Catalog excerpts
Plant Growth Room MBDW Walk In Room Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: info@newmeditech.com. Website: www.newmeditech.com
Open the catalog to page 1Plant Growth Room MBDW Walk In Room Product Overview/Applications The MBDW series walk-in chamber is based on a modular platform available in increments of 40ft2 (3.7m2). These units offer a precise chamber environment typical of research involving C4 high-light plants grown to maturity. Unique is the top-down airflow pattern which ensures consistent plant canopy temperatures throughout the chamber. Spectral aluminum on the interior walls produces unparalleled light uniformity, while the discreet lamp loft area uses a separate cooling system to mitigate heat produced by the lighting system....
Open the catalog to page 2Plant Growth Room MBDW Walk In Room 7” Meditech touch screen controller MBDW40 2.0 Construction:(Note: All dimensions are nominal.) 2.1 Exterior Dimensions: 10’0”W x 5’10”D x 9’6.25”H (3050mmW x 1780mmD x 2900mmH) 2.2 Interior Dimensions: 7’9”W x 5’2”D x 7’11”H (2360mmW x 1575mmD x 2415mmH) 2.3 Growth Area: 40.0ft² (3.7m²) 2.4 Growth Capacity: 316ft³ (8,920 liters) 2.5 Growth Height: 95” (2415mm) from floor to underside of barrier. 2.6 Exterior Finish: White enamel baked on stucco 26ga. galvanized steel. 2.7 Interior Finish: White enamel baked on smooth 24ga. galvanized steel with specular...
Open the catalog to page 3Plant Growth Room MBDW Walk In Room 4.4 Temperature Safety Limits: Primary: A programmable min and max temperature limit alarm or a limit tracking alarm that automatically follows the programmed set point. Secondary: An independent factory-set high and low temperature limit is also provided for increased assurance. An audible alarm is standard for both limits. Activation of temperature safety limit set points turns off power to the chamber. 4.5 All components utilized for temperature control such as heaters and proportional valve are energized and deenergized by solid state devices. No...
Open the catalog to page 4Plant Growth Room Walk In Room UPS Uninterrupted Power Supply Surge protection and uninterrupted power supply, on controller only, for continuous operation of the controller during power interruptions, duration of the UPS is approx. 15 minutes. (Consult factory for increased duration, if required.) High Intensity Discharge Lighting High intensity discharge lighting using 400 watt metal halide and 400 watt high pressure sodium lamps with a light intensity of 1100 micromoles/m2/s at a distance of 1 meter from the barrier. Upon start-up, lamps experience a 5 to 10 minute warm up period before...
Open the catalog to page 5Growth Height Extension Reduced growth height by 12” (305mm). Exterior height becomes 8’6.25”H (2600mm). Growth Height Extension Extended growth height by an additional 17" (430mm). Exterior height becomes 10’11.25"H (3335mm). Growth Height Extension Extended growth height by an additional 48" (406mm). Exterior height becomes 13’6.25"H (4120mm). Right-Hand Control Panel Right-hand control compartment gives you the convenience and flexibility to arrange your chambers in a compact orderly fashion, back to back and end to end, or to facilitate its location in any appropriate space. Hose...
Open the catalog to page 6Remote outdoor air-cooled condenser complete with all weather housing, low ambient operation controls and low noise level operation. Remote location (up to 50’ [15m] combined horizontal and vertical distance) of condenser only - compressor, receiver and other refrigeration components remain in cabinet machine compartment. Order “RACH" for climates with ambient temperatures from +35°C to +45°C for extended periods. Electrical: 60Hz - 2O8-23O-10-6OHz-3 wire plus ground, 50Hz - 22O-10-5OHz-2 wire plus ground. Consult factory for either amperages or other voltages available. Notes: 1....
Open the catalog to page 7Plant Growth Room MBDW Walk In Room FOLLOWING ARE THE DIFFERENCES BETWEEN THE “MBDW SERIES” CHAMBERS MBDW80 2.1 Exterior Dimensions: 10’0”W x 11’1.25”D x 9’6.25”H (3050mmW x 3385mmD x 2900mmH) 2.2 Interior Dimensions: 7’9”W x 10’5”D x 7’11”H (2360mmW x 3180mmD x 2410mmH) 2.3 Growth Area: 80.9ft2 (7.5m2) 2.4 Growth Capacity: 640ft³ (18,075 liters) 6.2 Fresh Air: Filtered inlet 100 cfm (48 liters/second). MBDW120 2.1 Exterior Dimensions: Cabinet - 10’0”W x 16’4.5”D x 9’6.25”H (3050mmW x 4991mmD x 2900mmH) 2.2 Interior Dimensions: 7’9”W x 15’8”D x 7’11”H (2360mmW x 4790mmD x 2410mmH) 2.3...
