The document provides detailed information about the Digital Student Physiograph, MTDSP, Physiopac, and Digital Polygraph-Physiograph, which are tools designed for teaching experimental physiology and pharmacology on human and animal subjects.
Features
  • RR analysis and wave integration capabilities.
  • Four-channel lie detector functionality.
  • Patient database management and real-time data storage.
  • Time and voltage marking on individual channels.
Experiments
  • Volumetric changes and blood pressure (invasive and non-invasive).
  • Isometric force and isotonic fine movement studies.
  • Recording of ECG, EEG, EMG, ENG, GSR, and more.
  • Respiration and temperature monitoring.
  • Plethysmograph for pulse and heart rate analysis.
Lessons
  • EEG: Record and analyze EEG signals, examining changes during relaxation and attention.
  • EMG: Record muscle contractions and compare signals from different muscle groups.
  • ECG: Study ECG leads and perform measurements of heart wave components.
  • ENG: Record eye movements and perform saccade and gaze tests.
  • Pulse & Plethysmography: Measure pulse non-invasively and study the heart's mechanical action.
Additional Functionalities
  • Respiration: Record respiratory efforts and airflow using chest expansion and thermister methods.
  • Polygraph: Record standard polygraph measurements and study physiological changes related to truth-telling.
  • Reaction Time: Measure response times to auditory stimuli.
  • Biofeedback: Monitor heart rate and GSR to control visual feedback.
  • Spirometry: Perform pulmonary function tests.
  • Heart Sounds: Record and analyze phonocardiograms.
  • Amphibian Experiments: Conduct various muscle contraction experiments using amphibian models.
See more

Catalog excerpts

Physiopac Digital Polygraph-Physiograph-1

Digital Student Physiograph, MTDS]Physiopac Digital Polygraph-Physiograph Features ❖Features ❖RR analysis ❖Merging of Waves ❖Integration of Waves ❖Four channel Lie-Detector ❖Patient Database information ❖Real Time data storage & review facilities ❖Experiments on Animal & Human Subjects ❖Time & Voltage Marking on individual channel For Teaching Experimental Phsiology & Pharmacology on Human & Animals Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.com

 Open the catalog to page 1
Physiopac Digital Polygraph-Physiograph-2

Digital Student Physiograph, MTDS]Physiopac Digital Polygraph-Physiograph Experiments 4. Isotonic Fine Movement 8. Plethysmograph ( Pulse, Heart rate etc) Report Format Blood Pressure l.essions Electroencephalogram (EEG) : Record and View EEG from any location. See how EEG signal changes in Relaxation, Attention and use filters to examine frequency band ( Alpha, Beta, Delta & Theta) Muscle contarction (EMG): Record and View EMG signal with surface electrodes from different location. See raw and integrated real time EMG data. Simultaneously compare the EMG signal from one muscle group...

 Open the catalog to page 2
Physiopac Digital Polygraph-Physiograph-3

Digital Student Physiograph, MTDSP Physiopac Digital Polygraph-Physiograph Respiration: Record and review Respiratory efforts and relative air flow. Respiration is measured by recording chest expansion and contraction. Air flow is indirectly recorded by using a thermister placed next to the nose. Examine the time relationship between chest motion and air flow Polygraph: Record and review the standard Polygraph measurements e.g. Respiration, Galvic Skin Response and pulse rate. The timing of each question is recorded by a marker on the graph. Study Physiological Changes on telling ( or not telling...

 Open the catalog to page 3
Physiopac Digital Polygraph-Physiograph-4

Physiopac Digital Polygraph-Physiograph Technical Specifications Number of Channels Amplifier A/D Conversion Sampling Rate Sensitivity Low Pass Filter High Pass Filter Sweep Speed Notch Filter Input Impendence CMRR Standard Accessories ECG electrodes EEG electrode Bio-Potential Junction Box ECG Junction Box EMG disc electrodes Ground electrode EEG Paste ECG Jelly Communication Cable BP Cuff Operating Manual Software Transducers Pulse Transducer Respiration T ransducer (belt type) Respiration Transducer (ThermistorType) Temperature Transducer GSR Transducer Phono-Cardiogram Transducer Pressure...

 Open the catalog to page 4

All Meditech catalogs and technical brochures

  1. cold room

    10  Pages

  2. co2 incubator

    15  Pages

  3. BOD Incubator

    10  Pages

  4. Incubator

    2  Pages

  5. Spirometer

    1  Page

  6. MTCR 60

    6  Pages

  7. MTCR 120

    6  Pages

  8. MTCR 180

    6  Pages

  9. MTPS432

    5  Pages

  10. MTPS360

    5  Pages

  11. MTPS288

    5  Pages

  12. MTPS216

    5  Pages

  13. MTPS144

    5  Pages

  14. MTPS72

    5  Pages

  15. MBDW120

    11  Pages

  16. MBDW80

    11  Pages

  17. MBDW40

    11  Pages

  18. MPGC20

    7  Pages

  19. MTR30

    3  Pages

  20. MTR26

    3  Pages

  21. ME7-2

    3  Pages

  22. ME8

    8  Pages

  23. MTAC26

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.