1. Catalogs
  2. Meditech
  3. Arabidopsis Chamber MTAC60

Arabidopsis Chamber MTAC60

Arabidopsis Chamber MTAC60

Arabidopsis Chamber MTAC60

Product catalog summary
Product Overview and Applications: The Arabidopsis Chamber MTAC60 is designed to maximize growth area within a compact footprint, offering three tiers with a total of 60 ft² of growth area in a 25 ft² footprint. It is ideal for growing Arabidopsis and other short to medium height plants, featuring a flood tray for irrigation at each tier.
Lighting: The chamber uses a combination of fluorescent and incandescent lamps to provide a broad light spectrum with standard intensity at 300 micromoles/m²/s, adjustable to 500 micromoles/m²/s with a high light option. Heat from lamps is managed by the refrigeration system, and lighting is controlled in three levels.
Experiment Protection: The chamber includes programmable alarms for monitoring, with backup alarms for additional protection. It also supports integration with building management systems.
Key Product Attributes: Features include a top-mounted machine compartment for easy servicing, transparent barriers to minimize heat transfer, and CE certification. The chamber also includes horizontal airflow distribution for uniform temperature and air distribution.
Refrigeration System: The MTAC60 uses a water-cooled condensing unit with a hot-gas bypass system for continuous operation and precise temperature control. It includes pressure transducers for system monitoring.
Performance Data: The chamber operates within a temperature range of -2°C to +45°C, with specific conditions for lights on and off. It has an interior capacity of 103 ft³ and a growth height of 20 inches per shelf.
Construction and Design: The chamber is constructed with CFC-free insulation and features a reflective interior finish. It includes two reach-in doors with magnetic locks and observation windows with light-tight covers.
Optional Accessories: Options include high light intensity, humidity control, CO2 additive control, and various irrigation and refrigeration system enhancements.
Utility Requirements: The chamber requires specific electrical services and a floor drain outside its footprint. Installation services are available upon request.
See more

Catalog excerpts

Arabidopsis Chamber MTAC60-1

Arabidopsis Chamber MTAC60 Multi Tier Reach In Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.com

 Open the catalog to page 1
Arabidopsis Chamber MTAC60-2

The MTAC60 provides an unprecedented growth-area-foot print ratio. It uses a top-mounted refrigeration system that accommodates servicing from the front of the chamber, and that simplifies on-site installation. The MTAC60 offers three tiers with almost 60 ft2 of growth area in a 25 ft2 footprint. With a growth height of 21 inches above each shelf, the MTAC60 is ideally suited for Arabidopsis and other short to medium height plants. Standard on the MTAC60 is a flood tray at each tier to simplify plant irrigation. Please consult Meditech regarding specific requirements. Lighting The standard lighting...

 Open the catalog to page 2
Arabidopsis Chamber MTAC60-3

Arabidopsis Chamber MTAC60 Multi Tier Reach In 1.0 Control System: Meditech 7 inch Touch Screen Controller 2.0 Construction: (Note: All dimensions are nominal.) 2.1 Exterior Dimensions: 100”W x 35.5”D x 101”H (2540mmW x 900mmD x 2565mmH) (106”H with service cover opened) 2.2 Interior Dimensions: 97”W x 30.5”D (2465mmW x 775mmD) 2.3 Growth Area: 57ft² (5.2m²) on three shelves. 2.4 Growth Height: 20” (510mm) per shelf. 2.5 Perforated aluminum back wall, providing horizontal air flow. 2.6 Cabinet Construction: Bonded paneling using CFC-free insulation. 2.7 Exterior Finish: Blue-green enamel baked...

 Open the catalog to page 3
Arabidopsis Chamber MTAC60-4

Arabidopsis Chamber MTAC60 Multi Tier Reach In 4.4 Aspirator: Located in the machine compartment to provide a remote location for sensors for accurate controlling and recording, unaffected by lamp radiation. 5.0 Refrigeration: 5.1 Condensing Unit: Cabinet is supplied with a water-cooled hermetically sealed condensing unit with hot gas bypass system for continuous compressor operation, extended compressor life and close temperature control. Condensing unit is located in the machine compartment, and includes a 3-way water modulating valve and hand operated shut off bypass valve. Maximum pressure...

 Open the catalog to page 4
Arabidopsis Chamber MTAC60-5

UPS Uninterrupted Power Surge protection and uninterrupted power supply, on controller Supply only, for continuous operation of the controller during power interruptions, duration of the UPS is approx. 15 minutes. (Consult factory for increased duration, if required.) LIGHTING HL High Light High light intensity 500 micromoles/m2/s using fluorescent and tungsten incandescent lamps. (Note: Amperage increases, consult factory.) HUMIDITY (Based on +21°C and 50% RH ambient condition) DHS Dry Humidity Sensor Dry Electronic Sensor that directly measures and displays relative humidity...

 Open the catalog to page 5
Arabidopsis Chamber MTAC60-6

Arabidopsis Chamber MTAC60 Multi Tier Reach In Carbon Dioxide Additive Control CO2 Carbon Dioxide Package includes gas analyzer, control valve, and injection system. Additive Control CO2 tank not included. Irrigation System Automatic control of irrigation system through the control system. System requires a dedicated supply of irrigation water. Growth Height Two-tier chamber design increases growth height to 35” (890mm), exterior height becomes 106”H (2690mmH) (111” (2820mmH with service cover opened). Additional Operator’s Manual. (One supplied with basic unit.) Remote Outdoor Air-Cooled Condenser...

 Open the catalog to page 6
Arabidopsis Chamber MTAC60-7

sis Chamber MTAC60i Tier Reach In STANDARD REFRIGERATION SYSTEM IS WATER COOLED, (1/2”0 (13mm0) CONNECTION). 2. CHAMBER MUST BE SECURELY FASTENED TO FLOOR. 3. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH OR HINGES. 4. FOR BACK TO BACK INSTALLATION, ALLOW 2” (50mm) SPACE BETWEEN CHAMBERS. 5. LENGTH AND WIDTH DIMENSIONS ±1/4” (6mm), HEIGHT DIMENSION ±1” (25mm). DO NOT SCALE DRAWING. CONTROL PANEL — ELECTRICAL CONNECTION TOP VIEW DOOR OPENING

 Open the catalog to page 7

All Meditech catalogs and technical brochures

  1. cold room

    10  Pages

  2. co2 incubator

    15  Pages

  3. BOD Incubator

    10  Pages

  4. Incubator

    2  Pages

  5. Spirometer

    1  Page

  6. MTCR 60

    6  Pages

  7. MTCR 120

    6  Pages

  8. MTCR 180

    6  Pages

  9. MTPS432

    5  Pages

  10. MTPS360

    5  Pages

  11. MTPS288

    5  Pages

  12. MTPS216

    5  Pages

  13. MTPS144

    5  Pages

  14. MTPS72

    5  Pages

  15. MBDW120

    11  Pages

  16. MBDW80

    11  Pages

  17. MBDW40

    11  Pages

  18. MPGC20

    7  Pages

  19. MTR30

    3  Pages

  20. MTR26

    3  Pages

  21. ME7-2

    3  Pages

  22. ME8

    8  Pages

  23. MTAC26

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.