1. Catalogs
  2. MC Elettronica srl
  3. KIT HYDRA 590 and CB9
video corpo

KIT HYDRA 590 and CB9

KIT HYDRA 590 and CB9
1 / 40 PagesView full catalog

KIT HYDRA 590 and CB9

Product catalog summary
Introduction
The manual provides comprehensive instructions for the KIT HYDRA 590 and CB9, emphasizing the importance of thorough reading to ensure proper use and maintenance. Unauthorized tampering voids the warranty.
Compliance and Manufacturer Information
The product complies with EMC requirements under Directives 2004/108/EC and is manufactured by MC Elettronica S.r.l., Italy.
Terms of Guarantee
The equipment is guaranteed for one year from the manufacturing date, covering manufacturing defects but excluding accidental damage, improper use, and unauthorized modifications. Warranty repairs are free if conducted at authorized centers.
General Description
The HYDRA 590 system is designed for sprayers to manage dosing, distribution, and section valve operations, supporting up to 9 sections and integrating with GPS for automatic section control.
Installation Instructions
Detailed steps for installing the main ECU and additional modules are provided, emphasizing the importance of proper installation for system functionality.
Front View and Controls
The front panel includes controls and indicators for system operation, such as menu navigation, hydraulic function locking, and system power.
Sprayer Work Screen
The work screen displays critical information like speed, tank content, and operational mode, including the status of the air sleeve and GPS automatic closing.
Connection of Solenoid Valves
Instructions for connecting cables from the main ECU to solenoid valves ensure correct operation of the sprayer's mechanical functions.
Technical Data and Troubleshooting
Technical specifications and troubleshooting tips are included to address common issues, ensuring optimal performance of the KIT HYDRA 590 and CB9.
Bar Status Display
The document outlines the status display for bar sections, indicating inactive, active, and spraying sections.
Function Keys Overview
  • Water Functions: F1 to F6 keys control air sleeve activation, section enabling/disabling, and icon switching.
  • Oil Functions: F1 to F6 keys manage hydraulic valve operations for mechanical locks, bar adjustments, and tilting.
  • Tank Loading Functions: F1 to F6 keys set tank content levels and allow manual input of desired amounts.
Virtual Terminal Settings
The VT settings menu allows adjustments for language, units of measure, contrast, brightness, buzzer volume, automatic switch-off, and date/time.
ECU Spray Settings
The ECU settings menu includes options for dosing, air sleeve adjustments, counter management, and alarm settings for dose, speed, pressure, and tank levels.
Work Menu
This section covers pressure adjustment, automatic speed settings, dose tolerance, and product density, including options for section opening types and GPS-based automatic closing.
Nozzle and Bar Menus
The nozzle menu allows flow rate adjustments, while the bar menu calculates total width based on nozzle distance and number.
Sensor Menus
Includes calibration and diagnostics for speed, flow meter, pressure, and tank level sensors, with procedures for manual and automatic calibration.
Season Counters and Simulated Speed
Season counters can be reset individually, and simulated speed mode allows system testing while stationary.
Pressure Working Method
Describes the default flow meter method and the optional pressure method, including simulation mode for parameter adjustments.
Reserved Menu and Trailmatic Option
The reserved menu requires a password for service use only, and the Trailmatic option controls the steering shaft to align with the tractor's articulation.
Overview
The document provides detailed instructions and technical specifications for the KIT HYDRA 590 and CB9, focusing on the Trailmatic graphical interface, manual control operations, troubleshooting, and technical data.
Trailmatic Graphical Interface
Access the Trailmatic control using the F6 key function bar. Manual control keys allow for the movement of the hydraulic joint manually.
Mechanical Sensor Layout
Details on the layout of mechanical sensors are provided.
Troubleshooting
Common problems and solutions include checking battery connections, CAN-BUS cable connections, wheel sensor calibration, and flow meter connection.
Technical Data
Specifications include nominal power supply voltage, max current consumption, display details, inputs and outputs, IP protection degree, and dimensions and weight for monitor and ECU.
Disposal Warning
The product contains tin and lead and must be disposed of at designated facilities or returned to MC Elettronica SRL in Italy.
See more

Catalog excerpts

KIT HYDRA 590 and CB9-1

KIT HYDRA 590 and CB9 COMPUTER FOR SPRAYERS

 Open the catalog to page 1
KIT HYDRA 590 and CB9-2

This product complies with EMC requirements in accordance with Directives 2004/108/EC and subsequent amendments and reference to Applied Regulation EN ISO 14982 Fiesso Umbertiano (ROVIGO) - ITALY Tel. +39 0425 754713 Fax +39 0425 741130 E-mail: [email protected] Internet: www.mcelettronica.it Manual code Issued Edition MC elettronica S.r.l. is not obliged to give notice of any further modifications to the product. The Information provided in this manual does not allow unauthorised personnel to tamper with the product in any way. The guarantee on the equipment will no longer be valid if...

 Open the catalog to page 2
KIT HYDRA 590 and CB9-5

1. Rules and general warnings 1.1 Introduction This manual gives all the specific information that you need for a proper use of the equipment. After buying the instrument, read the manual carefully and refer to it any time you have doubts on how to use the equipment or when you have to carry out maintenance operations. Keep the manual on the machine. If this is not possible, keep it ready at hand. ALL RIGHTS RESERVED. THIS MANUAL IS INTENDED FOR CUSTOMERS ONLY. ANY OTHER USE IS FORBIDDEN.