Open the catalog to page 8Plant Growth Room MBDW Walk In Room MBDW40 PLANT GROWTH CHAMBER NOTES: 1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4"Ø (19mmØ) CONNECTION). 2. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 3. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1" (25mm). Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: info@newmeditech.com. Website: www.newmeditech.co
Open the catalog to page 9Plant Growth Room MBDW Walk In Room BDW80 PLANT GROWTH CHAMBER NOTES: 1. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4"Ø (19mmØ) CONNECTION). 2. CONDENSING UNIT REQUIRES SEPERATE ELECTRICAL SERVICE (60HZ APPLICATION ONLY). 3. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 4. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1" (25mm). Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: info@newmeditech.com. Website: www.newmeditech.co
Open the catalog to page 101. STANDARD REFRIGERATION SYSTEM IS WATER COOLED (3/4”0 (19mm0) CONNECTION). 2. CONDENSING UNIT REQUIRES SEPERATE ELECTRICAL SERVICE (60HZ APPLICATION ONLY). 3. DEPTH DIMENSION IS CHAMBER SIZE ONLY. DIMENSION DOES NOT INCLUDE DOOR LATCH. 4. LENGTH AND WIDTH DIMENSIONS ±1/4 (6mm). HEIGHT DIMENSION ±1” (25mm). CONDENSING UNIT BARRIERED LAMP LOFT -LAMP LOFT COOLING COIL CONTROL PANEL SECTIONAL LAMP BARRIER (HINGED DOWN FOR LAMP AND BALLAST SERVICING) OBSERVATION WINDOW C/W LIGHT TIGHT COVER DUAL SIDEWALL MOUNTED AIR HANDLER/HEAT EXCHANGER PLENUMS -FRESH AIR (2) MAIN COOLING COIL...
Open the catalog to page 11All Meditech catalogs and technical brochures
-
All purpose equipment
1 Pages
-
Blood Bank Tube sealer
1 Pages
-
Solar DC Compressor
3 Pages
-
glass bead sterilizer
1 Pages
-
walk in cooler for blood bank
18 Pages
-
thermo hygrostat chamber
10 Pages
-
stability chamber
10 Pages
-
photostability chamber
9 Pages
-
Humidity Chamber
10 Pages
-
Freezer thaw chamber
9 Pages
-
cold room
10 Pages
-
cold room for blood bank
18 Pages
-
co2 incubator
15 Pages
-
BOD Incubator
10 Pages
-
Bacteriological Incubator
4 Pages
-
solar ice lined refrigerator
7 Pages
-
Blood Donor Couch
1 Pages
-
platelet incubator agitator
3 Pages
-
Biomedical lab Refrigerator
4 Pages
-
Biomedical lab Refrigerator
4 Pages
-
Blood Donor Coach Chair
1 Pages
-
Incubator
2 Pages
-
Meditech Blood Bank Equipments
41 Pages
-
Incubator Meditech
2 Pages
-
Phlebotomy Chair Meditech
1 Pages
-
Blood Donor Chair Meditech
1 Pages
-
SS Vacuum Chamber for drying
1 Pages
-
SS Vacuum Degassing Chamber
1 Pages
-
pack vac leak detector
2 Pages
-
heated vacuum oven
1 Pages
-
acrylic vacuum chamber cube
1 Pages
-
plasma-expressor-automatic
1 Pages
-
Plasma Thawing Bath
2 Pages
-
Platelet Agitator
3 Pages
-
Laminar Air Flow_horizontal
1 Pages
-
Blood-bank-Refrigerator
18 Pages
-
Spirometer
1 Pages
-
Varnishing Outfit
1 Pages
-
Blood Collection Monitor
4 Pages
-
Blood Donor Chair
1 Pages
-
Elisa Plate Analyser
2 Pages
-
Seed Storage Chamber
9 Pages
-
insect rearing chamber
2 Pages
-
MTCR 60
6 Pages
-
MTCR 120
6 Pages
-
MTCR 180
6 Pages
-
MTPS432
5 Pages
-
MTPS360
5 Pages
-
MTPS288
5 Pages
-
MTPS216
5 Pages
-
MTPS144
5 Pages
-
MTPS72
5 Pages
-
MBDW120
11 Pages
-
MBDW80
11 Pages
-
MPGC20
7 Pages
-
MTR30
3 Pages
-
MTR26
3 Pages
-
ME7-2
3 Pages
-
ME8
8 Pages
-
MTAC26
8 Pages
-
Plant Growth Chamber ME8
8 Pages
-
Plant Growth Chamber MTBDR16
3 Pages
-
Arabidopsis Chamber MTAC60
7 Pages
-
Arabidopsis Chamber MTAC40
7 Pages