM KIT can be fitted with the following types of sensor: • • Proximity inductive sensor, NPN, 12V, N.A. Capacitive sensor, NPN, 12V, N.A. 3.2.1 Speed sensor installation You can install the speed sensor anywhere there is mechanical movement, on the wheel (front or rear wheel) of the agricultural vehicle/machine or applying a metal reference protruding by at least 7 mm (Figure 5- ref. ). Adjust the distance between the sensor and the bolts to 2-3 mm (Figure 5 – ref. ). Fasten the sensor supporting bracket (supplied) securely to a fixed part of the vehicle structure....

 Open the catalog to page 10
GLM KIT-11

3.2.2 "RPM" sensor installation The inductive sensor to detect turbine RPM must be positioned in front of metal references with a diameter at least equal to the corresponding sensor and protruding from any other metal mass by at least 7mm. The distance between the sensor and its metal reference varies from 2 to 3mm. The figures below show two different installation examples. 2-3 mm RPM sensor RPM sensor Bushing PTO connection Bolt Bolt Figure 6 - Installation of the inductive sensor D.18 on the PTO. 2mm Figure 7 - Installation of the inductive sensor D.12 on the gearbox. Warning The sensor cable...

 Open the catalog to page 11
GLM KIT-12

3.3 Keyboard operation 3.3.1 Home screen Figure 8 When switched on during the initial phase, the following screen appears, showing the software version of the Virtual Terminal. 1. 2. VT SET: pressing the menu key when the system is starting up displays the Virtual Terminal management menu. ON/OFF: system switch-on and switch-off.

 Open the catalog to page 12
GLM KIT-13

Figure 9 The front panel allows the operator to display all the data of the working cycle. The following elements can be seen on the panel: 1. 2. 3. 4. ON/OFF: system switch-on and switch-off. Menu: press it once to go to the next screen; press and hold down to switch to the programming mode. UP: increases the selected value. DOWN: decreases the selected value. OK : selects the parameter to be changed

 Open the catalog to page 13
GLM KIT-14

3.3.3 Screen of sensor sensitivity ON/OFF: system switch-on and switch-off. Menu: press it once to go to the next screen; press and hold down to switch to the programming mode. UP: increases the selected value. DOWN: decreases the selected value. OK : selects the parameter to be changed

 Open the catalog to page 14
GLM KIT-15

3.4 Graphic interface description 3.4.1 Home screen Pressing the menu key during system startup allows access to the device configuration screens. VT SET consists of the following parameters: 1. Language: system operation language selection 2. Unit of measurement: selection of the type of unit of measurement to use. 3. Date and time: set date and hour of the system. 4. Backlight: display backlighting intensity adjustment 5. Buzzer volume: buzzer volume adjustment. 6. Dimmer: automatic "day" to "night" switching mode can be scheduled and vice versa, the two modes are designed to optimise visibility...

 Open the catalog to page 15