 Open the catalog to page 5
KIT HYDRA 590 and CB9-6

1.2 Terms of guarantee • SUBJECT OF THE GUARANTEE: the guarantee is applied to the product and to those parts which are marked with the serial number or any other identification number used by MC elettronica; • HOW LONG THE GUARANTEE IS EFFECTIVE: MC elettronica guarantees the KIT HYDRA 590 and CB9 and its accessories for a period of |l year|from the manufacturing date (printed on the identification plate on the back of the Monitor). The guarantee covers the product and any repair carried out within the agreed terms. The guarantee does not apply in the event of: • accidental damage; • improper...

 Open the catalog to page 6
KIT HYDRA 590 and CB9-7

2. General description The HYDRA 590 system is designed to be installed on self-propelled or towed sprayers, and is used to: • • • • • Check the product dosing and automatic and manual distribution Check the opening and closing of the section valves on the machine, up to 9 sections Check the section bar movement, up to 5 usable movements Check the air sleeve speed, with 2 user programmable speeds. Connect to a GPS guidance system to automatically close sections and prescription maps (Avmap, Trimble) The computer only works with an ECU Water/Oil Hydra control unit, code 20CEN-HYDRA-0001.

 Open the catalog to page 7
KIT HYDRA 590 and CB9-8

2.1 Installation instructions with 7 sections additional module Proceed with the installation of the Kit Hydra590 / CB9 as described below: • Secure the main ECU (20CEN-HYDRA-0001) as close as possible to the water section valves in a vertical position and so that the connectors are arranged on the RH and LH as in the photo Secure the extra oil ECU (20CEN-0006 / Caffini version CFN-CEN-0001) close to the previous Main ECU in a vertical position with the connector facing downwards Secure the Hydra590 / CB9 monitor and the 7 sections oil command (20COM0001 / Caffini version CFN-COM-0001) in the...

 Open the catalog to page 8
KIT HYDRA 590 and CB9-9

• The S.Seal 4-way must be connected to the S.Seal connector left free of the CAN_BUS cable coming from the 7m monitor (CAB-0037 / Caffini version CFN-CAB-0007 x 13m or CAB-0036 / Caffini version CFN-CAB-0006 x 7m) A Warning Pay particular attention to connect this last described cable to the 7-sections additional oil ECU (20CEN-0006 / CFN-CEN-0001) • Finally, check that the SW ver 0.05 or higher is loaded in the main ECU. To check it enter the Hydra590 / CB9 menu and read the installed version at the top right of the blackened bar; if it is not present, proceed with the update Notes: Always...

 Open the catalog to page 9
KIT HYDRA 590 and CB9-10

The cable 20CAB-HYDRA570-0006 coming from the main ECU and the CAB-0038 / CFN-CAB-0001 cable coming from the 7-section ECU must be connected to the respective EV according to the table below:

 Open the catalog to page 10
KIT HYDRA 590 and CB9-11

4 Figure 1 The front panel allows the user to view all the data relating to the working cycle. The following elements can be seen on the panel: 1. 2. 3. 4. 5. 6. 7. 8. 9. Menu: To enter the programming menus and then return to the initial screen. ESC: To go back one screen in the programming menus. Lock: To lock and unlock hydraulic functions. F1-F2-F3-F4-F5-F6: Keys associated with the corresponding function shown on the display. Arrow keys: RH, LH, UP, DOWN menu navigation keys. OK: enter key. A/M: Automatic / manual dosing key. General: spraying start / stop. ON/OFF: system switch-on and switch-off....

 Open the catalog to page 11
KIT HYDRA 590 and CB9-12

3. Air sleeve: if the icon is visible, the air sleeve is on. 4. GPS automatic closing: if the icon is visible, automatic closing is active. 5. Lock: if visible, oil sections cannot be enabled. 6. Tank: Content left in the tank. 7. Various information: Nozzle being used (visible if pressure mode active), linear metres treatable with the content left, hectares treated with the content left, hourly output

 Open the catalog to page 12
KIT HYDRA 590 and CB9-14

3.3 Function keys part 1 (water) F1 F2 F3 F4 F5 F6 • F1= (function in sequence every time you press the key) air sleeve activation speed1> speed2> air sleeve switch-off. • F2= (function in sequence every time you press the key) sequentially disables sections towards the right, starting with the first active on the Lh • F3= (function in sequence every time you press the key) sequentially enables sections towards the left, starting with the first inactive on the Rh • F4= (function in sequence every time you press the key) sequentially enables sections towards the right, starting with the first...

 Open the catalog to page 14
KIT HYDRA 590 and CB9-15

3.4 Function keys part 2 (oil) F1 F2 F3 F4 F5 F6 • F1= enables or disables mechanical lock double-acting hydraulic valve (active = icon in the negative, inactive = icon in the positive). Opens via > arrow keys, and closes via < arrow keys (Fig. 4). • F2= enables or disables LH bar double-acting hydraulic valve (active = icon in the negative, inactive = icon in the positive). Opens via > arrow keys, and closes via < arrow keys. (Fig. 4). • F3= enables or disables RH bar double-acting hydraulic valve (active = icon in the negative, inactive = icon in the positive). Opens via > arrow keys, and closes...

 Open the catalog to page 15