Plant Growth Chamber ME8 Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.com
Open the catalog to page 1Product Overview/Applications 1E8 is a highly customizable plant growth chamber capable of achieving extreme conditions of temperature, lighting levels, and humidity. The product is well suited for research applications requiring a high level of control in a relatively small footprint. In addition to customizable environmental control parameters, options are also available for growth height, gas levels, and a variety of refrigeration configurations. The ME8 offers a minimum growth height of 46” (1170mm) in an 8 ft2 (0.7m3) growth area. Please consult Meditech for your specific requirements.....
Open the catalog to page 2Plant Growth Chamber ME8 Meditech 7 inch Touch Screen Controller 2.0 Construction: (Note: All dimensions are nominal) 2.1 Exterior Dimensions: 71.25”W x 29.5”D x 76.25”H (1810 mmW x 750mmD x 1935mmH). 2.2 Interior Dimensions: 49”W x 24.25”D x 70”H (1245mmW x 620mmD x 1780mmH). 2.3 Growth Area: 8ft² (0.74m²). 2.4 Growth Capacity: 32ft³ (900 liters). 2.5 Floor: Perforated aluminum channel floor for uniform upward air flow – Uni-floor 2.6 Growth Height: 46” (1180mm) from Uni-floor to Light right in the UP position. 2.7 Exterior Finish: Blue-green enamel baked on patterned aluminum. 2.8 Interior...
Open the catalog to page 3Plant Growth Chamber ME8 5.2 Heat Exchanger Coil(s): 5.3 Valve: 5.4 Refrigerant: 5.5 Monitoring: Cabinet is supplied with an air-cooled condensing unit with hot gas bypass system for continuous compressor operation, extended compressor life and close temperature control. Condensing unit is located in machine compartment. Copper-tubed construction. Electronic modulating valve that smoothly regulates the heating and cooling functions of the chamber. Refrigeration system is charged with CFC-free refrigerant. a) Refrigeration system operation is monitored by the control system, including visual and...
Open the catalog to page 4Plant Growth Chamber 8 TEMPERATURE Low Temperature Operation Surge protection and uninterrupted power supply, on controller only, for continuous operation of the controller during power interruptions, duration of the UPS is approx. 15 minutes. (Consult factory for increased duration, if required.) (No fresh air below 4°C.) A defrost cycle will occur resulting in a temperature increase for temperatures set below 10°C lights ON, or 4°C lights OFF. Temperature deviations and defrost time are dependant on chamber operating temperature. During the defrost cycle, the lights will be turned off. Specified...
Open the catalog to page 5Bypass Dehumidification Compact pump and reservoir for spray nozzles. Order this option with SNH if the minimum 60 psi (4.2 bar) water pressure is not available. Supplies pressurized water for up to 12 nozzles Pressure reservoir at downstream chambers. Must be ordered for all downstream chambers fed from CPSNH. A precisely controlled volume of chamber air bypasses the heat exchanger by means of a proportionally controlled air damper. Using excess capacity in the refrigeration system, moisture is removed from the remaining air by cooling and reheating. Note: 1. Reduces growth height by 3" (75mm). 2....
Open the catalog to page 6RAC Remote Outdoor Remote outdoor air-cooled condenser complete with all weather Air-Cooled Condenser housing, low ambient operation controls and low noise level operation. Remote location (up to 50’ [15m] combined horizontal and vertical distance) of condenser only - compressor, receiver and other refrigeration components remain in cabinet machine compartment. Order “RACH" for climates with ambient temperatures from +35°C to +45°C for extended periods. Electrical: 60Hz - 2O8-23O-10-6OHz-3 wire plus ground, 50Hz - 22O-10-5OHz-2 wire plus ground. Consult factory for either amperages...
Open the catalog to page 7FRONT ELEVATION PLAN VIEW Head Office: No.6 President Terrace. Takli Road, Dwarka. Nashik-422011 Phone:0253 - 6418632 Email: [email protected]. Website: www.newmeditech.com
Open the catalog to page 81 Page
2 Pages
1 Page
1 Page
3 Pages
1 Page
18 Pages
10 Pages
10 Pages
9 Pages
10 Pages
9 Pages
10 Pages
18 Pages
15 Pages
10 Pages
4 Pages
7 Pages
1 Page
3 Pages
4 Pages
4 Pages
1 Page
2 Pages
41 Pages
2 Pages
2 Pages
3 Pages
18 Pages
1 Page
1 Page
4 Pages
1 Page
2 Pages
9 Pages
2 Pages
6 Pages
6 Pages
6 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
5 Pages
11 Pages
11 Pages
11 Pages
7 Pages
3 Pages
3 Pages
3 Pages
8 Pages
8 Pages
3 Pages
7 Pages
7 Pages